Why are wall wind zones reported as Zero when I review the Zone Loads for wind load cases?

Tekla Structural Designer 2022 - 2026 Zero Zone Loads wind zone wind
2026
Tekla Structural Designer
2025
Tekla Structural Designer
2024
Tekla Structural Designer
2023
Tekla Structural Designer
2022
Tekla Structural Designer
Environment
British Standard
Eurocode

Issue


Why are my wall wind zones reported as Zero?

 

Image
2017_03_30_12_08_321.png

Resolution


In the screenshot below, the Load ribbon > Wind Load group > Wind Wizard... command has defined the Ground level as  -0.5m. Wind is ignored below this value.

 

Image
2017_03_30_12_09_032.png




If we review the Model ribbon > Levels group > Construction Levels command, the levels in the screenshot below are between -6m and 0m.

 

Image
2017_03_30_12_09_463.png



The wind load is only applied beginning at the height of -0.5m as defined in the Wind Wizard.

Hence, the Zero locations are where the model falls below the Ground level of -0.5m where wind is ignored.

 

Image
2017_03_30_12_10_114.png