Manage alignment preferences in Quantm to define the geometric standards, design parameters, and cost constraints for your project.
- To open the Preference Settings, from the Quantm menu in the top-left corner, select Preference Settings.
- Select the Alignment tab.
- Modify the following settings:
-
Enter the Display width factor so that alignments can be drawn wider in the Plan view window than they actually are.
-
In V:H Ratio, select the ratio of vertical to horizontal scale on displays of the alignment in the Profile view window.
CAUTION: If you select Auto, the zoom tools do not work in the Profile view window. -
Set the Cross Section Interval Setting to be displayed for result processing.
-
Manage Alignment Cost Settings:
-
Show or hide the Alignment cost.
-
In Alignment %, show costs as percentage savings only. One alignment is used as a benchmark and other alignment costs are displayed as a percentage of the benchmarks alignment cost. A positive cost indicates the alignment is more expensive than the benchmark alignment. A negative cost indicates the alignment is cheaper than the benchmark. To set an alignment as a benchmark, right-click on the alignment in the Alignment Comparison window to access the shortcut menu and then select Benchmark.
-
Include Fixed cost in the cost of the alignment and display the fixed cost in the Alignment Summary window.
-
Select if you want to recost alignments automatically when they are edited. Clear the Automatically recost checkbox on edit checkbox if you prefer to make numerous edits and then recost manually. A recost icon appears when an alignment needs recosting.
-
Select if you want to display CO2 values in the reports.
-
-
Manage Height Defined Structures.
-
If you do not want any height defined structures, select the checkboxes below the Height Defined Structures heading.
-
-