Skip to main content

Scenario errors

Modified: 22 Oct 2026 Quantm Help

The Trimble Quantm Alignment Planning software regularly checks that the inputs and constraints for a scenario are acceptable. Any errors are shown in a message window.

Note: Before submitting a job to be optimized resolve all scenario errors because they can have a negative effect on generated alignments.

The following table lists the errors that may appear:

Error Description
Small zones If a zone is too small, it has a negligible chance of being detected by the Quantm Optimizer. Zones of less than 100 m squared (120 yd squared) are flagged. Small zones should be deleted, made inactive, or enlarged; and/or clusters of small zones should be consolidated into a larger zone.
Zone boundaries intersecting themselves A zone boundary that forms a figure "8" or crosses itself in any other way can create questions about what is inside and what is outside the zone. Adjust boundaries to ensure that each zone is a single continuous shape.
Duplicate points Identical points in a feature or zone boundary are unnecessary and can create problems during optimization. To calculate where an alignment crosses a zone boundary or a linear feature, the system calculates the equation for each line segment. If there are duplicate points, the line segment has zero length, and "divide by zero" errors are generated. There is an option to remove the extra points.
Insufficient points Zones defined with fewer than 3 points, and features defined with fewer than 2 points, do not constitute a closed shape or line. Remove or adjust such objects.
Unreasonable parameters Input parameters are checked to see whether they fall within acceptable limits. Correct excessively large or small values.

When you create a zone or feature, the following errors may also appear:

Error Description
Too many points A point is necessary only where the boundary or feature changes direction. Zones and features are over defined if there are too many points along a continuous straight boundary or line. The extra points slow the Quantm optimizer and the error checking process. To achieve the same results more quickly, remove unnecessary co-linear points.
Zone/Feature outside the DTM Zones and features situated entirely outside the DTM are unnecessary and slow down the Quantm optimizer. Trimble recommends that you delete these objects or make them inactive.
Zone/Feature probably outside the DTM All points on the zone boundary or feature are outside the DTM, but the zone boundary or feature is close enough to the DTM that the zone boundary or feature may still cross the DTM between points. Check the object before deleting it or rendering it inactive.

The options for correcting errors within data are as follows:

Option for correcting the error Description
Fix All Corrects errors in all objects in list. This may remove objects outside the DTM extents or remove duplicate vertices within objects, etc.
Fix Corrects errors in selected object in list. This may remove objects outside the DTM extents or remove duplicate vertices within objects, etc.
Deactivate All Converts all objects in the list to an ignored object, which will not affect optimization.
Deactivate Converts the listed object to an ignored object, which will not affect optimization.
View Zooms the Plan view to the extent of the objects containing the errors.
Recheck Runs the Data Validation command again to recheck the data to ensure data errors have been corrected.
Write Writes the list of errors with the location of the first x,y coordinate of the object to a data file.
OK Accepts changes to objects.
Submit

Table of Contents