Change element segmentation

Modified: 25 Jun 2026 Stabicad
Stabicad
Stabicad

Divide long duct, pipe, or conduit runs into sections based on manufacturer lengths or manual specifications.

With the Change segmentation function, you can convert a continuous system run into discrete segments including the necessary connector pieces (such as sleeves or couplings). This ensures that your Bill of Materials (BOM) reflects the actual number of pipes or ducts required for purchase based on standard delivery lengths.

  1. Open the relevant palette, go to the Modify tab, and click Change segmentation.
  2. In the drawing, select the elements you want to segment and indicate from which side of the run the segmentation should begin.

    The Element Segmentation dialog opens.

  3. Choose one of the segmentation methods:
    • Adopt segment lengths of selected elements - Use the manufacturer-specified lengths defined in the product line for all selected elements.
    • Adopt segment lengths of selected elements and for elements which have no segment length use this length - Use manufacturer lengths where available and a manually specified value for other elements.
    • Use a new segment length for all selected elements - Overried all current data with a new, manually specified segment length.
  4. Choose how to apply the changes to existing segments:
    • To replace the current segmentation, select Override existing segmentation.
    • To add new segments while keeping the existing segmentation, do not select Override existing segmentation.
  5. Click OK.
Stabicad now divides the system elements into the specified lengths and inserts the correct connectors into the drawing and the material report.