Use the Automatic Placement feature to fill entire floors with air terminals, lightning fixtures, sprinklers, and other ceiling-mounted elements in one run — instead of placing each symbol room by room. You define your rooms, set a placement rule once, and Stabicad distributes the symbols across every selected space automatically.
With rooms we mean spaces — room boundaries are defined in Space Management.
Availability: Automatic Placement is available in Stabicad 26.08 and later and in Stabicad for AutoCAD on AutoCAD 2025 and AutoCAD 2026. AutoCAD 2023 and 2024 are not supported, nor planned to be supported in the future. AutoCAD 2027 and Intellicad are currently not supported. This feature is not available in Stabicad for Revit.
Automatic Placement supports two rule types described in the following table:
| Ventilation based rules | Generic rules (generic placement) | |
|---|---|---|
| Use for placing | Air terminals (ventilation) | Any other trade — lighting fixtures, sprinklers, sockets, and other ceiling-mounted content |
| How many symbols? | Calculated from room volume, air exchange rate, and volume flow rate | You set the Entity Count on the room. |
| Create preset | Ventilation rule | Generic rule |
| Rule-specific properties | Volume flow rate (%), Air exchange rate per hour | None — no ventilation calculation fields |
Before you start
-
Open a drawing that is registered in StabiBASE.
-
Define your rooms using Space Management.
For more information, see section "Add a room and define room properties" below.
Ensure that you set the following values properly:
-
In Edit Room Properties (or in Add Room Properties when drawing a new room), set values for Height and Ceiling height, and confirm the Volume value.
Optional: Set the default room height values in , for example, Height 3000 mm (default 3000 mm) and Ceiling height 3000 mm (default 2700 mm).
-
For generic rules only: Set the Entity Count value greater than 0 on each room you want to fill. If the Entity Count value is 0, no symbols are placed.
-
Add a room and define room properties
Create a room to place content automatically using rule-based grids. You can create rooms using Space Management.
- From StabiBASE, open a drawing.
- Add a room and define the room properties:
- Click OK to save.
Stabicad draws the room boundaries and stores the room data.
For more information, see the following sections:
Start Automatic Placement
Start the Automatic Placement feature to create and add the rules.
The Automatic Placement window opens. If no rules are active yet, the text ADD OR CREATE A RULE is displayed with options to add a rule from the library or create a new one.
Create a ventilation rule (air terminals)
Use this path when you want to place air terminals and let Stabicad calculate how many to place.
The rule is saved to the drawing rule set.
Create a generic rule (generic placement)
Use this path for lighting, sprinklers, sockets, or any non-ventilation content distributed on a ceiling grid.
NOTE: Ensure each linked room has an Entity Count greater than 0 before you apply the rule.
Grid layout method
When creating a new rule, you must select the Grid layout method. Each rule uses the grid layout method to position symbols inside the room. The method controls how symbols are spaced relative to the room walls.
| Method | When to use | Behavior |
|---|---|---|
| Uniform | Rectangular rooms where wall clearance should equal the spacing between symbols | Symbols are placed so that the distance from each wall equals the distance between symbols. |
| Standard ½ | Rectangular rooms where you want symbols set halfway between the wall and the first grid line | The distance from each wall is half the spacing between symbols. |
| Default | Any room shape, including non-rectangular rooms | Stabicad keeps symbols at a minimum distance from the walls and distributes them across the room. Use this method when the room is not a simple rectangle. |
Notes
- Uniform and Standard ½ apply to rectangular rooms. For other room shapes, Stabicad uses the Default method automatically.
-
Uniform and Standard ½ methods only know how to work with simple rectangular rooms, like with exactly four walls, all corners at 90°. If the room is any other shape, the service switches to the Default method for that room.
-
When the switch to Default happens, you get the Default behavior. In particular, the Min. distance to wall setting starts affecting, and the room outline is first pulled inward by that distance, and outlets are then spread inside that smaller area.
- Rectangular room + Uniform/Standard ½: Min. distance to wall is ignored and the wall gap comes purely from the spacing formula.
- Non-rectangular room + Uniform/Standard ½: The grid layout method selection is ignored and the result looks exactly as if the user had selected the Default method, including the Min. distance to wall gap.
- For ventilation rules, the number of symbols is determined by the ventilation parameters — not by Entity Count. The grid method only controls where those symbols are placed.
- For generic rules, Entity Count sets how many symbols are placed; the grid layout method controls their positions.
Add a rule from the rule library
Instead of creating a rule from scratch, you can pick one from the drawing rule set library.
- In the Automatic Placement window, click Rule manager (gear icon) or Add rule from list.
- Filter by Ventilation based rules or Generic rules.
- Select one or more rules and click Add selected rules.
The selected rules appear as cards in the main Automatic Placement window.

Edit or delete a rule
You can edit or delete rules in the Rule manager or in the Automatic Placement window.
- In Rule manager table, click
Edit to open the Edit rule dialog, then select Update or Delete. - In the Automatic Placement window, use the
Edit or
Delete controls on each rule card.
Link rooms to a rule
Before you can use a rule, you need to link it to a room.
Apply rules to the model
When you have configured your rules and linked the rules to the desired rooms, you can apply your rules to the model.
Troubleshooting
| Issue | What to check |
|---|---|
| Nothing placed (generic rule) | Entity Count is 0 on the room. In Space Management, go to the Change tab and in Edit room line, set Entity Count greater than 0. |
| Nothing placed (ventilation rule) | Room Volume is missing or zero. Check Height and Ceiling height. Review Volume flow rate and Air exchange rate per hour. |
| Apply rules to model is disabled | The content referenced by a rule was deleted from the drawing. Open the rule, click Choose content, and reselect the symbol or article. |
| Feature not visible | Confirm you are using Stabicad 26.08 and later and in Stabicad for AutoCAD on AutoCAD 2025 and AutoCAD 2026 with a StabiBASE-registered drawing. Automatic Placement is not available in Revit. |
| Grid looks wrong in an irregular room | Use Default as the grid layout method. Uniform and Standard ½ are intended for rectangular rooms. |
| Placement takes a long time | Expected for large drawings or many rooms. Wait for the progress message to clear. |