Electrical installation drawing settings

Modified: 29 Jun 2026 Stabicad
Stabicad
Stabicad

Use the light fixture automation settings to determine if fixture dimensions should automatically update based on their assigned function codes.

Symbol properties

Setting Description
Text height Set the size that the listed symbol properties will have in the drawing
Color Set the color that the listed symbol properties will have in the drawing.
Visibility Set whether the listed symbol properties are visible in the drawing.

Symbol insertion

Setting Description
Activate symbol layer after insertion Specify whether the layer the symbol is placed on is automatically activated after placing the symbol.
Always show annotations of a vertical composite from top to bottom Use this setting to specify the order of the annotations when placing a vertical composite.
Annotation offset when placing a vertical composite Use this setting to specify whether you would like to place the annotations closer to each other or further away from each other when placing a vertical composite.

NOTE: For nested symbols in Revit, if this offset fails to apply, the family group structure may need to be recreated in the Family Editor.

Automatically activate ceiling plan when inserting a symbol When set to Yes, the ceiling plan view is automatically activated when you place a symbol, in case you specified in the symbol inserter dialog the ceiling as a host. Automatically activating the ceiling plan can cause performance problems in large projects.
Automatically repeat insertion Select if you want to be automatically allowed to place another symbol and keep the insert dialog open.
Change function code when inserting additive symbol If this option is set to Yes, when you add an additive symbol to for example a light fixture, the light fixture's function code changes to that of the additive.
Default coding for security symbols Choose which of the available coding options is the default when placing security symbols.
Distance from reference point on the wall Set the default Y offset for CAD symbols placed on the wall.
Distance from symbols to wall Specify the distance from the wall the symbol is placed at.
Place families "hosted" by default Select whether the default hosting option is Not hosted (setting No) or Face based (setting Yes).
Immediately apply changes when inserting a symbol When set to Yes, the parameter values of the symbols are filled in right after you inserted the symbol. If set to No, the parameter values of the placed symbols are filled in when you close the symbol insertion dialog. Setting it to No will improve the performance in case of placing the same symbol several times without closing the dialog.
Modify properties Whether the insert dialog where you can adjust the symbol properties is displayed when placing the symbol.
Place tags when inserting symbol Specify whether tags are automatically placed along with the symbols.
Position attributes Specify whether you can manually position the attributes, like the circuit number, when placing the symbols.
Preferred mounting Specify whether either Recessed or Surface mounted is the default variant when placing symbols.
Remember last filled in property values Specify whether the properties you enter when placing a symbol, like the panel or circuit number, are remembered next time you place it.
Scale manual Specify whether you can manually set the scale factor on X and Y axes when placing the symbol.
Use coding "loop-group-sequence number" for fire protection symbols Specify whether this coding is used when placing fire protection symbols.
Use the top element of a vertical composite as the reference for the mounting height Specify if, when placing a vertical composite, you would like to use either the top or the middle of the vertical composite as a reference point for the mounting height. The middle element is normally used as a reference point for the mounting height.

Manage installation

Setting Description
Apply simultaneity factor of circuit with subpanel to Apparent power of subpanel or Expected power of subpanel.
Automatically generate circuit descriptions
Default class type
Default percentage spare power for a panel
Pass panel spare power on to above circuit
Saving installation saves whole drawing
Show power module Whether to make the power module available. That is, when activated, the power module symbols are displayed in the list of protections.
VVA of sub panel qualifying Ib Whether the total expected power (VVA) of sub panel qualifying Ib is made effective.
Simultaneity Set the simultaneity factor's values for the electrical items in the list. The simultaneity factor is the factor used to multiply the sum of all devices load by in order to establish the amount of load a system should be rated for. The premise is that most likely not all devices are turned on at the same time.

Panel schedule

Setting Description
Draw number of safety levels
Orientation vertical
Power totals below overview
Right justify power columns
Visibility Whether to draw different panel schedule elements (for example cable symbols, subcircuits, etc.) or fill in different values (for example expected power or phase distribution) when drawing.
Color circuit in table grid
Color of texts in panel schedule
Color panel name
Color panel outline
Color of protection properties
Color rail and circuit
Color table grid
Text height other text
Text height panel name
Text height protection properties
Bottom margin panel outline
Center text of column ‘description’
Distance between circuits
Distance panel to table grid
Margin between outline and main rail
Position panel outline
Top margin panel outline
Width simultaneitycolumns of simultaneity factor
Width of the amount columns
Width of the description
Width of the power columns

Block schedule

Setting Description
Block height
Block width
Horizontal block distance
Vertical block distance
Visibility Whether to automatically activate the listed settings when drawing the block schedule.
Color of texts in panel schedule
Text height other text

Security schedule

Setting Description
Cable data Set the maximum length (number of characters) for the cable data.
Distance between symbols
Power supply Set the maximum length (number of characters) for the power supply specifications.
Width security panel

Fire protection schedule

Setting Description
Cable data Set the maximum length (number of characters) for the cable data.
Distance between symbols
Maximum number of symbols on line
Network Input Text/Network Output Text
Power supply Set the maximum length (number of characters) for the power supply specifications.
Show Circuit
Show Circuit Sequence Number
Show Coding 1/Show Coding 2
Show Hardware Number
Show Indicator Number
Show Loop Sequence Number
Show Zone
Width security panel

Cable system

Setting Description
Number of decimals length pluggable cable
Show extensive cable annotation
Show pluggable locking clips on report
Show pluggable tees on report
Connect extra cable to symbol on height difference Specify whether two symbols are connected via a cable that goes up from a symbol, then sideways and down to the other symbol. The extra cable is the section that goes up and down.
Default cable height Specify from a drop-down menu which of the Cable duct height, Ceiling height, Reduced ceiling height or Other height values cables should adopt. This elevation is used when either drawing a cable or drawing it between two symbols.
Cable duct height Specify the default elevation at which the cable duct is mounted.
Ceiling height Specify the default elevation of the ceiling.
Reduced ceiling height Specify the default elevation of the reduced ceiling.
Other height Specify a custom elevation at which cables are mounted.

Change symbol properties

Setting Description
Change length and width light fixture automatically after assigning light fixture code
Submit