Configure sewerage and drainage system settings to manage annotation styles, fitting representations, slope formatting, and graphical display properties for pipes, insulation, and fire protection valves.

Attributes and texts

Setting Description
Color of text in pipes
Color other attributes
Height annotation text
Height of text in pipes
Height other attributes
Include insulation thickness in the elevation annotation Whether to count the insulation thickness in the pipe's elevation value displayed in the annotation.

Drawing settings

Setting Description
Draw 1L flexible pipe as polyline Whether to draw the 1L flexible pipes as polylines.
Flow direction equals drawing direction Whether to place the branches of flowing tees in the drawing direction. This supports two ways of drawing: when set to Yes, you can draw from the drains to the central sewerage system, when set to No, the other way around.
Height above floor
Ceiling height
Suffix for slope annotations Set the measurement unit to follow the slope value in annotations (e.g. mm/m).
Prefix for slope annotations Define how the slope will be named in annotations.
Shorten pipes when inserting fitting/equipment Whether to shorten ducts when inserting fitting/equipment in the sewer system. That is, the duct will become shorter by half the length of the element's body, without connections.
Tolerance with connecting pipe (degrees) Set the accepted tolerance from linearity, in degrees, when connecting two ducts.
Horizontal 90° bend Choose how to display a horizontal 90° bend, that is either as 2 bends 45° or as a Bend 90°.
Horizontal 90° branch Choose how to display a horizontal 90° branch, that is either as Tee 45° and bend 45° or as a Tee 90°.
Horizontal reducing branch Choose how to display a horizontal reduced branch, that is either with a Separate reducer or a Reducing tee.
Reducing 90° bend Choose how to display a reduced 90° bend, that is either with Bend and reducer or a Reducing bend. The selected option will be used as the first solution in node solver function.
Vertical 90° bend Choose how to display a vertical 90° bend, that is either as 2 bends 45° or as a Bend 90°.
Vertical 90° branch Choose how to display a vertical 90° branch, that is either as Tee 45° and bend 45° or as a Tee 90°.
Vertical reducing branch Choose how to display a vertical reduced branch, that is either with a Separate reducer or a Reducing tee.

Visualization

Setting Description
Arrow angle Set a different floor arrow angle for sewerage than for piping, per project.
Color of insulation for visualization Casing Set the color of the casing representation for a pipe. It only applies when the visualization value in the Edit Insulation Properties dialog is set to Casing.
Color of dashed lines Set the color of the dashed lines which display the duct below when two ducts are overlapping at different elevations.
Color of equipment
Color of insulated pipe for visualization Casing This setting allows you to define a color for insulated pipes when their visualization mode is Casing.
Color of vertical pipes
Draw fittings as individual elements
Drawing method rectangular fire protection valve
Drawing method round fire protection valve
Scale of vertical pipe at 1:1/Scale of vertical pipe at 1:100/Scale of vertical pipe at 1:20/Scale of vertical pipe at 1:50
Show fittings in single line systems through perpendicular lines When drawing in single line, you don't see fitting ends delimited from the straight tracks. Set this on Yes to add small dashes, perpendicular on the system track, which show fittings clearly delimited.
Size of arrow at 1:1/Size of arrow at 1:100/Size of arrow at 1:20/Size of arrow at 1:50

Breaks

Setting Description
Break type round
Break type round horizontal
Break type round vertical
Length of break round

Specific settings

Setting Description
Round cutting length to (mm)
Submit