Meshing issues tend to be caused when the area being meshed ends up with really narrow strips of slab, for example when the slab edge ends up just outside the edge of a column. The 2D elements created within such strips will be of poor quality. When this occurs appropriate warning messages are displayed under the Meshing heading in the Status window.

On the Meshing page in the Analysis Settings dialog certain meshing tolerance controls can be adjusted when required to solve these type of issue.
The model shown below has various challenging situations which are discussed in the sections below. In each of these cases changing the meshing tolerance controls will have an impact.
When you make use of the meshing tolerance controls a (typically small) area of the slab is removed from the mesh. Any load within the removed area is not considered in the FE analysis. Entering too large a value can result in a significant area of slab being removed - potentially leading to a load imbalance.
1. Column face close to parallel slab edge
In this example the slab edge is positioned 50mm outside the column face. The view above left shows the analysis model you would get when the Column boundary to slab edge merging distance is < 50mm. The view above right shows the model you get if the merging distance is set to 50mm or above. The column corner nodes merge (move to) the slab edge eliminating the narrow strip.
The simplified analysis model avoids mesh quality warnings and gives almost identical results in terms of column transfer forces and slab design.
2. Column face close to inclined slab edge

In this example the slab edge sits 10mm outside the column upper left corner. The view above left shows analysis model where a very poor quality element runs past the corner, (you would end up with this model if the Column boundary to slab edge merging distance were to be set less than 10mm). The view above right shows the model you get if the merging distance is set to 10mm or above. One column corner node merges (moves to) the slab edge eliminating the narrowest part of strip.
The simplified analysis model avoids mesh quality warnings and gives almost identical results in terms of column transfer forces and slab design.
3. Column close to multiple non-parallel slab edges

slab edge sits 10mm outside the column upper left corner
This is just another variation on positions 1 and 2. Again the slab edge sits about 10mm outside the column edges at the closest points.The view above left shows analysis model you would end up with if the Column boundary to slab edge merging distance were to be set less than this distance. The view above right shows the model you get when you increase the Column boundary to slab edge to > 10mm - meshing is simplified avoiding mesh quality warnings and almost identical results in terms of column transfer forces and slab design are obtained.
4. Opening near slab edge
In the following examples merging will make things better, but the reality is that a slab will never be cast with thin isolated strips at the edge - you cannot effectively reinforce a 50 to 100mm wide strip of slab. In all these the ideal solution is that the modelling should reflect the reality of realistic minimum edge distances.
An opening is defined approximately 20mm from the slab edge. The effect is the same as at the column cut-out boundary - above on the right shows how with the Opening to slab edge merge distance set to 50mm the opening corners move to the slab edge. This creates a better analysis model.
5. Opening near wall inserted along slab edge
This is basically the same as the previous situation except that a wall happens to be defined along the edge. In such cases the user is often tempted to extend the opening into the physical width of the wall but does not extend it right to the wall insertion line.
There are pros and cons to both models. On the left the narrow meshed strip of slab can give mesh quality warnings and errors. On the right the Opening to slab edge merge distance has been increased (to a value greater than the narrow strip width) and the slab mesh is better. The revised model relies a bit more heavily on the wall beam to transfer moments, however the overall minor axis moment transferred to the wall only drops by a slight amount.
6. Circular opening near slab edge
Above left shows the sort of meshing that will occur when a circular opening is created near to the slab edge. Above center shows an example where closest point on the circle is merged to edge. The meshing looks a bit better but this is still not a great model because you will get strange local results at the connecting node. On the right where the Opening to slab edge merge distance is set to 100mm the edge gets completely broken - this is probably the best model.
7. Closely spaced openings
You can easily model circular and rectangular slab openings, but when it comes to other multi-sided openings a little more care is required. These are typically modelled by abutting rectangular openings against each other and problems can generally be avoided by adjusting the openings so that they overlap slightly.
The example below shows meshing when a narrow (unbuildable?) strip of slab is left between openings.

To avoid having to manually adjust the openings to eliminate this strip you could instead increase the Opening to slab edge merge distance to a value greater than the narrow strip width.

8. Opening near column

In both these cases, to avoid having to adjust the openings so that they overlap the column boundaries, you could instead ensure the Opening to slab edge merge distance is greater than the narrow strip between the opening and column.

9. Opening near wall with slab on other side
In this case the opening is defined with an edge that is approximately 4mm from the insertion line of the wall. With the Hardpoint to edge distance tolerance (slabs) at the default of 5mm this creates a model that is poorly connected along the edge of the opening.

The wall mesh node highlighted in red is not included in the slab meshing (because it is just 4mm away from the edge). The 2 slab mesh nodes highlighted in blue to either side of this are not directly connected to the wall.
If the hard point distance is reduced to 1mm then the model changes as shown below, the node marked in red above is now included in the slab mesh so the adjacent nodes have a better connection to the wall.
However, the best model would be obtained if the opening edge got exactly aligned with the wall, this can actually be quite hard to achieve in the manual positioning of openings. A workaround at present is to force a slab mesh boundary edge along the line of the wall by making the slab on one side slightly different to the slab on the other. This would result in an improved mesh adjacent to the opening edge as shown below.