All Heights Building Geometry (ASCE 7 Wind Wizard)

Modified: 11 Jun 2024 Tekla Structural Designer 2025
2025
Tekla Structural Designer

The following geometry items are required for this method. You can override calculated dimensions using your engineering judgment.

Property Description
Ground level in model (ignore wind below) If for some reason, the level 0.0 feet in the Tekla Structural Designer model does not correspond to the ground level, for example you have used a site datum rather than a building datum, then this field allows you to set the appropriate value so that the reference heights for the wind can be calculated correctly. The default is zero. The allowed maximum is the minimum wall or roof height. Changing the value in this field will cause the Mean Roof Height to be recalculated, unless you have chosen to override that dimension.
Orientation

This is the orientation of the building's principal axes and is similar to the Orientation of Longitudinal Direction relative to axes (Figure 28.4-1) for Low-Rise Buildings. Although there is no need to distinguish between the Longitudinal and Transverse axes for this method, the wind X axis will be aligned to this direction with the Y axis at right angles. The vortex view will be slightly different to the Low-Rise one to reflect that.

Due to the potential complexity of the model, the Wind Wizard will only attempt to determine the correct angle for the axes if the building is also suitable for Low Rise, otherwise zero is used as the default.

Mean roof height, h1

For this method, the actual reference height is only used for the pressure on windward walls. For all other walls, and roofs, a single height is used to determine the pressure for each direction.

By default, the height is calculated as for Low-Rise Buildings except that there is no single value of θ, so the eaves height is only used if all the roof angles are <= 10°. You are able to override the calculated value by checking the box.

Level of highest opening in building2 For this method, qi is evaluated at height h for all cases except for positive internal pressure in partially enclosed buildings, where it should be evaluated at the level of the highest opening. However, the clause allows h to be used even for this case, so the default is for the box to be checked and the level to be automatically updated as the Mean Roof Height changes.
Overall building X' dimension and Overall building Y' dimension3

These dimensions are calculated from the smallest enclosing rectangle (considered over all roof and walls only), relative to the given orientation of the Principal Axes - see figure below. You are able to override each calculated value by checking its box. These values will then be used to derive the L and B dimensions for each wind direction.

For X Axis, L = X Dimension, B = Y Dimension.

For Y Axis, L = Y Dimension, B = X Dimension:

Torsion Cases 2 & 4
Design pressure factor4 This defaults to 75%, but the commentary suggests that this may not cover all cases so you are allowed to change it. A single factor is used for all Torsional loadcases.
Eccentricity5 This defaults to 15% but again, the commentary suggests that this may not cover all cases so you are allowed to change it. A single factor is used for all Torsional loadcases.
Tornado Loads
Note: These parameters are only displayed if tornado loads are being considered for the ASCE-7-22 Rigid Buildings of All Heights method.
Risk Category Tornado loads only need to be considered for risk category III IV.
Effective plan area (building/facility), Ae Defaults to the X' and Y' dimensions specified above.
Clicking Next takes you to the Basic wind data page.

Footnotes

1 ASCE7-10 Clause 26.2
2 ASCE7-10 Clause 27.4.1
3 ASCE7-10 Clause 26.3
4 ASCE7-10 Figure 27.4.8 and Clause 27.4.6
5 ASCE7-10 Figure 27.4.8 and Clause 27.4.6