When undertaking an Autodesign, the Size Constraints property allows you to ensure that the sections proposed by Tekla Structural Designer match any particular size constraints you may have.
For instance:
- Minimum width - you may want to ensure a minimum flange width to satisfy bearing requirements for any supported beams. To achieve this, you would enter a value as the Minimum width, and Tekla Structural Designer would not consider sections with flanges less than the specified minimum width for the design of the beam.
- Maximum depth - you may want to ensure that the maximum beam depth is specified to ensure that it fits within a floor zone. To achieve this, you would enter a value as the Maximum depth and Tekla Structural Designer would not consider sections with depths greater than the specified value for the design of the beam.
- Max span/depth ratio (beams only) - you may want to set a max span/depth
ratio limit above which autodesign will reject sections that are of
insufficient depth.
- The depth is taken as the depth from the section properties - for single and double angles this is the vertical leg length.
- Limit is not applied to any member which has rotation.
Note: Size constraints only work when undertaking
an Autodesign
Applying a size constraint to an element
You can control which sections in a design order list are considered, by following the procedure below.