Virtual joist design is distinct from steel joist design, for information about the latter, see: Steel joist design
Overview
Virtual Joists and Virtual Girders are tools developed by the Steel Joist Institute (SJI) to assist the engineer in preparing building structural models during the design phase. They are intended to bridge the historical gap where engineers lacked specific design properties for joists and joist girders when initially modeling the overall building structure.
Unlike actual joists or joist girders which are custom-designed members, Virtual joists and virtual joist girders are represented by tables of approximate section properties developed by the SJI. These properties are intended for use in structural models to provide a reasonably close approximation of the final joist or joist girder's chord area, effective moment of inertia, and weight.
The key concept to be aware of is that Tekla Structural Designer treats virtual joists and virtual joist girders as though they are custom wide-flanged plated beams when they are being designed. This allows you to make appropriate preliminary member selections, display section properties, and calculate approximate weights early in your design process.
The SJI tables contain a total of 1236 individual virtual joists across 28 series and 3978 individual virtual joist girders across 51 series.
Assumptions and limitations
The following assumptions and limitations currently apply to the design of virtual joists and virtual joist girders in Tekla Structural Designer:
-
Virtual joists and virtual joist girders are considered as simply supported members, except when virtual joist girders are specifically used as part of a Lateral Force Resisting System (LFRS) allowing moment connections. Note however, that while virtual joist girders with moment connections can be analysed, they cannot currently be designed.
-
Virtual joists and virtual joist girders cannot be released axially.
-
Cantilevered joists cannot be defined.
-
Virtual joist girders are able to support other joists and brace members, virtual joists are only able to support brace members.
-
Virtual joist and virtual joist girder inertia and area values are taken directly from the Steel Joist Institute tables.
-
For all joist types, any resulting load, other than those in the major axis, that exceeds the user specified “Ignore Forces for Member Design below” setting in Design Settings is reported as a Warning in the results viewer along with the type and value of force detected.
-
Continuous lateral torsional buckling restraint is automatically applied to virtual joists and virtual joist girders.
-
Camber can not be applied to any joist type in Tekla Structural Designer.
-
Moment connections at virtual joist ends are not allowed.
-
Fire resistance requirements are not designed nor checked in Tekla Structural Designer, the designer must ensure suitable compliance.
-
There is no design for net uplift currently although uplift can exist in a combination provided it is overcome by other gravity loads.
-
In Tekla Structural Designer a dedicated steel grade SJI VJ-50, matching the properties defined by the SJI, is provided for virtual joists and virtual joist girders. It is the user's responsibility to check the suitability of this and any other grade they wish to use. No adjustment is made for higher or lower grades and this is entirely the designer’s call.
Modeling and properties
To create these members click the droplist
under Joist
on the
Model ribbon, then from the Virtual sub-menu select the "Standard" or
"Girder" member type option you require
For both virtual joists and virtual girders a specific material grade called SJI VJ-50 is provided. This grade has properties similar to A992-50 steel, but with an increased density to account for the weight of web members and miscellaneous materials.
Approximate section properties are provided in databases derived by the SJI. The effective moment of inertia for virtual members includes an allowance for the reduced shear rigidity of the open web system. Order files based on increasing strong-axis inertia (Ixx) are used for auto-design selection.
Default section sizes and size constraints (min/max depth) are predefined for virtual members.
Model connectivity
In Tekla Structural Designer, members can only connect to virtual joists at their ends. However virtual joist girders permit members to attach anywhere along their length.
Analytical end fixity
While virtual joists only permit pinned ends, virtual joist girders, when part of a Lateral Force Resisting System (LFRS), may require a Moment (pin Mz) connection defined at one or both ends, (but refer to the section on Assumptions and limitations). They are not permitted to have "Fully Fixed" connections due to a lack of out-of-plane rigidity or strength.
Graphical representation
Virtual joists and virtual joist girders are graphically represented differently from steel joists and joist girders. Instead of displaying wires, the web area is shown as a shaded plane to indicate their virtual nature.

Virtual Joist Loading
Loads on virtual joists are typically derived from one-way load decomposition. Only loads acting in the plane of the webs are considered for design checks. Certain loads, such as minor axis loading, local z (axial) loading, and major axis point moments, are treated as ignored forces in the design check and a warning status is reported.
Design checks
Virtual joists and virtual joist girders are designed as plated doubly symmetric I section beams. Tekla Structural Designer performs auto-design and design checks based on SJI deisgn guides.
-
Auto Design: Uses order files (based on increasing inertia) to select appropriate member sizes. For virtual joist girders, initial sizing considers span/depth ratio limits.
-
Design Checks: Checks include:
-
Flexural Classification
-
Strength: Based on major shear and major flexure.
-
Deflection: By default, span\over limit checks are performed for Live load and Total load. If requested, a span\over limit check can also be performed for Dead load, and absolute limit checks for Dead Load, Live Load, and Total Load.
-
Min. Joist Depth: A warning is issued if the joist depth is less than span/24
-
Max. Joist Depth: A warning is issued if the joist depth exceeds span/12
-
Additional Checks: If (net) uplift is detected for a combination no design is performed for it and a warning message is displayed.Note: If uplift exists in a loadcase but is ‘overcome’ by positive loading in another loadcase then the design is valid and no warning is displayed.
-
Virtual joist member reports
Virtual joist and virtual joist girder design results can be viewed on the screen and incorporated into member design reports. Virtual joists and virtual joist girders are also included in material listing reports.
The same Steel Joist member type is used for configuring the member design report for all steel and virtual joist types. For this member type the report is limited to the following chapters:
| Chapter | Content |
|---|---|
| Picture | ![]() |
| Drawing | ![]() |
| Loading | ![]() |
| Design Summary | ![]() |
| Design Calculations | ![]() |