Skip to main content

Footfall analysis basic workflow - AISC DG11

Modified: 31 Oct 2025 Tekla Structural Designer 2025
2025
Tekla Structural Designer

The guidance in AISC DG11(Ref. 2) is generally based on steel buildings with composite or precast floors. However, the footfall assessment process in Tekla Structural Designer can be performed on models of any material with floors of any construction type. Where the structure is not predominantly a steel building with composite or precast floors, it is the engineer’s responsibility to determine the applicability of AISC DG11, and thus the footfall assessment in Tekla Structural Designer which follows this, to their structure.

To illustrate the basic workflow when working to the AISC DG11 design guide, the composite steel beam structure shown below will be used.


Download and open the tutorial model

  1. Download the tutorial model zip file Footfall - AISC DG11.zip from here.
  2. Extract the following tutorial model from the zip:
    • Footfall - AISC DG11.tsmd
  3. Open the model in Tekla Structural Designer.

Open a footfall analysis view

  1. Open a Structure 3D Scene view.
  2. In the Status bar at the bottom of the main window, click the Footfall Analysis View regime button.

    The Footfall Analysis ribbon becomes available, and the active view switches to a Footfall analysis view.


    Tip:

    In any view you can simply right-click a slab item and select Create Floor Analysis Model from the context menu in order to begin creating a new FAM. It is not essential for you to switch to the Footfall Analysis View regime first.

Confirm the floor analysis model settings

  1. On the Footfall Analysis ribbon, select Settings

    The available settings sets for each design guide are displayed.

  2. In the left hand pane, select AISC DG11 > AISC DG11 settings > Analysis Settings


    It is anticipated that most users will not need to adjust the default analysis settings which are as shown above.

  3. In the left hand pane, select AISC DG11 > AISC DG11 settings > Analysis Model Options


    These options allow you to configure the FAM to your requirements.

    Note that as our example model contains 1-way spanning composite slabs, by accepting the default options shown above these will be modeled as 2-way meshed slabs with automatically calculated orthotropic properties.

  4. In the left hand pane, select AISC DG11 > AISC DG11 settings > Concrete Modification Factors


    Note that by accepting the defaults shown above the static concrete modulus of elasticity will be factored by 1.35 to account for the greater stiffness of concrete in a composite floor under dynamic loading, as recommended in AISC DG11.

    For more information on the different settings, options and factors, see: Footfall assessment settings

  5. In the left hand pane, select Settings Sets Management

    Although It is anticipated that the previously displayed settings will be appropriate in most cases, you can add further sets to investigate different configurations if you require. This would be achieved after selecting the AISC DG11 design guide via the Add or Copy buttons shown below.


  6. We don't need to add a further set so click OK to exit.

Create a floor analysis model

  1. On the Footfall Analysis ribbon, in the Design Guide list, ensure AISC DG11 is selected.


  2. On the Footfall Analysis ribbon, select New

  3. Select the slab item shown below.


    A new Floor Analysis Model (FAM) view opens in Edit mode and the Floor Analysis Model (FAM) properties are displayed in the Properties window.


    When in Edit mode, editing commands are available at the top of the Properties window which enable slab items and other members to be added or removed from the FAM.


Add slabs (and attached members)

Note: DG11 recommends that the FAM be limited in its size and indicates that considering a large floor area might be unconservative. For a slab item of interest the FAM should include only those slabs immediately adjacent. So for a regular building a ‘middle’ slab would create a model of 9 similar slabs including the one of interest. This is entirely at the user’s control in Tekla Structural Designer.

Additional slab items can be added either by clicking them individually, or by box selecting. Note that the Selection Mode in the Properties window, which defaults to ‘Add or Remove’ can also be set to ‘Add Only’ or ‘Remove Only’ to assist this process.

For this example we want the analysis model to only comprise the central area of floor. The quickest way to achieve this is as follows:

  1. In the Properties window, set the Selection Mode to ‘Add Only’

  2. Use the ViewCube to switch to a top view.

  3. Drag a box from left to right around the slab items as shown:


Any slab items totally enclosed by the box are added to the model along with any attached members/walls.

The model should now look as follows:


Add and edit spandrel beams

Spandrel beams can be used to model the restraining effect of cladding on the building perimeter.

  1. Use the ViewCube to switch back to an isometric view.

  2. In the Properties window, select Generate Spandrel Beams


As shown above, all beams around the perimeter of the FAM are initially marked as spandrel beams. Some editing may be required if the default marking is inappropriate.

In this case we will remove the spandrel beam marking from those beams that aren’t actually on the building edge as follows.

  1. In the Properties window, change the Entity type to 'Spandrel Beam'.


  2. Set the Selection Mode to 'Remove Only'.

  3. Use the ViewCube to switch back to a top view.

  4. Drag a box from left to right around the beams along the bottom edge of the FAM as shown:


  5. Drag a similar box around the spandrel beams along the top edge of the FAM.


  6. Use the ViewCube to switch back to an isometric view.


  7. There are still three remaining spandrel beam markings adjacent to the lift core opening. Click on these individually to remove them.


  8. The FAM model is now complete, so press ESC on the keyboard to exit Edit mode.

Confirm the design guide, settings and meshing

Review the following properties located at the top of the Properties window.

  1. Ensure the Design Guide 'AISC DG11' and the Settings set 'AISC DG11 settings' are both selected.

    In a real model you could have created multiple FAM Settings sets, in which case you could then choose which set to apply.

  2. Review the meshing properties.

    The mesh defaults are reasonable and will be left unchanged.

Note: DG11 provides some guidance on meshing. It recommends 1/10 th of the bay size and suggests not to over-refine the mesh as the natural frequency calculation is only accurate to within 5 to 10% anyway. If refinement is felt necessary then that process should stop when change in the natural frequencies is no larger than 0.05 to 1.0 Hz

Create a footfall mass combination

  1. On the Footfall Analysis ribbon, select Footfall Mass Combinations.


    Any existing combinations for static design will be listed in this dialog followed by a Footfall Mass combination which is selected as shown above. Two loadcases have automatically been included in this combination.

  2. Include the Dead and the Live loadcases.


  3. Click the Applied mass tab in the dialog.

    No changes are required here, but note that for Footfall mass combinations, the applied mass defaults to being applied in the Z direction only.


  4. Click OK to save the footfall mass combination.
Note:

In real models engineering judgment will be required when defining the footfall mass combination. The list of available loadcases can potentially be very long and you will also need to consider if the load factors are appropriate. Certain recommendations are given in DG11 section 3.3.

Analyse the model and view the results

On the Footfall Analysis ribbon, there are two analysis choices:

  • Analyse Current - this runs a first-order modal analysis of the currently selected FAM for all active footfall mass combinations.

  • Analyse All - this runs a first-order modal analysis of all FAMs for all active footfall mass combinations.

As only one FAM has been created at this stage, it doesn’t actually matter which of the above two options is selected.

  1. Click Analyse Current

Note:

The FE results you see may vary slightly depending on your installed service pack and may not exactly match the documentation.

View the mode shapes

To view mode shapes graphically for the footfall mass combination:

  1. Select the Footfall Mass combination in the Loading list.


    The mode shapes can then be displayed graphically.

  2. On the Footfall Analysis ribbon, select Mode Shape View.


  3. Cycle through the modes by using the Next and Previous buttons, or by selecting from the Mode list.
  4. To adjust the amplitude of the selected mode shape, drag the Deflections slider in the ribbon as required.
  5. To animate the selected mode shape, right-click in the view, and select Animate from the context menu.
  6. To end the animation, close the Animation dialog.

Configure the footfall checks

Default footfall check parameters for all models can be configured on the Footfall Assessment > AISC DG11 > Footfall Checks page in global settings.

These defaults are automatically copied into the Footfall Checks section of the Properties window for each FAM that is created.


The following parameters are shown in gray because they are fixed and cannot be edited:

  • Cut off frequency (20Hz)

  • Consider all modes (selected)

  • Axis of vibration perception (Z)

The following parameters are editable:

  • walker’s weight (default 168 lbs for US customary units and 76 kg for metric units)

  • damping ratio (default 3%)

  • Fig.2-1 AISC DG11 curve (default Curve A)

For more information about the above parameters, see: Analysis post-processing - AISC DG11

The default values should be adjusted as required to suit the individual FAM, however in this example we shall simply accept all the defaults.

If you were to change any of the above values, the Footfall Assessment results would update automatically - there is no need to re-perform the analysis.

View the footfall check overall results

The footfall checks overall status is displayed in the top left corner of the FAM view.


Note that the status takes into account any potential 'Mass Combination' or 'Response Type' filters applied in the Overall Status & Envelopes section of the Properties window.


By default, all active footfall combinations are considered, and all (i.e. both resonant and transient) responses are considered.

View resonant response results

  1. On the Footfall Analysis ribbon:

    1. Select Sinusoidal Peak Acceleration
    2. Ensure the response type is set to Resonant
    3. Ensure Envelope is unselected.

  2. Select Pass/Fail Status


  3. Hover the cursor over the critical node (indicated by the blue arrow) for more details.


    This node is failing the resonant response because its peak acceleration (0.554%g) exceeds the limiting acceleration (0.500%g).

Note: As previously mentioned, the ‘Overall Status’ in the top corner of the view is controlled from the Properties window, and is therefore considering all response types (resonant and transient, whereas the ‘Current Selection Status’ is controlled from the ribbon and is therefore currently considering the resonant response only.

Resonant response results in detail

Firstly, we can view the data from which the Pass/Fail Status above contours are plotted:

  1. On the Footfall Analysis ribbon, select Tabular Results.

    The Floor Analysis Model Data ribbon is displayed.

  2. From the Footfall Assessment Results group on the ribbon, select Response Parameters

  3. Ensure the response type on the ribbon is set to Resonant


    For each node the following data is displayed:

    • Dominant Frequency - the dominant frequency calculated by the FRF method. (Because we are looking at resonant results, the dominant frequencies are restricted to a maximum of 9Hz.)

    • Sinusoidal Peak Acceleration, (ap) - determined from FRFmax

    • Limiting Sinusoidal Peak Acceleration - determined at the dominant frequency from DG11 Fig.2-1.

    • Acceleration Ratio - ratio of peak, to limiting peak acceleration

    • Status - Pass/Fail status by comparing peak acceleration results with limiting acceleration.

    At each node multiple peak accelerations may have been identified, with the worst case being used to create the graphical Pass/Fail Status contour plot. A filtered view tabulating these for an individual node can be displayed as follows:

  4. From the Footfall Assessment Results group on the ribbon, select Accelerations

  5. Enter the critical node number (for example) in the Node field.


    For this particular node, three separate sinusoidal peak accelerations have been calculated as per Equ. 7.1 of DG11.

  6. To see the data that was used in the above Accelerations calculations for this node, from the Footfall Assessment Results group on the ribbon, select Base Data


    For the selected node the following data is displayed:

    • Dominant Frequency - the dominant frequency calculated by the FRF method.

    • Dynamic Coefficient - determined from DG11 Equ. 7.2

    • Resonant Build-up Factor - determined from DG11 Equ. 7.3.

    • FRFmax - the maximum magnitude of acceleration from the FRF procedure

  7. To see the tabulated response for this node at all frequencies, from the Footfall Assessment Results group, select FRF.


  8. To see the above values plotted, select FRF from the Plots group on the ribbon.


    As shown above, for this node three peaks are identified occurring before 9Hz. These are the FRFmax values and the corresponding dominant frequencies that were displayed earlier in the Base Data table for the resonant response.

View transient response results

  1. Return to the graphical view of the FAM once more.

  2. On the Footfall Analysis ribbon, select Sinusoidal Peak Acceleration

  3. Change the response type from Resonant to Transient (keeping Envelope unselected).


  4. Select Pass/Fail Status


Hover the cursor over the critical node (indicated by the blue arrow) for more details.


This node is passing the transient response because its peak acceleration (0.261%g) is less than the limiting acceleration (0.574%g) .

Transient response results in detail

To view the data from which the Pass/Fail Status above contours are plotted:

  1. On the Footfall Analysis ribbon, select Tabular Results.

    The Floor Analysis Model Data ribbon is displayed.

  2. From the Footfall Assessment Results group on the ribbon, select Response Parameters

  3. Change the response type from Resonant to Transient


    For each node the following data is displayed:

    • Dominant Frequency - the dominant frequency calculated by the FRF method. (Because we are looking at transient results, the dominant frequencies are calculated for the range of 9-20Hz.)

    • Sinusoidal Peak Acceleration - the root mean square sinusoidal peak acceleration, (aESPA), determined from Equ. 7-6 of DG11

    • Limiting Sinusoidal Peak Acceleration - determined at the dominant frequency using DG11 Fig.2-1.

    • Acceleration Ratio - ratio of peak, to limiting peak acceleration

    • Status - Pass/Fail status by comparing peak acceleration results with limiting acceleration.

    While only the worst case Status is used to create the graphical Pass/Fail Status contour plot, multiple peak accelerations are identified at each node.

  4. From the Footfall Assessment Results group on the ribbon, select Accelerations

  5. Enter the critical node number (for example) in the Node field.


  6. For the selected node the following data is displayed:

    • Dominant Frequency - the dominant frequency calculated by the FRF method.

    • Time Step - determined from the step frequency

    • Sinusoidal Peak Acceleration - determined from DG11 Equ. 7.4

  7. Scroll down the list and you will see that multiple dominant frequencies have been identified for this node. Each dominant frequency has been assessed with its own step frequency, (determined using Table 7-1 from DG11). The acceleration is calculated for an individual mode or all modes.

  8. From the Footfall Assessment Results group on the ribbon, select Base Data


    For the selected node the following data is displayed:

    • Dominant Frequency - the dominant frequency calculated by the FRF method.

    • Step Frequency - determined from DG11 Table 7.1

    • Effective Impulse Force - determined from DG11 Equ. 1.6.

    • Sinusoidal Peak Acceleration - determined from DG11 Equ. 7.4 and 7.6

  9. To see the tabulated response for this node at all frequencies, from the Footfall Assessment Results group, select FRF.


    For the selected node the following data is displayed:

    • Frequency

    • Response (in %g/lb) - see section 7.1 of DG11.

  10. To see the above values plotted, select FRF from the Plots group on the ribbon.


    As shown above, for this node multiple peaks are identified after 9Hz. These are occurring at the dominant frequencies displayed in the Base Data table for the transient response.

View enveloped response results

Depending on how it is configured, the envelope option on the ribbon can be used to display results for a selected, or all Mass Combinations; and for respondent, transient, or both response types.

It is configured in the same way as the ‘Overall Status’ via the Overall Status & Envelopes section of the Properties window.


Accepting the default settings shown above, the enveloped results will now be investigated.

  1. Return to the graphical view of the FAM once more.

  2. On the Footfall Analysis ribbon, select Pass/Fail Status

  3. Select Envelope


In the above enveloped view, both resonant and transient responses have been considered (and if there were multiple active footfall combinations they would also have been considered).

The most critical node is failing under a resonant response for the Footfall Mass combination, (the only active combination in this example).

The FAM is failing.

Edit the FAM and add a facade restraint

Facade restraints can be used to vertically restrain specific slab edges.

The existing slab edges are currently unrestrained, we will now apply a facade restraint to one edge to investigate its effect on the results.

  1. From the Footfall Analysis Models group on the ribbon, select Edit

  2. In the Properties window, select Generate Facade Restraint


    As shown above this action has generated facade restraints around the entire FAM perimeter.

    We only want to restrain a single edge, so some further editing is required.

  3. In the Properties window, change the Entity type to 'Facade Restraint'.


  4. Set the Selection Mode to 'Remove Only'.

  5. Drag a box from left to right around the entire FAM.


  6. Set the Selection Mode to ‘Add Only'.

  7. Use the ViewCube to switch to a top view.

  8. Drag a box around the beam spanning the lift core.


  9. Use the ViewCube to switch back to an isometric view.


  10. The editing is now complete, so press ESC on the keyboard to exit Edit mode.

Reanalyse and view the updated results

  1. Click Analyze Current

  2. On the Footfall Analysis ribbon, select Pass/Fail Status

  3. Select Envelope


The FAM is now passing.

Output the calculations

To create a footfall analysis report:
  1. On the ribbon, go to the Report tab.
  2. Click Model Report.
  3. In the Report Contents dialog, click Add and then under Active Style, enter a Name for the report
  4. In the list of chapters and options, select Footfall Analysis and drag it across to the Report Structure area.
  5. Click OK
  6. On the ribbon, in the list on the left side, select the report name you just created.
  7. Click Show Report.

Additional display and review options

Several tabular data views are available, each of which can be exported to Excel.

To display the Floor Analysis Model Data ribbon from where the tabular data views can be accessed:

  1. Make the Floor Analysis Model (FAM) view active once more.

  2. On the Footfall Analysis ribbon, select Tabular Results

The Floor Analysis Model Data ribbon is displayed and an FAM tabular data view opens.


Modal Frequencies

To view modal frequencies, display the Floor Analysis Model Data ribbon and select Modal Frequencies


This table lists the period, frequency, mass participation, and modal mass for each mode.

Mode Shape by Node

To view mode shapes by node:
  1. On the Floor Analysis Model Data ribbon, select Mode Shape by Node
  2. Select the required Mode from the list.

The mode shapes are listed for the selected mode.

FAM solver model

After the analysis has been performed, if you require you can examine the solver model used for the Footfall Analysis model as follows:
  1. Ensure that the required Floor Analysis Model (FAM) view is active.
  2. To change the view type of the FAM view, do one of the following:
    • Right-click the FAM view tab and in the context menu, select Solver view
    • Or, in the Status bar at the bottom of the window, click Solver View.
    The FAM view changes to an FAM solver view.
  3. Right-click anywhere in the solver view.
  4. In the context menu, select Solver models.
  5. In the sub-menu, select Solver Model used for Footfall Analysis.

    Tekla Structural Designer opens the selected solver model. You can then select individual elements in the solver model to display their section and material properties in the Properties window.


Manage FAMs in a Structure 3D view

When a Structure 3D view is active and set to the Footfall Analysis View regime it will display all the floor analysis models that have been created so far.

In this example, only one FAM has been created, so it has been automatically selected.


The following options are available in the ribbon:

  • New - create a new FAM by selecting a slab item.

  • Edit - open the currently selected FAM.

  • Delete - delete an existing FAM by selecting it.

  • Pass/Fail Status - show the pass fail/status of all FAMs

When more than one FAM exists, a color coded legend is displayed and the currently selected FAM is highlighted in purple.


You can change the selected FAM from the Model list in the ribbon.