3D analysis will always develop small shear forces at pinned bases – in two directions - which can over-complicate the base design procedure and results. In many circumstances these forces would traditionally be ignored by engineers or not even evaluated by hand methods.
In Tekla Structural Designer an option is provided to allow these forces to be ignored. This allows the engineer, at their discretion, to define an ignorable % of passive pressure value for pinned bases. (The default for this being 1% of the passive resistance.)
Setting the level of ignorable force is a matter of judgment; it is not defined in any code, and logically it should relate in some way to the size of the foundation.
Activating the option to ignore small shear forces
This option can be activated as follows:
- From the Design tab, select Settings > Concrete > Foundations > Isolated Foundations > General Parameters
- Under Passive Resistance select, Consider passive resistance of soil for sliding check
- Specify the required Ignorable percentage of passive pressure
Impact on the bearing capacity checks
When an ignorable percentage of passive pressure (IPPP) greater than 0% has been specified, the analysis shear reactions Fx,sup and Fy,sup on the applied loads summary are unchanged.
For Moment about X axis:
-
If Mx,sup = 0
-
The Passive Resistance of Soil in Y-Direction (Hy,pas) is calculated
(this can be viewed in sliding resistance check shown below)
-
-
If Fy,sup <= IPPR of Hy,pas
-
In the Bearing Capacity check, because the shear force is less than the ignorable % of passive resistance, the horizontal force in the Y direction is adjusted to zero and the bearing pressure checks continue using the replacement zero value.

-
Else, If Fy,sup > IPPR of Hy,pas
-
The bearing pressure checks continue using the the original Fy,sup value
-
-
For Moment about Y axis:
-
The process is repeated as above reversing X and Y
Impact on the bending capacity, shear capacity, punching capacity, and sliding checks
When an ignorable percentage of passive pressure (IPPP) greater than 0% has been specified, it impacts the remaining checks as follows.
Bearing Capacity Checks:
-
For Moment about X axis:
-
If Fy,sup has been determined as ignorable for bearing (see above) then it is ignored here also.
-
-
For Moment about Y axis:
The process is repeated reversing X and Y
Shear Capacity Checks:
The same adjustments are made as in bending capacity checks above.
Punching Capacity Checks:
The same adjustments are made as in bending capacity checks above.
Sliding Checks:
The same adjustments are made as in bending capacity checks above.