Concrete walls - overview
Concrete walls can be several stories high and can start and finish at any level.
Each wall is automatically split into separate panels only at those construction levels where an element or slab attaches to the wall. At the levels where the wall has been split, wall beam elements are also inserted.
You can define different thicknesses for each wall panel. The panels are then set back on one or both faces, depending on the alignment that you have specified.
Creating a continuous wall in this way, instead of defining a new wall on each floor, does not have any significance for analysis or design purposes. However, it is ultimately important for detailing purposes.
Two types of Fabrication are available In the wall properties: “Cast-in-place”, or “Precast”. For each fabrication type two Concrete types are available: “Normal”, or “Lightweight”. For the selected Concrete type the Grade lists all the available grades in the Materials database under the current regional code.
While the “Meshed Shear Wall” Wall Type is preferred, a “Mid-pier Shear Wall” is also available. The following modeling aspects vary depending on the wall type adopted:
-
Openings are permitted in meshed walls, but ignored in mid-pier walls.
-
Meshed walls can adopt either a rectangular or quadrilateral shape in a single plane that can be vertical or sloping, mid-pier walls must be rectangular in a vertical plane.
-
Releases can be applied to the top, bottom and edges of meshed wall panels, but only to the top and bottom of mid-pier wall panels.
When a meshed wall is used, by default it will adopt the mesh parameters defined in Structure Properties. However, you can override these for an individual wall by checking Override model's in the Meshing section of the wall properties. You are then able to apply a user-defined mesh to the wall.
The points you use to place a concrete wall define the exact size and position of the wall’s analysis model. The alignment and extension properties of the wall have no effect on the analysis model.
Both meshed and mid-pier concrete walls introduce structural strength and stiffness to your model. However, they do not perform the same function as a Wind Wall. This means that wind loads calculated by the Wind Wizard cannot be applied to your structure if the model does not contain wind wall panels. In order to apply wind loads, you must create additional wind wall panels in the same physical locations as the concrete walls.
Only concrete walls can be included in cores, (walls in other materials cannot).
Create rectangular walls in a level view
Create rectangular walls in a frame or structure view
Create quadrilateral walls in a frame or structure view
Concrete wall properties
Select one or more concrete wall and then use the Properties window to view and modify their properties.
| General | |
|---|---|
| Name | The automatically generated name. |
| User Name | Can be used to override the automatically generated name if required. |
| Top Level | Specifies the top level for the wall. |
| Base Level | Specifies the bottom level for the wall. |
| Wall Type |
Meshed Shear Wall Mid-pier Shear Wall Note: Mid-pier shear walls must be rectangular in a vertical
plane. Meshed shear walls can be vertical or
sloping.
|
| Fabrication |
Choice of:
|
| Autodesign |
Cleared - the specified reinforcement will be checked during the design process. Selected - reinforcement will be designed during the design process. |
| Select bars starting from |
This option controls the starting point for auto-design procedures and is therefore only displayed if Automatic design is ‘on’. It applies to both longitudinal bars and links.
|
| Assume extra floors supported | Enter the number of extra floors supported. |
|
Rotation (mid-pier only) |
0° - wall spans horizontally 90° - wall spans vertically |
| AutomaticGenerate Support |
Cleared - a support will only be created if the Generate support property is selected. Selected - a support will only be created if no members/slabs capable of providing support exist under the wall. |
| Generate support |
Cleared - no support is created under the wall. Selected - a support is created under the wall. Note: When a
support is created, a line support is formed under a
meshed wall, a point support under a mid-pier wall, and
a series of point supports under a bearing wall.
Note: When a
support is created, its degrees of freedom are as
specified in the ‘Wall support’ area of the wall
properties.
|
|
KLL (Head Code ACI/AISC) |
Specify the KLL factor in accordance with Table 4-2 in ASCE 7-05/ASCE 7-10. |
| Plane | Indicates the grid along which the wall is placed. |
| All panels | |
|---|---|
| Concrete type | While you can apply both normal and lightweight concrete, wall design using lightweight concrete is currently beyond scope. |
| Grade | The concrete grades that are available here are set from the Materials button on the Home ribbon. |
| Thickness | The thickness of the wall. |
| Alignment |
Alignment of the wall:
|
| Alignment offset | When the alignment is set to User it can be adjusted by specifying an exact offset. |
| End 1 extension |
The amount the wall is extended or trimmed back from end 1. A positive extension extends the wall length beyond its insertion point. A negative extension trims the wall back from the insertion point. Note:
End 1 and End 2 are identified by switching on Walls > Direction in Scene Content. They are assigned when the wall is created as follows. Rectangular wall defined by 2 points: If the two points are at the same elevation - End 1 is at the first point clicked. If the points at different elevations - End 1 is at the lowest of the two points. Non-rectangular wall defined by 4 points: When viewed face on, if the plane of the wall is defined in a clockwise fashion, End 1 is at the right; otherwise it is at the left. |
| End 2 extension |
The amount the wall is extended or trimmed back from end 2. A positive extension extends the wall length beyond its insertion point. A negative extension trims the wall back from the insertion point. |
| Reinforcement Layers |
Number of layers of reinforcement to be used in the wall, (1 or 2). |
| Releases | |
|
Minor Top, Minor Bottom |
Fixed Pinned Continuous (incoming members pinned) (Meshed walls only) For further details, see: Wall releases |
|
Edge 1, Edge 1 (Meshed walls only) |
Fixed Pinned Continuous (incoming members pinned) (Meshed walls only) For further details, see: Wall releases |
| Live Load reduction [ACI/AISC], Imposed Load reduction [Other codes] | |
|
Override calculated value |
This option allows the user to specify their own percentage of load reduction to cater for situations where the automatically calculated value is inappropriate. |
| Analysis & design control | |
| Orthotropic | By default, the wall panels are treated as having isotropic
material properties. Selecting this option allows assigning
orthotropic material properties. For further details, see: Orthotropic walls |
| Calculate properties |
Only available when the Orthotropic option has been selected. Allows setting material properties in two in-plane directions automatically based on the stiffness modification X and Y factors below. For details of how the parameters are calculated, see: Orthotropic wall implementation |
|
X factor - along the length of the wall , Y factor along the height of the wall |
Only available when the Calculate properties option has been selected. Applies stiffness modification factors in the local X and Y directions |
| Ex, Ey, Gxy, Gxz | Gyz, 𝜈x, and 𝜈y |
Allows manually setting material properties, such as Young’s moduli, shear moduli, and the Poisson’s ratio. The fields become editable when the Calculate properties option is cleared (except 𝜈y, which remains read-only). Note: No
distinction is made between Gxz and Gyz out-of-plane shear
moduli.
|
| Apply modification factors |
By default, (unless the Orthotropic option has been selected), the modification factors specified in Analysis settings are applied. When this option is cleared the modification factors are not applied. See also: Use of modification factors |
| Assume cracked |
Assuming concrete sections are cracked has a direct affect on the analysis; smaller modification factors are applied to cracked sections causing an increase in deflection. Indirectly the design can also be affected because the sway/drift sensitivity calculations are also influenced by this assumption. See: Cracked, partially cracked, and uncracked concrete members The Assume cracked option is not available when the Orthotropic option has been selected. |
| Design parameters | |
|
Permanent load ratio option, Relative humidity (RH), Age of loading |
You are required to supply a value for the permanent load ratio parameter. A default of 0.65 has been assumed, but you are advised to consider if this is appropriate and adjust as necessary. Age of loading is the age at which loading is applied. |
| Sway and drift checks | |
| Merge with stack below |
Columns are divided into stacks and walls are divided into panels at floor levels where members or slabs connect to the column/wall. For the purposes of Sway/Drift, Wind Drift and Seismic Drift checks only you can override the default stack/panel divisions by merging a stack/panel with a lower stack/panel. The length of the combined stack/panel is then used in the checks. |
| Sway/Seismic drift checks |
By default all stacks of all walls are taken into account in the calculation to determine the sway sensitivity of the building. The results of this calculation being accessed from the Review toolbar. This parameter provides a facility to exclude particular wall panels from these calculations to avoid spurious results associated with very small panel lengths. You can either clear the checkbox located under ‘All Panels’ to exclude the entire wall, or you can exclude a particular panel by clearing the checkbox located under that panel only. |
|
Wind drift check, Wind drift ratio |
Wind drift is automatically checked against the specified limiting ratio, (which can be set differently for different columns). The results of this calculation are accessed from the Review toolbar. If you don’t want this check to be performed you can either clear the checkbox located under ‘All Panels’ to exclude the entire wall, or you can exclude a particular stack by clearing the checkbox located under that panel only. |
| Confinement reinforcement | |
| Provide support regions |
Selected - confinement reinforcement is designed separately in three regions. Cleared - the same confinement reinforcement is designed for the whole stack. |
| Slenderness | |
|
Major, Minor |
Braced Bracing |
|
Effective length factor direction Major, Effective length factor direction Minor, |
Calculated User input value |
| Stiffness | |
| Use slab for calculation (upper major/ minor, lower major/minor) |
For the unrestrained length calculation:
See: Stiffness |
| Nominal cover | The nominal concrete cover is the distance between the surface of the reinforcement closest to the nearest concrete surface (including links and surface reinforcement where relevant) and the nearest concrete surface. |
| Seismic | |
| In a seismic force resisting system |
If this is the case, select the checkbox, and then specify the SFRS direction and type. Note: Design
of members in seismic force resisting systems is only
supported for the ACI/AISC Head Code in the current
release.
|
|
Shear demand/shear capacity ratio in Dir 1, Shear demand/shear capacity ratio in Dir 2 (ASCE 7 code only) |
When working to the ASCE 7, the engineer can directly define the shear demand / capacity ratio (beta) in each direction. The default value of 1.0 could be over-conservative. The setting is applicable to all years of the ASCE 7 code and has the following default and limits: Default = 1; Min = 0.001; Max = 10. |
| Utilization ratio | |
| Apply (to autodesign) | On
|
| Apply (to check) | On
|
| Ratio limit | The utilization ratio against which the autodesign or check is performed (when applied above). |
| Wall support | |
|---|---|
| Angles (Fx/Fy/Fz, Mx/My/Mz) |
Used to specify the translational and rotational degrees of freedom in which the support acts:
|
| Translational stiffnesses (x/y/z) |
Used to specify the translational stiffness applied in a direction that is not fixed:
|
| Rotational stiffnesses (x/y/z) |
Used to specify the rotational stiffness applied in a direction that is not fixed:
|
| Reinforcement | |
|---|---|
| Include end zones |
Cleared - the wall is designed without end zones of reinforcement Selected - the wall is designed with end zones of reinforcement
|
| Wall zone | |
| Form, type class | Specifies the wall zone reinforcement properties |
| End zone | |
| Form, type class | Specifies the end zone reinforcement properties (if end zones have been requested). |
| Panel 1, 2, 3 etc. | |
|---|---|
|
In a multi-panel wall properties can be entered for a specific panel, over-riding those defined at the All panels level. |
|
| Count the floor as being supported | |
|---|---|
|
Top level (Intermediate levels) Base level (Head Code Eurocode, BS or IS) |
If selected, the floor will be treated as supported when calculating the live/imposed load reductions. |
| Restrained | |
|---|---|
|
|
Used to indicate if the wall is restrained or not at intermediate floor levels. Engineering judgement may be required, for example:
Note:
Only intermediate levels with a connecting member are listed. Restraint is always assumed at the bottom and top of the wall, so the bottom and top levels are not listed. |
| Meshing (meshed walls only) | |
|---|---|
| Override Model’s | Select this checkbox to override the default wall mesh size that is specified in the Structure properties. |
| Wall Mesh Horizontal Size | Used to override the default wall horizontal mesh size (1.000m). |
| Wall Mesh Vertical Size | Used to override the default wall vertical mesh size (1.000m). |
| Wall Mesh Type |
Available mesh types:
|
| UDA | |
|---|---|
|
Name Finish Class Phase Note File |
A customizable list of the attributes that can be applied to individual members and panels. |
droplist.