Skip to main content

Non-seismic design - general (ACI 318-19 update)

Modified: 6 Nov 2026 Tekla Structural Designer 2025
2025
Tekla Structural Designer

Summary

When working to the 2019 version of the code, the Concrete design to ACI 318 checks are amended as follows:

  • Clause 20.2.2.4 - Revision to reinforcement strength - Limited allowance of 100 ksi reinforcement so added grade of 100 ksi for reinforcement.

  • Reinforcement yield strength (fy) shall be limited to a maximum of 100 ksi in the calculation of all members for non-seismic design.

  • As per Table 21.2.2 - Revision of strain limit from 0.004 to εty + 0.003 for tension controlled section. Updated changes wherever required in the calculation of flexure checks.

  • Clause 19.2.1.1 - Added minimum compressive strength (f'c) check.