Skip to main content

Additional reinforcement for torsion (concrete beam: EC2)

Modified: 9 Nov 2026 Tekla Structural Designer 2025
2025
Tekla Structural Designer

The design value of the shear resistance of a concrete section with no shear reinforcement, VRd,c, is given by:1

VRd,c = vmin · bw · d

For design in accordance with:
  • EC2 Recommendations, UK NA, Irish NA, Malaysian NA, Singapore NA, Finnish NA, Swedish NA:

    CRd,c = 0.18 / γC

    γC = 1.5

    vmin = 0.035 · k1.5 · fck0.5

    where k = min(1 + √(200 / d), 2.0)

  • Norwegian NA:

    CRd,c = 0.15 / γC

    γC = 1.5

    vmin = 0.035 · k(2/3) · min(fck, 65 N/mm2)0.5

    where k = min(1 + √(200 / d), 2.0)

IF (TEd,max / TRd,c) + (VEd,max / VRd,c) ≤ 1.0

THEN no additional longitudinal reinforcement for torsion is required.

IF (TEd,max / TRd,c) + (VEd,max / VRd,c) > 1.0

THEN additional longitudinal reinforcement for torsion, AslT,reqd, is required in some or all regions.

The additional longitudinal reinforcement is given by:

AslT,reqd = (TEd · uk · cot θ) / (2 · Ak · fyd)

where uk = 2 · ((h − tef) + (bw − tef))

This reinforcement is in addition to that required for bending and tension arising from vertical shear and it is distributed in each of the four faces of the beam in proportion to the length of the face of the cross-section.

The area of the additional link reinforcement that is required to resist torsion is given by:

Aswt / s = TEd / (2 · Ak · 0.9 · fywd · cot θ) per leg

Footnotes

1 The design value of the shear resistance is calculated ignoring the longitudinal reinforcement as it is not known if this reinforcement is adequately anchored beyond the point under consideration. This is a conservative approach.