Axial Tension

Checks are performed according to equation 6.5

Implementation of the below clauses is as follows:

  • Clause 6.2.3 (3) - is not considered

    Clause 6.2.3 (4) - is not considered

  • Clause 6.2.3 (5) - is not considered

  • Eqn 6.7 is not considered for steel non-composite beams.

Axial Compression

Checks are performed according to equation 6.9.