Skip to main content

Checks for limiting parameters (pile cap:EC2)

Modified: 9 Nov 2026 Tekla Structural Designer 2025
2025
Tekla Structural Designer

Check for distance of pile cap overhang

Check pile edge distance e for pile i in a pile group for both directions:

The check passes if:

min ei > emin,user

Check for minimum pile spacing

Check center-to-center spacing s between piles i and j in a pile group:

The check passes if:

sij > smin,user

where smin,user = user input

Check for maximum pile spacing

Check center-to-center maximum spacing s between piles i and j in a pile group:

The check passes if:

sij < smax,user

where smax,user = user input

Other checks

The remaining checks are identical to those for pad bases, see: Design parameters for longitudinal bars (concrete beam: EC2)