Check for sliding (pad and strip base: ACI 318)

Modified: 9 Nov 2026 Tekla Structural Designer 2025
2025
Tekla Structural Designer

The check for sliding is carried out for pad foundations only.

If there is no horizontal force acting on foundation, check for sliding is not required.

Resultant force on foundation:

Hd = √[(Fx,sup)² + (Fy,sup)²]

Resultant force angle αHd = arctan(Fy,sup / Fx,sup)

where

  • Fx,sup = horizontal force acting on support in X-direction (from analysis)
  • Fy,sup = horizontal force acting on support in Y-direction (from analysis)

Resistance to sliding due to base friction:

Hfriction = (−P + Fswt) · tan δ

where δ = design base friction (user input)

Passive pressure coefficient:

Kp = (1 + sin ϕ') / (1 − sin ϕ')

where ϕ' = design shear strength of soil (user input)

Passive resistance of soil in X-direction:

Hxpas = 0.5 · Kp · (h² + 2 · h · hsoil) · Lx · ρsoil

Passive resistance of soil in Y-direction:

Hypas = 0.5 · Kp · (h² + 2 · h · hsoil) · Ly · ρsoil

Resultant passive resistance:

Hres,pas = |Hxpas · cos αHd| + |Hypas · sin αHd|

Total resistance to sliding:

RHd = (Hfriction + Hres,pas) / 1.5

If RHd ≥ Hd:

the check for stability against sliding passes.