For some of the shear design parameters, additional user defined limits can be applied - where this is the case minimum and maximum values are specified in Design Settings > Concrete > Cast-in-place > Wall > Reinforcement Layout. These are considered in addition to the EC2 or NA recommendations.
Minimum Shear Link Diameter
φw,min = max[6 mm, 0.25 · largest longitudinal bar diameter]
Maximum Span Region Shear Link Spacing
-
UK NA, Irish NA, Malaysian NA, Singapore NA:1
φw,max = min[20 · smallest longitudinal bar diameter, lesser column dimension, 400 mm]
Note:For UK NA when concrete class > C50/60 there are separate calculations in clause 9.5.3(3). These are not implemented but a warning is displayed in this situation.
-
EC2 Recommendations, Swedish NA:
φw,max = min[20 · smallest longitudinal bar diameter, lesser column dimension, 400 mm]
-
Finnish NA, Norwegian NA:
φw,max = min[15 · smallest longitudinal bar diameter, lesser column dimension, 400 mm]
Note that in the Norwegian NA this limit is reduced by a factor of 0.6 for strength classes equal or above C55/67.
Support Region Shear Link Spacing
For support regions, the maximum link spacing is reduced by 40%. 2
Long Term Compressive Strength Factor for Shear
-
EC2 Recommendations, UK NA, Irish NA, Malaysian NA, Singapore NA, Swedish NA:3
αccw = 1.0
-
Finnish NA, Norwegian NA:
αccw = 0.85
Design Concrete Compressive Strength for Shear
fcwd
-
UK NA, Irish NA, Malaysian NA, Singapore NA:
-
fcwd = αccw · min(fck, 50 N/mm2) / γC
-
-
EC2 Recommendations, Finnish NA, Norwegian NA, Swedish NA:
fcwd = αccw · fck / γC
Factor CRd,c4
-
EC2 Recommendations, UK NA, Irish NA, Malaysian NA, Singapore NA, Finnish NA, Swedish NA:
CRd,c = 0.18 / γC
-
Norwegian NA:
CRd,c = 0.15 / γC
Factor k15
-
EC2 Recommendations, UK NA, Irish NA, Malaysian NA, Singapore NA, Finnish NA, Swedish NA:
k1 = 0.15
-
Norwegian NA:
If σcp ≥ 0, then k1 = 0.15, else 0.30
Cracked Concrete Reduction Factor, v
-
EC2 Recommendations, UK NA, Irish NA, Malaysian NA, Singapore NA, Finnish NA, Norwegian NA, and Swedish NA:6
v = 0.6 · (1 − (fck / 250))
Cracked Concrete Reduction Factor, v1
-
UK NA: 7
-
v1 = v · (1 − (0.5 · cos α))
α is the inclination of links.
Note that links in columns are always assumed to be at 90° to column direction.
Therefore v1 = v
-
-
EC2 Recommendations, Irish NA, Malaysian NA, Singapore NA, Finnish NA, Norwegian NA, Swedish NA:
v1 = v
Minimum Shear Reinforcement Ratio
-
EC2 Recommendations, UK NA, Irish NA, Malaysian NA, Singapore NA, Finnish NA, Swedish NA:8
ρw,min = 0.08 · √(fck) / fyk
-
Norwegian NA:
ρw,min = 0.1 · √(fck) / fyk
Maximum Angle of Compression Strut
-
EC2 Recommendations, UK NA, Irish NA, Malaysian NA, Singapore NA, Finnish NA, Norwegian NA, and Swedish NA:9
cot θmax = 1
θmax = 45°
Minimum Angle of Compression Strut
-
EC2 Recommendations, UK NA, Irish NA, Malaysian NA, Singapore NA:10
cot θmin = 2.5
θmin = 21.8°
-
Norwegian NA:
If σt = NEd / Ac < fctk,0.05
cot θmin = 2.5
θmin = 21.8°
else
cot θmin = 1.25
θmin = 38.7°
Angle of Compression Strut
-
UK NA: 11
If NEd ≥ 0, i.e. compression:
θ = 0.5 · arcsin(2 · vEd / (0.9 · αcw · v1 · fcwd))
else:
cot θ = 1.25
θ = 38.7°
-
EC2 Recommendations, Finnish NA, Norwegian NA, Swedish NA:
θ = 0.5 · arcsin(2 · vEd / (0.9 · αcw · v1 · fcwd))
-
Irish NA, Malaysian NA, and Singapore NA:
If NEd ≥ 0, i.e. compression:
θ = 0.5 · arcsin(2 · vEd / (0.9 · αcw · v1 · fcwd))
else:
cot θ = 1.00
θ = 45°
Stress State Factor
-
EC2 Recommendations, UK NA, Irish NA, Malaysian NA, Singapore NA, Finnish NA, Norwegian NA, and Swedish NA:
If σcp ≤ 0
αcw = 1.0
else if 0 < σcp ≤ 0.25 · fcd
αcw = 1.0 + (σcp / fcd)
else if 0.25 · fcd < σcp ≤ 0.5 · fcd
αcw = 1.25
else if 0.5 · fcd < σcp ≤ fcd
αcw = 2.5 · (1.0 − (σcp / fcd))
Minimum Shear Strength
-
EC2 Recommendations, UK NA, Irish NA, Malaysian NA, Singapore NA, Finnish NA, Swedish NA:12
vmin = 0.035 · k1.5 · fck0.5
-
Norwegian NA:
vmin = 0.035 · k2/3 · min(fck, 0.65)0.5