Skip to main content

Design parameters for shear (Concrete wall: EC2)

Modified: 10 Nov 2022 Tekla Structural Designer 2025
2025
Tekla Structural Designer

For some of the shear design parameters, additional user defined limits can be applied - where this is the case minimum and maximum values are specified in Design Settings > Concrete > Cast-in-place > Wall > Reinforcement Layout. These are considered in addition to the EC2 or NA recommendations.

Minimum Shear Link Diameter

φw,min = max[6 mm, 0.25 · largest longitudinal bar diameter]

Maximum Span Region Shear Link Spacing

For design to:
  • UK NA, Irish NA, Malaysian NA, Singapore NA:1

    φw,max = min[20 · smallest longitudinal bar diameter, lesser column dimension, 400 mm]

    Note:

    For UK NA when concrete class > C50/60 there are separate calculations in clause 9.5.3(3). These are not implemented but a warning is displayed in this situation.

  • EC2 Recommendations, Swedish NA:

    φw,max = min[20 · smallest longitudinal bar diameter, lesser column dimension, 400 mm]

  • Finnish NA, Norwegian NA:

    φw,max = min[15 · smallest longitudinal bar diameter, lesser column dimension, 400 mm]

    Note that in the Norwegian NA this limit is reduced by a factor of 0.6 for strength classes equal or above C55/67.

Support Region Shear Link Spacing

For support regions, the maximum link spacing is reduced by 40%. 2

Long Term Compressive Strength Factor for Shear

For design to:
  • EC2 Recommendations, UK NA, Irish NA, Malaysian NA, Singapore NA, Swedish NA:3

    αccw = 1.0

  • Finnish NA, Norwegian NA:

    αccw = 0.85

Design Concrete Compressive Strength for Shear

fcwd

For design to:
  • UK NA, Irish NA, Malaysian NA, Singapore NA:
    • fcwd = αccw · min(fck, 50 N/mm2) / γC

  • EC2 Recommendations, Finnish NA, Norwegian NA, Swedish NA:

    fcwd = αccw · fck / γC

Factor CRd,c4

For design to:
  • EC2 Recommendations, UK NA, Irish NA, Malaysian NA, Singapore NA, Finnish NA, Swedish NA:

    CRd,c = 0.18 / γC

  • Norwegian NA:

    CRd,c = 0.15 / γC

Factor k15

For design to:
  • EC2 Recommendations, UK NA, Irish NA, Malaysian NA, Singapore NA, Finnish NA, Swedish NA:

    k1 = 0.15

  • Norwegian NA:

    If σcp ≥ 0, then k1 = 0.15, else 0.30

Cracked Concrete Reduction Factor, v

For design to:
  • EC2 Recommendations, UK NA, Irish NA, Malaysian NA, Singapore NA, Finnish NA, Norwegian NA, and Swedish NA:6

    v = 0.6 · (1 − (fck / 250))

Cracked Concrete Reduction Factor, v1

For design to:
  • UK NA: 7

    • v1 = v · (1 − (0.5 · cos α))

      α is the inclination of links.

      Note that links in columns are always assumed to be at 90° to column direction.

      Therefore v1 = v

  • EC2 Recommendations, Irish NA, Malaysian NA, Singapore NA, Finnish NA, Norwegian NA, Swedish NA:

    v1 = v

Minimum Shear Reinforcement Ratio

For design to:
  • EC2 Recommendations, UK NA, Irish NA, Malaysian NA, Singapore NA, Finnish NA, Swedish NA:8

    ρw,min = 0.08 · √(fck) / fyk

  • Norwegian NA:

    ρw,min = 0.1 · √(fck) / fyk

Maximum Angle of Compression Strut

For design to:
  • EC2 Recommendations, UK NA, Irish NA, Malaysian NA, Singapore NA, Finnish NA, Norwegian NA, and Swedish NA:9

    cot θmax = 1

    θmax = 45°

Minimum Angle of Compression Strut

For design to:
  • EC2 Recommendations, UK NA, Irish NA, Malaysian NA, Singapore NA:10

    cot θmin = 2.5

    θmin = 21.8°

  • Norwegian NA:

    If σt = NEd / Ac < fctk,0.05

    cot θmin = 2.5

    θmin = 21.8°

    else

    cot θmin = 1.25

    θmin = 38.7°

Angle of Compression Strut

For design to:
  • UK NA: 11

    If NEd ≥ 0, i.e. compression:

    θ = 0.5 · arcsin(2 · vEd / (0.9 · αcw · v1 · fcwd))

    else:

    cot θ = 1.25

    θ = 38.7°

  • EC2 Recommendations, Finnish NA, Norwegian NA, Swedish NA:

    θ = 0.5 · arcsin(2 · vEd / (0.9 · αcw · v1 · fcwd))

  • Irish NA, Malaysian NA, and Singapore NA:

    If NEd ≥ 0, i.e. compression:

    θ = 0.5 · arcsin(2 · vEd / (0.9 · αcw · v1 · fcwd))

    else:

    cot θ = 1.00

    θ = 45°

Stress State Factor

For design to:
  • EC2 Recommendations, UK NA, Irish NA, Malaysian NA, Singapore NA, Finnish NA, Norwegian NA, and Swedish NA:

    If σcp ≤ 0

    αcw = 1.0

    else if 0 < σcp ≤ 0.25 · fcd

    αcw = 1.0 + (σcp / fcd)

    else if 0.25 · fcd < σcp ≤ 0.5 · fcd

    αcw = 1.25

    else if 0.5 · fcd < σcp ≤ fcd

    αcw = 2.5 · (1.0 − (σcp / fcd))

Minimum Shear Strength

For design to:
  • EC2 Recommendations, UK NA, Irish NA, Malaysian NA, Singapore NA, Finnish NA, Swedish NA:12

    vmin = 0.035 · k1.5 · fck0.5

  • Norwegian NA:

    vmin = 0.035 · k2/3 · min(fck, 0.65)0.5

Footnotes

1 EN 1992-1-1:2004 Section 9.5.3(3)
2 EN 1992-1-1:2004 Section 9.5.3(4)
3 EN 1992-1-1:2004 Section 3.1.6(1)
4 EN 1992-1-1:2004 Section 6.2.2(1)
5 EN 1992-1-1:2004 Section 6.2.2(1)
6 EN 1992-1-1:2004 Section 6.2.2(6)
7 EN 1992-1-1:2004 Section 6.2.3(3)
8 EN 1992-1-1:2004 Section 9.2.2(5)
9 EN 1992-1-1:2004 Section 6.2.3(2)
10 EN 1992-1-1:2004 Section 6.2.3(2)
11 EN 1992-1-1:2004 Section 6.2.3(2)
12 EN 1992-1-1:2004 Section 6.2.2(1)