Design for in plane shear (concrete wall: ACI 318)

Modified: 6 Nov 2026 Tekla Structural Designer 2025
2025
Tekla Structural Designer

In the plane of the wall the factored shear must be equal to or less than the design shear strength of the wall:

Vu ≤ ϕ · Vn

The design shear strength of the wall is equal to the design shear strength of the concrete plus that of the shear reinforcing:

Vu ≤ ϕ · Vc + ϕ · Vs

The shear strength, Vn, may not be taken greater than 10 · √f'c · h · d:

Vn ≤ 10 · √f'c · h · d (US units)

Vn ≤ 0.83 · √f'c · h · d (metric units)

where

  • h = wall thickness
  • d = 0.8 · lw
  • lw = length of the wall

Out of plane the shear design calculations are the same whether the design element is a column or a wall - see: Design parameters for shear (column and wall:ACI 318)