Note: For some of the longitudinal reinforcement design parameters, additional user defined limits can be applied - where this is the case minimum and maximum values can be specified from the Design tab on the ribbon by clicking Settings > Concrete > Wall > Reinforcement Layout.

Minimum Longitudinal Bar Spacing

For design to ACI:

minimum clear distance ≥ max(1.5 · longitudinal db, 1.5 in, 1.33 · hagg) (US units)

minimum clear distance ≥ max(1.5 · longitudinal db, 40 mm, 1.33 · hagg) (metric units)

where

  • db = bar diameter
  • hagg = aggregate size

Maximum Longitudinal Bar Spacing

You are given control over this value by specifying an upper limit via the Design Settings as mentioned in the Note above.

Minimum Longitudinal Total Steel Area

For design to ACI:

1% · column area

Maximum Longitudinal Total Steel Area

For design to ACI:

8% · column area