Skip to main content

Design parameters for vertical bars (concrete wall: ACI 318)

Modified: 9 Nov 2026 Tekla Structural Designer 2025
2025
Tekla Structural Designer
Note: For some of the longitudinal reinforcement design parameters, additional user defined limits can be applied - where this is the case minimum and maximum values can be specified from the Design tab on the ribbon by clicking Settings > Concrete > Wall > Reinforcement Layout.

Minimum and Maximum Vertical Bar Diameter

There are no code provisions, but user defined limits can be applied to the minimum and maximum bar diameters - specified in the Design Settings > Wall > Reinforcement Layout.

There are no code provisions, but user defined limits can be applied to the minimum and maximum bar diameters - these are specified via the Design Settings as mentioned in the Note above.

Minimum and Maximum Vertical Loose Bar Spacing

Limiting minimum horizontal spacing of the vertical bars, sv,lim,min, is controlled by the diameters of the 2 adjacent bars and aggregate size:1

sv,lim,min = 0.5 · (dbv,i + dbv,(i+1)) + cgap

cgap = max(1.5 · dbv,i, 1.5 · dbv,(i+1), 1.33 · hagg, 1.5 in) (US units)

cgap = max(1.5 · dbv,i, 1.5 · dbv,(i+1), 1.33 · hagg, 38 mm) (metric units)

where

  • cgap = minimum clear distance between bars
  • dbv,i and dbv,(i+1) = the diameters of the two adjacent vertical bars
  • hagg = aggregate size

Limiting maximum horizontal spacing of the vertical bars, sv,lim,max, is controlled by the wall thickness:

sv,lim,max = min(3 · hw, 18 in) (US units)

sv,lim,max = min(3 · hw, 450 mm) (metric units)

You are given control over these values by specifying minimum and maximum spacing limits - these are specified via the Design Settings as mentioned in the Note above.

Minimum and Maximum Reinforcement Area

The code provisions which control the vertical reinforcement area are:

  • Limiting minimum ratio of vertical reinforcement area to gross concrete area, rv,lim,min
  • Limiting maximum ratio of vertical reinforcement area to gross concrete area, rv,lim,max

The controlling values are:

If dbv ≤ No. 5 (No. 16) with fy ≥ 60000 psi (420 MPa) OR WWR ≤ W31 or D31:

then ρv,lim,min = 0.0012, else 0.0015 for all other deformed bars

Total minimum area of vertical reinforcement, As,min = ρv,lim,min · Acg

Total maximum area of vertical reinforcement, As,max = ρv,lim,max · Acg = 0.08 · Acg

where Acg = gross area of the concrete wall

Where 2 layers are specified, this should be distributed equally to each face.

You are given further control over the minimum and maximum reinforcement ratio values via user limits - these are specified via the Design Settings as mentioned in the Note above and will be used if they are more onerous than the code limits.

Footnotes

1 Clause 7.6.3
Submit

Table of Contents