Skip to main content

Flexural reinforcement (columns seismic: ACI 318)

Modified: 21 Mar 2025 Tekla Structural Designer 2025
2025
Tekla Structural Designer
Development Length at the Foundation

Columns that are part of Special Moment Frames shall have their longitudinal reinforcement extended into supporting footings, foundation mats or pile caps for a length not less than the full development length in tension.

Lap Splices

Specific seismic requirements apply only to lap splices in compressive members that are part of Special Moment Frames.

For columns that are part of Special Moment Frames:

  • lap splices are only allowed at the center half of the column
  • lap splices regions should be properly confined - hoop spacing should not exceed the maximum allowed hoop spacing
Note: Both of these requirements are beyond scope in the current release of Tekla Structural Designer.