General requirements (beams seismic: ACI 318)

Modified: 6 Nov 2026 Tekla Structural Designer 2025
2025
Tekla Structural Designer

Maximum allowed factored axial force

Flexural elements with high axial loading values under any load combination are handled in the seismic design and detailing as compressive members.

If SFRS Type = Ordinary Moment Frame, then no axial compression limit applies.

If SFRS Type = Intermediate Moment Frame or SFRS Type = Special Moment Frame:

Pmax = Ag · f'c / 10

where

  • Pmax = maximum allowed compression value on the member
  • Ag = gross area of the concrete section
  • f'c = specified compressive strength of concrete

The check passes if:

Pu ≤ Pmax

where

  • Pu = maximum factored compressive axial force anywhere in the span considering all load combinations

Maximum allowed effective depth

The maximum allowed effective depth of a beam part of a Special Moment Frame is proportional to its clear span length to limit the overloading of the adjacent joints and columns.

If SFRS Type = Special Moment Frame:

d ≤ dmax

dmax = 0.25 · ln

where

  • d = distance between extreme compression fiber and longitudinal tension reinforcement centroid
  • dmax = maximum allowed distance between extreme compression fiber and longitudinal tension reinforcement centroid
  • ln = length of clear span measured face-to-face of supports

Minimum allowed width

Beams part of Special Moment Frames in buildings subjected to earthquake effects have a minimum width limit for their web.

If SFRS Type = Special Moment Frame:

bw ≥ bw,min

bw,min = max(0.3 · h, 250 mm) (metric units)

bw,min = max(0.3 · h, 10 in) (US units)

where

  • bw = beam web width
  • bw,min = minimum allowed beam web width
  • h = overall depth of concrete section

Maximum allowed width

Despite not being advisable, beams in Special Moment Frames are allowed to be wider than the supporting columns up to a fixed limit.

Note: The maximum lateral extension of a beam on each side of the joining column is beyond scope in the current release of Tekla Structural Designer.