Maximum allowed factored axial force
Flexural elements with high axial loading values under any load combination are handled in the seismic design and detailing as compressive members.
If SFRS Type = Ordinary Moment Frame, then no axial compression limit applies.
If SFRS Type = Intermediate Moment Frame or SFRS Type = Special Moment Frame:
Pmax = Ag · f'c / 10
where
- Pmax = maximum allowed compression value on the member
- Ag = gross area of the concrete section
- f'c = specified compressive strength of concrete
The check passes if:
Pu ≤ Pmax
where
- Pu = maximum factored compressive axial force anywhere in the span considering all load combinations
Maximum allowed effective depth
The maximum allowed effective depth of a beam part of a Special Moment Frame is proportional to its clear span length to limit the overloading of the adjacent joints and columns.
If SFRS Type = Special Moment Frame:
d ≤ dmax
dmax = 0.25 · ln
where
- d = distance between extreme compression fiber and longitudinal tension reinforcement centroid
- dmax = maximum allowed distance between extreme compression fiber and longitudinal tension reinforcement centroid
- ln = length of clear span measured face-to-face of supports
Minimum allowed width
Beams part of Special Moment Frames in buildings subjected to earthquake effects have a minimum width limit for their web.
If SFRS Type = Special Moment Frame:
bw ≥ bw,min
bw,min = max(0.3 · h, 250 mm) (metric units)
bw,min = max(0.3 · h, 10 in) (US units)
where
- bw = beam web width
- bw,min = minimum allowed beam web width
- h = overall depth of concrete section
Maximum allowed width