Limitations and assumptions (columns seismic: ACI 318)

Modified: 9 Nov 2022 Tekla Structural Designer 2025
2025
Tekla Structural Designer

The following limitations and assumptions apply.

  • Seismic design is only performed for columns marked as part of a Seismic Force Resisting System.
  • Requirements for columns particularly in the case of members not part of any SFRS when in Seismic Design Categories D through F are not considered in the current release.
  • The design and detailing requirements of members part of Special Moment Frames is beyond scope (some checks are implemented but only due to their existence in lower toughness systems).
    Note: A full list of the code checks that have and have not been implemented is provided in the table below.
  • No height limitations apply to Seismic Force Resisting Systems in the form of Moment Resisting Frames according to ASCE 7-10, Table 12.2-1.
  • The use of spiral reinforcement as well as all seismic design checks and related assumptions are not considered due to the fact that this type of reinforcement is not currently available in Tekla Structural Designer.
  • The Seismic Force Resisting System set by the user in each direction through the Seismic Wizard for analysis purposes is not checked for applicability against the allowed types of the resultant Seismic Design Category. This is a user responsibility.
  • Seismic design checks are mostly based on capacity design obtained from the main reinforcement provided. This can lead to an over-design of structural members if the designer is not careful enough to minimize excess capacity, especially in columns considering the weak beam - strong column philosophy.

ACI 318 Seismic Code Checks for columns that have been implemented in Tekla Structural Designer

Code Ref. Requirement SFRS SDC A SDC B SDC C SDC D,E,F
21.1.4.2 Minimum required compressive strength of concrete SMF - - -
21.1.4.3 Maximum allowed compressive strength of light-weight concrete SMF - - -
21.1.5.2 Maximum allowed steel characteristic yield strength of longitudinal reinforcement SMF - - -
21.1.5.4 Maximum yield strength of transverse reinforcement in confinement regions of columns SMF - - -
21.1.5.5 Maximum allowed longitudinal reinforcement yield strength used in the calculation of transverse reinforcement SMF - - -
21.1.5.5 Maximum allowed characteristic yield strength of shear reinforcement SMF - - -
21.2.3 Design shear force OMF - - -
21.3.2 Minimum factored axial force IMF - - -
21.3.3.2 Design shear force IMF - - -
21.3.5.2 Minimum Support Region size (confinement reinforcement applies) IMF - - -
21.3.5.2 Maximum allowed center hoop spacing in confinement regions IMF - - -
21.3.5.3 First hoop placing distance from face of joint in support regions IMF - - -
21.3.5.3 First hoop placing distance from face of joint in support regions SMF - - -
21.3.5.5 Minimum depth of column transverse reinforcement into the joint IMF - - -
21.3.5.5 Minimum area of column rectangular transverse reinforcement IMF - - -
21.3.5.5 Minimum depth of column transverse reinforcement into the joint SMF - - -
21.3.5.5 Minimum volumetric ratio / area of column spiral or circular transverse reinforcement IMF - - -
21.3.5.6 Length of confinement region when inside footings, mats or pile caps IMF - - -
21.3.5.6 Length of confinement region for columns supporting/above discontinuous stiff members (walls) IMF - - -
21.6.1 Minimum factored axial force SMF - - -
21.6.1.1 Minimum overall dimension SMF - - -
21.6.1.2 Minimum shortest dimension to perpendicular dimension ratio SMF - - -
21.6.2.2/21.6.2.3 Minimum flexural strength SMF - - -
21.6.3.1 Minimum allowed area of reinforcement SMF - - -
21.6.3.1 Maximum allowed area of reinforcement SMF - - -
21.6.3.2 Minimum allowed number of bars in columns with circular hoops SMF - - -
21.6.3.3 Lap splice allowed locations SMF - - -
21.6.3.3 Mechanical Splices within twice the member depth from column/beam face or yielding regions SMF - - -
21.6.3.3 Mechanical Splices outside twice the member depth from column/beam face or yielding regions SMF - - -
21.6.3.3 Welded Splices within twice the member depth from column/beam face or yielding regions SMF - - -
21.6.3.3 Welding of stirrups or other elements to longitudinal reinf. required by design SMF - - -
21.6.3.3 Minimum lap splice length SMF - - -
21.6.4.1 Minimum Support Region size (confinement reinforcement applies) SMF - - -
21.6.4.1 Minimum length of confinement region at other flexural yielding sections SMF - - -
21.6.4.2 Type of confinement reinforcement (hook/extension) SMF - - -
21.6.4.2 Maximum allowed cross section center link leg spacing in confinement regions SMF - - -
21.6.4.3 Maximum allowed center hoop spacing in confinement regions SMF - - -
21.6.4.3 Maximum hoop spacing at lap Splices SMF - - -
21.6.4.4a) Minimum volumetric ratio / area of spiral or circular confinement reinforcement SMF - - -
21.6.4.4b) Minimum area of rectangular confinement reinforcement SMF - - -
21.6.4.5 Maximum center link/stirrup spacing in non special transverse reinf. regions SMF - - -
21.6.4.6 Length of confinement region when inside footings, mats or pile caps SMF - - -
21.6.4.6 Length of confinement region for columns supporting/above discontinuous stiff members (walls) SMF - - -
21.6.4.7 Spacing of transverse reinforcement for non-structural extensions SMF - - -
21.6.5.1 Design shear force SMF - - -
21.6.5.2 Unreinforced Shear resistance at confinement regions SMF - - -
21.7.3.1 Minimum volumetric ratio / area of column spiral or circular transverse reinforcement SMF - - -
21.7.3.1 Minimum area of column rectangular transverse reinforcement SMF - - -
21.7.3.1 Type of column transverse reinforcement (hook/extension) SMF - - -
21.7.3.1 Maximum allowed column cross section center link leg spacing SMF - - -
21.7.3.1 Maximum allowed center hoop spacing SMF - - -
21.7.3.1 Spacing of column transverse reinforcement for non-structural extensions SMF - - -
21.7.3.2 Minimum column transverse reinf.with beams in all directions ≥ 3/4 the column’s width SMF - - -
21.7.4.1 Maximum nominal shear strength for joints confined by beams on all four faces SMF - - -
21.7.4.1 Maximum nominal shear strength for joints confined by beams on three faces or two opposite faces SMF - - -
21.7.4.1 Maximum nominal shear strength for joints not confined by beams SMF - - -
21.8.3 Minimum nominal strength of the strong connection for column-to-column connections SMF - - -
21.8.3 Minimum nominal moment strength of the strong connection for column-to-column connections SMF - - -
21.8.3 Minimum nominal shear strength of the strong connection for column-to-column connections SMF - - -
Note: