Skip to main content

Minimum area of shear reinforcement (concrete beam: ACI 318)

Modified: 2 Jun 2023 Tekla Structural Designer 2025
2025
Tekla Structural Designer

The minimum area of shear reinforcement required, Av,min is given by1;

Av,min = MAX (0.062* f`c0.5 *bw*s/ fyt , 0.35MPa*bw*s/ fyt, Av,min,u) metric units
= MAX (0.75* f`c0.5 *bw*s/ fyt , 50psi*bw*s/ fyt, Av,min,u) US units

where

s = the spacing of the shear reinforcement along the longitudinal axis of the beam
fyt = yield strength of transverse reinforcement
Av,min,u = the total minimum area of the shear reinforcement calculated from data supplied by the user i.e. maximum spacing across the beam, minimum link diameter and number of legs.

i.e. maximum spacing across the beam, minimum link diameter and number of legs

    

Footnotes

1 ACI 318-08, ACI 318-11, ACI 318M-08 and ACI 318M-11 Section 11.4.6.3
Submit

Table of Contents