Skip to main content

Minimum area of shear reinforcement (concrete beam: EC2)

Modified: 9 Nov 2026 Tekla Structural Designer 2025
2025
Tekla Structural Designer

The minimum area of shear reinforcement required, Asw,min, is given by:1

Asw,min = max[sl · ρw,min · bw, Asw,min,u]

where

  • sl = the spacing of the shear reinforcement along the longitudinal axis of the beam
  • Asw,min,u = the total minimum area of the shear reinforcement calculated from data supplied, i.e. maximum spacing across the beam, minimum link diameter, and number of legs
For design in accordance with:
  • EC2 Recommendations, UK NA, Irish NA, Malaysian NA, Singapore NA, Finnish NA, Swedish NA:

    ρw,min = (0.08 · √(fck)) / fyk

  • Norwegian NA:

    ρw,min = (0.1 · √(fck)) / fyk

Footnotes

1 EN 1992-1-1:2004 Section 9.2.2(5) Eqn (9.4)
Submit