An Apply NCCI PN002 checkbox is available on the Stud strength page of the Beam Properties. When this option is selected Tekla Structural Designer calculates partial shear limits described in PN002 for edge beams and SCI P405 for internal beams.
It should be noted that to obtain the benefits of this NCCI,
-
for all deck types and orientation the design live load (γq qk) is limited to 9 kN/m2
-
for all deck types and orientation the beam should be “unpropped” at the construction stage (this is a general assumption in Tekla Structural Designer for all composite beams).
-
for perpendicular trapezoidal decks the studs should be placed on the “favorable” side or in the central position.
-
for perpendicular trapezoidal decks the reinforcement is assumed to be above the head of the stud. Consequently, a reduction is made to the stud resistance in accordance with NCCI PN001.
-
for limits of maximum longitudinal stud spacing the relevant NCCI must be satisfied.
-
for slab the nominal total depth must not exceed 180mm (depth of concrete over the decking must not exceed 100mm)
-
for all deck profiles the nominal height (to shoulder) must not exceed 80mm (applies to SCI P405 only)
It is the user's responsibility to ensure compliance with the above since the program makes no check on these items.
For perpendicular trapezoidal decks the reduction in stud resistance to which point 4 above refers, will be conservative if the reinforcement is placed in a more favorable (lower) position. Even though the NCCI is relevant to the UK this option is also available for all Eurocode region codes in Tekla Structural Designer.
NCCI is not applicable where studs are “Shop welded” for Closed Ends decking.
More information is given in the PN001, PN002 and SCI P405 on www.steel-ncci.co.uk and on http://www.steelbiz.org/