Horizontal cantilever structural members in structures assigned to Seismic Design Category D, E or F are required to be designed to the applicable load combinations plus an isolated minimum net upward force of 0.2 times the dead load.
If a cantilever beam has been marked as a seismic cantilever, then provided the seismic design category = D, E or F the minimum design moment at the restrained end is checked as follows:
Calculate minimum positive design moment:
Mmin+ = 0.2 · Me,dead−
where
- Mmin+ = minimum positive design bending moment at the restrained end
- Me,dead− = critical negative bending moment at the restrained end due to dead loads only obtained for the considered seismic combination
Check the minimum design moment at the restrained end:
Mu+ ≥ Mmin+
where
- Mu+ = critical positive design bending moment at the restrained end obtained for the considered seismic combination
If the check fails, the region is designed for Mu+ = Mmin+.