The design value of the shear resistance of a concrete section with vertical shear reinforcement, VRd,max, is given by:
VRd,max = 0.9 · αcw · bw · d · v1 · fcwd / (cot θ + tan θ)
where θ = min{θmax, max[0.5 · sin−1[2 · VEd,max / (αcw · bw · 0.9 · d · v1 · fcwd)], θmin]}
where
- vEd = VEd,max / (bw · d)
- τEd = TEd,max / (2 · Ak · tef)
- Ak = (h − tef) · (bw − tef)
- tef = max(A / u, 2 · (h − do))
- A = h · bw
- u = the outer circumference of the cross-section
= 2 · (h + bw)
- do = the effective depth of the outer layer of longitudinal reinforcement
- VEd,max = maximum absolute value from all the shear regions
- TEd,max = maximum torsion on the member
The maximum design value of the torsional resistance moment, TRd,max, is given by:
TRd,max = 2 · v1 · αccw · fcwd · Ak · tef · sin θ · cos θ
For design in accordance with:
-
UK NA, Irish NA, Malaysian NA, Singapore NA:
fcwd1 = αccw · min(fck, 50 N/mm2) / γC
-
EC2 Recommendations, Finnish NA, Norwegian NA, and Swedish NA:
fcwd = αccw · fck / γC
-
EC2 Recommendations, UK NA, Irish NA, Malaysian NA, Singapore NA, Finnish NA, Norwegian NA, Swedish NA:
αcw = 1.0
γC = 1.5
v1 = 0.6 · (1 − fck / 250)
-
EC2 Recommendations, UK NA, Irish NA, Malaysian NA, Singapore NA, Swedish NA:
αccw = 1.0
-
Finnish NA, Norwegian NA:
αccw = 0.85
The design value of the torsional resistance moment of a concrete section with no shear reinforcement, TRd,c, is given by:2
TRd,c = 2 · Ak · tef · fctd
where the design tensile strength of the concrete, fctd = αct · fctk,0.05 / γC
-
EC2 Recommendations, UK NA, Irish NA, Malaysian NA, Singapore NA, Finnish NA, Swedish NA:
αct = 1.0
γC = 1.5
-
Norwegian NA:
αct = 0.85
γC = 1.5
If the maximum torsional moment acting on the beam, TEd,max, is less than the ignorable torque limit then no further calculations are necessary.
Otherwise:
IF (TEd,max,i / TRd,max) + (VEd,max,i / VRd,max) ≤ 1.0
THEN the torsion design process can proceed.
ELSE the torsion design fails since the section size is inadequate for torsion.
Footnotes