Design values of shear resistance and torsional resistance moment (concrete beam: EC2)

Modified: 9 Nov 2026 Tekla Structural Designer 2025
2025
Tekla Structural Designer

The design value of the shear resistance of a concrete section with vertical shear reinforcement, VRd,max, is given by:

VRd,max = 0.9 · αcw · bw · d · v1 · fcwd / (cot θ + tan θ)

where θ = min{θmax, max[0.5 · sin−1[2 · VEd,max / (αcw · bw · 0.9 · d · v1 · fcwd)], θmin]}

where

  • vEd = VEd,max / (bw · d)
  • τEd = TEd,max / (2 · Ak · tef)
  • Ak = (h − tef) · (bw − tef)
  • tef = max(A / u, 2 · (h − do))
  • A = h · bw
  • u = the outer circumference of the cross-section

    = 2 · (h + bw)

  • do = the effective depth of the outer layer of longitudinal reinforcement
  • VEd,max = maximum absolute value from all the shear regions
  • TEd,max = maximum torsion on the member

The maximum design value of the torsional resistance moment, TRd,max, is given by:

TRd,max = 2 · v1 · αccw · fcwd · Ak · tef · sin θ · cos θ

For design in accordance with:

  • UK NA, Irish NA, Malaysian NA, Singapore NA:

    fcwd1 = αccw · min(fck, 50 N/mm2) / γC

  • EC2 Recommendations, Finnish NA, Norwegian NA, and Swedish NA:

    fcwd = αccw · fck / γC

For design in accordance with:
  • EC2 Recommendations, UK NA, Irish NA, Malaysian NA, Singapore NA, Finnish NA, Norwegian NA, Swedish NA:

    αcw = 1.0

    γC = 1.5

    v1 = 0.6 · (1 − fck / 250)

For design in accordance with:
  • EC2 Recommendations, UK NA, Irish NA, Malaysian NA, Singapore NA, Swedish NA:

    αccw = 1.0

  • Finnish NA, Norwegian NA:

    αccw = 0.85

The design value of the torsional resistance moment of a concrete section with no shear reinforcement, TRd,c, is given by:2

TRd,c = 2 · Ak · tef · fctd

where the design tensile strength of the concrete, fctd = αct · fctk,0.05 / γC

For design in accordance with:
  • EC2 Recommendations, UK NA, Irish NA, Malaysian NA, Singapore NA, Finnish NA, Swedish NA:

    αct = 1.0

    γC = 1.5

  • Norwegian NA:

    αct = 0.85

    γC = 1.5

If the maximum torsional moment acting on the beam, TEd,max, is less than the ignorable torque limit then no further calculations are necessary.

Otherwise:

IF (TEd,max,i / TRd,max) + (VEd,max,i / VRd,max) ≤ 1.0

THEN the torsion design process can proceed.

ELSE the torsion design fails since the section size is inadequate for torsion.

Footnotes

1 Eqn (3.15) EN 1992-1-1:2004 Section 3.1.6(1)P
2 EN 1992-1-1:2004 Eqn (6.26) with τt,i = fctd