Longitudinal spacing, s, between the legs of shear reinforcement is given by:1
IF
Vu − ϕVc ≤ ϕ · 0.33 · f'c0.5 · bw · d (metric units)
Vu − ϕVc ≤ ϕ · 4 · f'c0.5 · bw · d (US units)
THEN
smin,u ≤ s ≤ min[0.5 · d, 600 mm (24 in), smax,u]
ELSE
smin,u ≤ s ≤ min[0.25 · d, 300 mm (12 in), smax,u]
where
- smax,u = the maximum longitudinal spacing specified by the user
- smin,u = the minimum longitudinal spacing specified by the user
Moreover IF compression reinforcement is required, the compression reinforcement shall be enclosed by ties2. This is an additional limit, not an alternative.
Vertical spacing of ties is then given by:3
s ≤ min(16 · db, 48 · db,w, bw, h)
where
- db = the nominal diameter of the bar
- db,w = the nominal diameter of the link reinforcement
Unlike other design codes, ACI 318 does not specify a limit for maximum spacing of link legs across a beam. However, attention is drawn to an ACI Structural Journal Technical Paper - “Shear Reinforcement Spacing in Wide Members”, which suggests a limit of around d.