Spacing of shear reinforcement (concrete beam: EC2)

Modified: 9 Nov 2026 Tekla Structural Designer 2025
2025
Tekla Structural Designer

The user defined spacing limits (as specified in Design Settings > Concrete > Cast-in-place > Beam > Link Settings) are considered in addition to the following EC2 or NA recommendations.

For design in accordance with:

  • UK NA, EC2 Recommendations, Irish NA, Malaysian NA, Singapore NA, Finnish NA, Swedish NA

    the longitudinal spacing, sl, between the legs of shear reinforcement is given by:

    sl,min,u ≤ sl ≤ min[0.75 · d, sl,max,u]

  • Norwegian NA:

    sl,min,u ≤ sl ≤ min[0.6 · h', sl,max,u]

where

  • sl,max,u = the maximum longitudinal spacing specified
  • sl,min,u = the minimum longitudinal spacing specified
  • h' = the distance between the centers of gravity of top and bottom reinforcement

If compression reinforcement is required for bending, the longitudinal spacing, sl, between the legs of shear reinforcement is given by:

sl,min,u ≤ sl ≤ min{min[sl,max,code, 15 · Φcomp], sl,max,u}

where Φcomp = the minimum diameter of the compression reinforcement

The transverse spacing, st, between the legs of shear reinforcement is given by:

st ≤ min[st,max,code, st,max,u]

where

  • st,max,u = the maximum link leg spacing across the beam specified by the user
  • st,max,code = an NDP for the maximum code allowed leg spacing across beam

For design in accordance with:

  • EC2 Recommendations, UK NA, Irish NA, Malaysian NA, Singapore NA, Finnish NA, Swedish NA:

    st,max,code = min[0.75 · d, 600 mm]

  • Norwegian NA:

    st,max,code = min[h', 600 mm]

    where h' = the distance between the centers of gravity of top and bottom reinforcement