Stress checks (SLS) (Composite beams: BS 5950)

Modified: 3 Oct 2019 Tekla Structural Designer 2025
2025
Tekla Structural Designer

Tekla Structural Designer calculates the worst stresses in the extreme fibres of the steel and the concrete at serviceability limit state for each load taking into account the proportion which is long term and that which is short term. These stresses are then summed algebraically. Factors of 1.00 are used on each loadcase in the design combination (you cannot amend these). The stress checks assume that full interaction exists between the steel and the concrete at serviceability state.