The following limitations currently apply:
-
Steel design for staged construction results has only been implemented for the AISC and Eurocode steel design codes.
-
No allowance for objects being removed. (e.g. propping during construction).
-
Multiple stage construction scenarios are not supported.
-
Creep during construction - in Tekla Structural Designer a simple approach has been adopted (based on simplified guidance from ACI codes).
-
Construction stage forces are not considered in design. (These are not expected to be controlling design conditions.)
-
There is no option to elevate loading levels to ultimate at intermediate construction stages.
As a result it is not possible to examine design conditions on partially completed structures (e.g. wind effects on a half built building). To investigate this scenario the workaround is to make a copy of the structure and cut it down to required size.