The following limitations currently apply:

  1. Steel design for staged construction results has only been implemented for the AISC and Eurocode steel design codes.

  2. No allowance for objects being removed. (e.g. propping during construction).

  3. Multiple stage construction scenarios are not supported.

  4. Creep during construction - in Tekla Structural Designer a simple approach has been adopted (based on simplified guidance from ACI codes).

  5. Construction stage forces are not considered in design. (These are not expected to be controlling design conditions.)

  6. There is no option to elevate loading levels to ultimate at intermediate construction stages.

    As a result it is not possible to examine design conditions on partially completed structures (e.g. wind effects on a half built building). To investigate this scenario the workaround is to make a copy of the structure and cut it down to required size.