'Unstaged' modification factors

A standard 'unstaged' 3D building analysis in Tekla Structural Designer is limited by the fact that the modification factors defined in the Analysis Settings dialog apply irrespective of the nature of the loading. For the majority of materials the factors default to 1.0, but for concrete different defaults apply, which vary depending on the design code.

If working to ACI/AISC the 'unstaged' defaults are:

If working to Eurocodes the 'unstaged' defaults are:

In the absence of any more rigorous approach these factors are deemed to cater for creep and cracking effects in concrete to a degree that is sufficient for 2nd order analysis at ULS design load levels. Clearly this is very simplistic because both creep and cracking are load dependent, so the use of a single factor for all load combinations, and also for the service and ultimate load levels in any single combination can never be “correct”.

Staged construction modification factors

By adopting a staged construction approach the load dependent nature of creep and cracking in concrete can be catered for.

This is achieved as follows:
  • A single set of 'Construction Stage' modification factors are specified for all of the construction stages.
  • Five separate sets of 'Design Stage' modification factors are specified appropriate to the persistent or transient nature of loading, and also to the service or ultimate load level.
  • Unlike the solver models used for other analysis types, the staged construction solver model is split into a series of construction stages and design stages, with the section properties of elements in each stage having modification factors applied appropriate to that stage.
    • Each of the construction stages use the same set of 'Construction Stage' modification factors in the solver model. Only those members assigned to the selected construction stage and previous stages are included in the solver model for that stage.
    • Each of the design stages use the appropriate 'Design Stage' modification factors for that particular stage in the solver model. Because the design stages occur after the end of construction, all members are included in the solver model for each of the design stages.
    • To see the effect of the modification factors, select a solver element in the solver model. In the Properties window the section/material properties update accordingly as you move from one stage to the next.
  • The 'Staged Construction' load combination is analyzed for each construction stage solver model using the same 'Construction Stage' modification factors.
  • The remaining load combinations are analyzed for the appropriate design stage solver model using the appropriate 'Design Stage' modification factors, (load combinations having been automatically assigned to Design Stages according to the loadcases they contain.)

The Construction Stage defaults are:

Note:

Creep during construction is catered for separately by an adjustment to the E and G values assigned to each member at each construction stage, (based on the age of the member at that stage). For details of how this is calculated, see: Concrete creep allowance during construction stages

The 'Persistent Loading - Strength' Design Stage defaults are:

Note:

The default factors shown above have an allowance for creep built in.

The 'Persistent Loading - Service' Design Stage defaults are:

Note:

The default factors shown above have an allowance for creep built in.

The 'Transient Loading - Strength' Design Stage defaults are:

The 'Transient Loading - Service' Design Stage defaults are:

The 'Seismic Loading' Design Stage defaults are:

Use of modification factors in sway and drift checks:

Staged construction analysis enables assessment of drift using short term properties and member design using long term properties in a single design process as follows:

  1. Enable staged construction analysis for design

    • This means that the analysis for gravity design uses the relevant “persistent loading - strength” modification factors and hence analysis results at the relevant level of 2nd order effects.

    • An added benefit is that analysis for ULS design of (transient classed) wind combinations uses the transient modification factors and hence potentially reduced 2nd order effects.

  2. Edit the building analysis modification factors to values relevant for wind (or seismic) assessments* then run a single design process.
    • *The recommendation is that these are reset to be the same as those for staged construction analysis “transient loading-service” or “seismic loading”
      • Note that by default these factors are the same (based on ACI guidance).

    • Both Wind and Seismic (ELF) drift checks are based on the analysis of wind loads in isolation. Staged construction analysis does not (cannot logically) solve individual loadcases, so the loadcase results used for wind drift continue to derive from the building analysis. With the adjusted factors these checks will be less onerous (as desired).