Skip to main content

Engineering library update (May 2025)

Modified: 17 Jun 2025 Tekla Tedds 2025
2025
Tekla Tedds Tekla Tedds for Word

American Design

Product bulletin April 2025 (PBT-2504-1)

Seismic forces (ASCE7) - Corrected a potentially un-conservative error affecting seismic force calculations with Site Class E and a mapped acceleration parameter at short period, Ss, between 0.75 and 1.0 specified.

For more detailed information please refer to Product bulletin April 2025 (PBT-2504-1).

New verification examples

New verification examples are available from the Engineering Library Index for the calculations below. Detailed documentation is provided in the Tedds Product Guide for each example.

  • Wood 2D analysis & design (NDS)

    Wood member analysis & design (NDS)

    Wood member design (NDS)

    • Axial Compression of Wood Column (ASD) verification example

    • Glulam Beam Design (ASD) verification example

  • Wood shear wall design (NDS)

    • Wood Shear Wall - Segmented (with GWB) – Wind verification example

    • Wood Shear Wall - Segmented (without GWB) – Wind verification example

    • Wood Shear Wall - Segmented – Seismic verification example

    • Wood Shear Wall - Perforated (with GWB) – Wind verification example

    • Wood Shear Wall - Perforated (without GWB) – Wind verification example

    • Wood Shear Wall - Perforated – Seismic verification example

Other updates

Retaining basement wall analysis & design (ACI318)
TEDDS-9054 Fixed shear strength of the wall being underestimated for walls with one layer of reinforcement that were fully in either negative or positive bending.
Seismic forces (ASCE7)
TEDDS-8876 Fixed index out of error related to the default precision format when designing to ASCE 7-22.
TEDDS-8517 Update to include ASCE 7-16 Supplements 1, 2, and 3.
Wind loading (ASCE7)
TEDDS-9480 Fixed undefined tornado variable for envelope method with parapet.

Australian Design

No updates.

British Design

No updates.

Canadian Design

No updates.

Eurocode Design

Product bulletin April 2025 (PBT-2504-3)

Timber member design (EN1995) - Fixed a potentially un-conservative error affecting the shear calculation of notched sections.

For more detailed information please refer to Product bulletin April 2025 (PBT-2504-3).

Product bulletin April 2025 (PBT-2504-2)

Foundation analysis & design (EN1992/EN1997) - Fixed a potentially un-conservative error affecting the calculation of punching shear check.

For more detailed information please refer to Product bulletin April 2025 (PBT-2504-2).

Other Updates

Column base plate design (EN1993)
TEDDS-9435 Enhanced calculation to allow internal anchors for I-sections pinned connections.
Foundation analysis & design (EN1992/EN1997)
TEDDS-9085 Corrected passive pressure coefficient for undrained soils.
RC pile cap design (EN1992/EN1997)
TEDDS-9016 Fixed wrong default reliability factor when designing to the Swedish NA.
TEDDS-9404 Fixed undefined variable error triggered when handling not supported moments about the x-x axis for 2-pile pilecaps.
Steel beam analysis & design (EN1993)
TEDDS-9366 Amended calculation to ensure high shear is reported as being beyond scope except for I beams and channel sections.

Steel 2D analysis & design (EN1993)

Steel member analysis & design (EN1993)

Steel member design (EN1993)

TEDDS-9084 Corrected undefined variable error, A_{eff}.
Submit