Tekla Tedds Engineering Library update (May 2025 - version 27.02) is available in Trimble Downloads.
American Design
Product bulletin April 2025 (PBT-2504-1)
Seismic forces (ASCE7) - Corrected a potentially un-conservative error affecting seismic force calculations with Site Class E and a mapped acceleration parameter at short period, Ss, between 0.75 and 1.0 specified.
For more detailed information please refer to Product bulletin April 2025 (PBT-2504-1).
New verification examples
New verification examples are available from the Engineering Library Index for the calculations below. Detailed documentation is provided in the Tedds Product Guide for each example.
-
Wood 2D analysis & design (NDS)
Wood member analysis & design (NDS)
Wood member design (NDS)
-
Axial Compression of Wood Column (ASD) verification example
-
Glulam Beam Design (ASD) verification example
-
-
Wood shear wall design (NDS)
-
Wood Shear Wall - Segmented (with GWB) – Wind verification example
-
Wood Shear Wall - Segmented (without GWB) – Wind verification example
-
Wood Shear Wall - Segmented – Seismic verification example
-
Wood Shear Wall - Perforated (with GWB) – Wind verification example
-
Wood Shear Wall - Perforated (without GWB) – Wind verification example
-
Wood Shear Wall - Perforated – Seismic verification example
-
Other updates
| Retaining basement wall analysis & design (ACI318) | |
|---|---|
| TEDDS-9054 | Fixed shear strength of the wall being underestimated for walls with one layer of reinforcement that were fully in either negative or positive bending. |
| Seismic forces (ASCE7) | |
|---|---|
| TEDDS-8876 | Fixed index out of error related to the default precision format when designing to ASCE 7-22. |
| TEDDS-8517 | Update to include ASCE 7-16 Supplements 1, 2, and 3. |
| Wind loading (ASCE7) | |
|---|---|
| TEDDS-9480 | Fixed undefined tornado variable for envelope method with parapet. |
Australian Design
No updates.
British Design
No updates.
Canadian Design
No updates.
Eurocode Design
Product bulletin April 2025 (PBT-2504-3)
Timber member design (EN1995) - Fixed a potentially un-conservative error affecting the shear calculation of notched sections.
For more detailed information please refer to Product bulletin April 2025 (PBT-2504-3).
Product bulletin April 2025 (PBT-2504-2)
Foundation analysis & design (EN1992/EN1997) - Fixed a potentially un-conservative error affecting the calculation of punching shear check.
For more detailed information please refer to Product bulletin April 2025 (PBT-2504-2).
Other Updates
| Column base plate design (EN1993) | |
|---|---|
| TEDDS-9435 | Enhanced calculation to allow internal anchors for I-sections pinned connections. |
| Foundation analysis & design (EN1992/EN1997) | |
|---|---|
| TEDDS-9085 | Corrected passive pressure coefficient for undrained soils. |
| RC pile cap design (EN1992/EN1997) | |
|---|---|
| TEDDS-9016 | Fixed wrong default reliability factor when designing to the Swedish NA. |
| TEDDS-9404 | Fixed undefined variable error triggered when handling not supported moments about the x-x axis for 2-pile pilecaps. |
| Steel beam analysis & design (EN1993) | |
|---|---|
| TEDDS-9366 | Amended calculation to ensure high shear is reported as being beyond scope except for I beams and channel sections. |
|
Steel 2D analysis & design (EN1993) Steel member analysis & design (EN1993) Steel member design (EN1993) |
|
|---|---|
| TEDDS-9084 | Corrected undefined variable error, A_{eff}. |