Skip to main content

Troubleshooting: Not all protections are visible in the panel schedule

Modified: 21 May 2026 Stabicad
Not version-specific
Stabicad
Problem: After generating a panel schedule in AutoCAD, not all protections appear to be visible.
Cause: The visibility of specific protections from the power module might be disabled in the general project or profile settings within StabiBASE.
Solution: The visibility of these protections can be modified through the drawing settings:
  1. Open StabiBASE.
  2. Right-click on the Profile or Project to which the setting should be applied.
  3. Choose Drawing settings (Tekeninstellingen) from the context menu.
  4. Navigate in the tree structure to the category Electrical (Elektro) > Manage Installation (Beheren Installatie).
  5. Locate the setting Show power module (Toon krachtmodule) and change the value to Yes (Ja).
  6. Regenerate the panel schedule in your drawing; the protections will now be visible
Submit