TSAC-10065 |
Concrete components |
Embedded anchors (008): Sometimes, the anchors were created on the wrong face of the main part due to the complicated shape of the part. This issue has been fixed. |
|
TSAC-10086 |
Concrete components |
Reinforced concrete stair (95): The bending radius of rebars A, I, and J is now properly set from the rebar database. |
|
TSAC-10093 |
Concrete components |
The Continuous beam reinforcement macro now works correctly again. |
|
TSAC-9774 |
Concrete components |
Strip footing reinforcement (75): The main bar bending radius is now properly set using the value defined in the rebar database. |
|
TSAC-9865 |
Concrete components |
Reinforced concrete stair (95): Previously, when steps had small chamfers and ridges were created, the ridges were not properly formed. This issue has been fixed. |
|
TSAC-9872 |
Concrete components |
Corbel reinforcement (81): Previously, rebars were sometimes created with incorrect properties or grade. This issue has been fixed. |
|
TSAC-10057 |
Steel components |
Haunch (40): Previously, when switching the haunch type between a profile haunch and welded plates haunch, the position of compression stiffeners was changing. This issue has been fixed. |
|
TSAC-10091 |
Steel components |
Partial stiffened end plate (65): Previously, shear tab chamfers were not created when you had selected to create chamfers, but did not specify any values. This issue has been fixed. |
|
TSAC-10124 |
Steel components |
Hollow brace wraparound gusset (59): Previously, it was not possible to set the bolt assembly type for the brace bolts on the brace side. This issue has been fixed. |
|
TSAC-10132 |
Steel components |
End plate (144): Previously, unwanted horizontal stiffeners were created when a seat plate was used. This issue has been fixed. |
|
TSAC-10151 |
Steel components |
Cage ladder (S60): Previously, when you defined to cut stringers into segments with a certain maximum length and the stringers were created as polybeams, some segments were created with an incorrect length. This issue has been fixed. |
|
TTSD-75464 |
Import, export, interoperability |
IFC4 and TrimBIM export: The MAIN_PART property was not exported correctly in the IFC4 and TrimBIM exports. This issue has been fixed. |
|
TTSD-76009 |
Import, export, interoperability |
IFC4 and TrimBIM export: All nut type and number properties are now exported in the TrimBIM and IFC4 export. |
|
TTSD-76186 |
Import, export, interoperability |
IFC4 export: Property set filters for rebar sets now work for the IFC4 export. |
|
TTSD-75669 |
Templates and reports |
Templates in marks: Previously, it was not possible to use the CURRENT_DRAWING.SIZE attribute in mark templates. This issue has now been fixed. |
|
TTSD-76093 |
Templates and reports |
Template Editor: Sometimes modifying a template object, for example a line, in the property dialog could result in an empty template. This issue has been fixed. |
|
TSAC-9290 |
Drawings |
Previously, when you defined a rotation for a symbol in a drawing, the drawing grid labels were also rotated when you clicked Modify in the Advanced grid label properties dialog. This issue has been fixed. |
|
TSAC-9690 |
Drawings |
Advanced grid labels: Now the customized grid labels are always placed according to the positioning settings defined in the Advanced grid label properties dialog. Previously, changing some settings in the dialog could change the label positions. |
|
TTSD-72801 |
Drawings |
Previously, in certain cases, some circular or arc lines of circular radial grids were missing from drawings. This issue has been fixed. |
|
TTSD-73659 |
Drawings |
Previously, circular or in other ways curved cuts or outer edges in pour objects were not displayed correctly in reflected views in drawings. This issue has been fixed. |
|
TTSD-74297 |
Drawings |
View-based dimensioning: When creating automatic view-level dimensions for rebars using integrated dimensions as the dimensioning type, the created dimensions are now correctly aligned perpendicularly to the rebars. |
|
TTSD-74676 |
Drawings |
Symbols that contain long texts now work more reliably in drawings. |
|
TTSD-74864 |
Drawings |
Create fabrication drawings (local): Creating fabrication drawings for cast units did not always work when you had selected the cast units using the Select parts selection switch and disabled the Creation review dialog. This issue has been fixed. |
|
TTSD-75171 |
Drawings |
Earlier, circular lines of circular radial grids were not shown in drawings. This issue has been fixed. |
|
TTSD-75941 |
Drawings |
Aligning drawing marks to a point: Previously, when aligning drawing marks to a point using the Align to a point command, if you picked the point inside another view, the drawing stopped showing the selected objects with selection highlight. This issue has been fixed. |
|
TTSD-75949 |
Drawings |
Previously, some hatches in drawing templates were not printed correctly. This issue has been fixed. |
|
TTSD-76030 |
Drawings |
Fabrication drawings (local): Previously, in the Creation review dialog, the top-matching templates and the top-matching templates with multiple sheets grouped together were not always sorted. Now, both the top-matching templates and the top-matching templates with multiple sheets grouped together are always sorted in ascending order. |
|
TTSD-76195 |
System and options |
The -a option to rename .tsep files has been re-enabled in TeklaExtensionPackage.BatchBuilder.exe. |
|
TTSD-76610 |
Tekla Model Sharing |
Tekla Model Sharing: Building hierarchy is now handled faster at read in. |
|
TTSD-75247 |
Reinforcement |
Rebar shape recognition: The maximum limit on Extra point shortening has been removed (for example, XS_REBAR_RECOGNITION_EXTRA_POINT_SHORTENING set to 2.56 mm). |
|
TTSD-70916 |
Modeling |
Fixed an issue where entering invalid values in the grid property pane caused Tekla Structures to stop working unexpectedly. |
|
TTSD-72102 |
Modeling |
Previously, it was not possible to change the material thickness of FP_Y or GYBA folded plates. This issue has now been fixed in environment installers. |
|
TTSD-75102 |
Modeling |
Previously, CUSTOM. properties were not included when exporting to TrimBIM (.trb) format. This has been fixed. |
|
TTSD-75282 |
Modeling |
When using the Tab key to move between fields in the property pane, the text in the fields is now correctly selected. |
|
TTSD-76211 |
Modeling |
Building hierarchy: Site, building, and building storey name can now contain 61 characters. |
|
TTSD-76239 |
Modeling |
Trimble Visualizer has been updated to a newer version. |
|
SOLD-2921 |
Licensing |
License Management Improvement: Closing Tekla Structures no longer triggers a "Failed to return license" error message if the license has already been released by another concurrent session of the same version. |
|
TTSD-67795 |
Licensing |
The Exit dialog has been updated to make the option to keep the license reserved easier to understand. |
|
TTSD-75521 |
Core |
Previously, when you selected Close window on the Tekla Structures icon in the Windows taskbar, Tekla Structures could stop working unexpectedly instead of shutting down. This issue has been fixed, and Tekla Structures stability has been improved. |
|
TTSD-76629 |
Tools and components |
Earlier, in some rare cases, Tekla Structures might stop working unexpectedly when working with rebars in system components. This issue has been fixed. |
|
TTSD-68821 |
Import, export, interoperability (steel) |
STEP/IGES export: Tapped holes are now properly exported with the core hole size. |
|
TTSD-70546 |
Import, export, interoperability (steel) |
STEP/IGES export: Previously, if you did not enter an export file name, the export did not run. Now, you receive a visual notification when the export file name is missing. |
|
TTSD-75019 |
Import, export, interoperability (steel) |
STEP/IGES export: Bolt holes now extend completely through the material. |
|
TTSD-75394 |
Import, export, interoperability (steel) |
STEP/IGES export: Slotted bolt holes with an offset are now exported properly with the correct offset. |
|
TTSD-75492 |
Import, export, interoperability (steel) |
DSTV/NC: Previously, when you exported a polybeam plate with cuts where the width was greater than the length, and the advanced option XS_USE_NEW_PLATE_DESIGNATION was set to a value that required switching the width and length, the bending lines were created in an incorrect position. This issue has been fixed. |
|
TSAC-9860 |
Import, export, interoperability (concrete) |
Export ELiPLAN file (68): Previously, some cuts and recesses were exported with a shift from their modeled positions. This issue has been fixed. |
|
TSAC-9949 |
Import, export, interoperability (concrete) |
Export ELiPLAN file (68): The accessory code for plotter objects is now exported only once per object in the record with the longest line segment. Previously, with complex cuts or openings translated into line segments, each line segment had its own accessory information. |