Overslaan en naar de inhoud gaan

Drawing definer (DR001)

Tekla Structures - Not version-specific
Not version-specific
Tekla Structures
Environment
Construsoft European
Netherlands
Image
DR001

The Drawing Definer is a collection of independently working tools for adding recurring actions to drawings. Most of the tools are related to adding dimensions, symbols or changing view properties and they are arranged in a toolbar.

Dialog box

The various tools are grouped together in one dialog box that looks like a toolbar. The Drawing Definer dialog box:

Image
02

 

Run a tool on multiple drawings

The Definer tools can be executed on one (opened) current drawing, on a number of drawings (selected in the drawing list) or on all drawings.

Image
03

Tools selection

If you move the mouse cursor over one of the buttons, the text with the name of the tool appears.

Image
4

 

To run multiple tools at the same time, click on the buttons of the Definer tools. The active buttons are displayed.  For running selected tool simultaneously, click the "Run the selected tools": 

Image
5

 

 

Image
6

 

Status bar

With multiple active tools and multiple drawings, it may take some time for all commands to be executed. A toolbar provides an indication of the time remaining.

Image
7

Cancel process

It is possible to cancel a running process. After pressing the "Run the selected tools" button, icon is changed. Clicking on the Stop sign will cancel the running process.

Image
8

Turn on/off tools in the toolbar

You can define which tools should be visible in the Drawing Definer toolbar. Tools you do not use can be turned off.
In the CS_DrawingDefinerCfg.xml, you can use parameter:
<add key="VisibleTools" value="11111111111111" /> by means of a 1 (on) or a 0 (off) you can indicate whether a tool should be visible in the toolbar.
To do this, open the *.xml file with a text editor (e.g. Wordpad or Notepad).
You should close the Drawing Definer program before making any changes to the *.xml file.

Image
9
Value letterTool name
AGridDim 
BDimTopView 
CTopViewDepth 
DSetAbsDim 
ECreateSymbols 
FDimCOG 
GDimConcreteView 
HDimConcreteView2 
ISymbolCastMoldSide 
JSymFoundationPiles 
KLoadViewSettings 
LCurvedDimlines 
MDepositMarks 
NWizard 


Configuration

Each definer tool comes with a configuration file, in this file you can define your personal settings for the various tools. When you run the Drawing Definer for the first time in Tekla Structures, a configuration file is created with default values. The configuration files are stored in the model folder attributes with the name: standard .csoft.d.tool name. Custom files can be copied to the TS folder if necessary so that they can be used in all models. You can open the configuration files with a text editor, for example Notepad.

 

Working with different tool presets

It is possible to work with different configuration files. For example, for the DimConcreteView tool, you may have created a configuration to size walls and also a file for columns, and one for bars, etc. 
Now rename the default configuration file "standard. csoft.d.dimconcreteview" to the desired application. (Save as...).
In the name of the file before ".csoft", name the application. E.g.: "wall.csoft.d.dimconcreteview" or "bar.csoft.d.dimconcreteview".
Now right click on an icon of the Drawing Definer toolbar, the available configuration files will be shown.

Image
10

Then the desired configuration file can be selected with the left mouse button. When the tool is executed then the selected configuration is used.
The location where configuration files can be located and the hierarchy is the same as for Tekla Structures files.
Priority from high to low: Attributes folder of the model folder > XS_PROJECT folder (TS folder) > XS_FIRM folder >XS_SYSTEM folder.
It is also possible to display the entire pathname of the available settings. In that case, set the following parameter to "True" in file "CS_DrawingDefinerCfg.xml":

<add key="ContextMenuFileFullPath" value="True" />

 

Open configuration files

Configuration files can be opened directly from the Drawing Definer toolbar. Right-click an icon in the toolbar and the available configuration files are displayed. Right-click on a configuration file and the corresponding file is opened directly.

Image
11

View name

Many definer tools look for the view name on the drawing to execute the command in that view. So this view name needs to be filled in in the drawing properties under the View button in the Label tab. If you do not want to see these names in the drawing you can set the color to invisible.

 

Tools overview

IconTool nameDescription
Image
12
DimTopViewDimension Top view
Image
13
TopViewDepthTop view depth
Image
14
CreateSymbolsCreate Symbols
Image
15
DimCOGIndicate Center of Gravity
Image
16
SymbolCastMoldSideSymbols placing at delivery site
Image
17
DimConcreteViewDimension concrete view 1
Image
18
DimConcreteView2Dimension concrete view 2
Image
19
SetAbsDimSet absolute dimensions
Image
20
GridDimSet grid dimensions
Image
21
SymFoundationPilesPiles foundation symbols
Image
22
LoadViewSettingsLoad view settings
Image
23
CurvedDimlinesCurved lines dimensions
Image
24
DepositMarksRemove and reposition marks
Image
25
WizardApply multiple settings simultaneously to multiple drawings

 

 

Description of Drawing definer tools

 

 

DimTopView

Application: To measure the concrete contour and cast in place  in a named window including any upstands and ridges.

 

Example:

Image
26

 

Config file: standard.csoft.d.dimtopview

Values can be defined in configuration files. First the application is described in quotes, then after value= in quotes the desired value can be defined.

 

Parameters:
<add key="NameOfTopView" value="Top View" />
Define the view name in which the tool is to be executed.

 

<add key="DistanceDimLinePrimary" value="20" />
Define the distance between the vertical dimension line indicating the concrete main dimensions relative to the concrete contour.

 

<add key="DistanceDimLineInsert" value="5" />
Define the distance of dimension lines from insert.

 

<add key="StartDistanceHorizontalDimensionLineBottom" value="20" />
Define the distance of the initial horizontal dimension from the concrete contour.

 

<add key="StepDistanceHorizontalDimensionLine" value="7" />
Define the step distances of the horizontal dimension lines.

Image
27

 

<add key="DimAllInserts" value="False" />
Determine whether, in addition to the concrete contour, inserts can also be measured (value="True") or not (value="False").

 

<add key="DimInsertIfInMiddleOfTopView" value="True" />
Determine whether inserts that are in the center of the element should be measured
(value="True") or not (value="False").

 

<add key="DimInsertToCastAndMoldSide" value="True" />
Determine whether dimension lines are to be placed over the entire width of the insert (value="True") or whether only a dimension line from the box side to the insert is to be placed (value="False")

Image
28

 

However, a constant "Sections" can be defined allowing the DimTopView tool to measure in (multiple) sections as well. Place a ";" between the window names to define multiple names.

<add key="NameOfTopView" value="Top View;Sections" />

 

<add key="DimIgnore_00" value="Dummy" />
Define which sections do not need to be dimensioned. Filter on the name of sections. If more than one part should not be sized, this line can be copied. Let the numbers of copied lines always increase by 1. For example:

<add key="DimIgnore_00" value="Chimney Anchor" />
<add key="DimIgnore_01" value="Stem Anchor" />

 

<add key="DimLineDimensionType" value="0" />
Determine the method of dimensioning. Option to dimension with intermediate dimensions
(value="0") or with counting through (value="1")
 

TopViewDepth


Application: adjusting the window depth of the top view. In regular generated drawings the full height of the wall is shown in the viewing depth of the top view of the wall. In the configuration file a value can be specified to set how large the viewing depth should be.
 

Example:  

Before running the tool:

Image
30

After running tool:

Image
31

Configuration file: standard.csoft.d.topviewdepth
 

Parameters:

 

<add key="TopViewDepthValue" value="100" />
Determines the depth of the visibility window. Increasing or decreasing this value makes more or fewer parts visible in the top view.

 

The value filled in for view enlargement for connecting parts is not taken into account for the "TopViewDepth-value". For an optimal functioning of this parameter it is recommended to work with a view magnification of 0.

 

<add key="NameOfTopView" value="Top View" />
Define the name of the View in which the tool is to be executed. Enter this name in quotes after value=

 

CreateSymbols

Application: Placing symbols to indicate the cast or box side of the formwork.
Example:

Before running the tool:

Image
32

After running the tool:

Image
33

 

Config file: standard.csoft.d.createsymbols
 

Parameters:
 

<add key="NameOfFrontView" value="Top view" />
Define the name of the view in which the symbols are to be placed.

 

<add key="SymbolSize" value="6" />
Define the size of the symbol that will be placed on the items.

 

<add key="EmbedName_00" value="Embed1;Embed2" />
Determine the name of the items where a symbol is to be placed.

 

<add key="SymbolFrontSide_00" value="concrete@48" />
Define the symbol to be placed at the location of parts at the front of the View.

 

<add key="SymbolBackSide_00" value="concrete@48" />
Define the symbol to be placed in place of parts at the rear of the View.

 

For the above parameters, use _00 count-through numbers to assign different symbols for different dimension embeds to assign different symbols.

DimCOG

Application: Placing a symbol, dimension line and text at the center of gravity mark in a named window measured from the origin of the drawing (left side element)
 

Example:

Image
34

 

Config file: standard.csoft.d.dimcog

 

Parameters: 

 

<add key="NameOfTopView" value="Top View" />
Define the name of the view in which to place the symbols and dimension lines.

 

<add key="SymbolOfCOG" value="concrete@64" />
Define the symbol to be placed at the location of the center of gravity.
The part before @ is the name of the symbol file, the part after @ is the number of the symbol in the given file.

 

<add key="SymbolHeight" value="10" />
Define the size of the defined symbol

 

<add key="LabelInsertionDeltaX" value="0" />
Determine the displacement in the X direction of the text label with respect to the center of gravity.
The value entered is multiplied by the scale of the View.

 

<add key="LabelInsertionDeltaY" value="14" />
Determine the displacement in the Y direction of the text label relative to the center of gravity.
The value entered is multiplied by the scale of the View.

 

<add key="DrawDimLineToCOG" value="True" />
Determine if a dimension line should be placed next to the symbol and text label. 
Option to place a dimension line (value="true") or no dimension line (value="false").
 

SymbolCastMoldSide

Application: Placing a symbol at the cast and/or mold side of an element in a named window (default "Top view"). You can define the symbol file and size in the configuration file. The cast side as such is not yet recognized by the tools, but assuming that the coordinate system for walls is set to "fixed", then the dumping side in the top view is the bottom side. In drawing settings where the coordinate  system is not set to "fixed", check carefully that the positioning of the symbols is correct.

 

Example:

Image
35

 

Config file: standard.csoft.d.symcastmoldside

 

Parameters: 


<add key="DrawSymbolOnCastside" value="True" />
<add key="DrawSymbolOnMoldside" value="False" />
Determine whether symbols are to be placed on the CastSide and/or the and/or the MoldSide

 

<add key="SymbolOfCastside" value="concrete@10" />
<add key="SymbolOfMoldside" value="concrete@155" />
Determine which symbols should be placed. (NameSymbolFile@Number)

 

<add key="SymbolOfCastsideHeight" value="9" />
<add key="SymbolOfMoldsideHeight" value="10" />
Determine the size of the symbols to be placed.
 

DimConcreteView

Application: Measurement of the contour of an part and any existing form of inserts in a named window. (Default "Front view") For sizing the dimension embeds various settings can be defined in the configuration file.

Filtering can be done on the name of the precast parts subassemblies. Based on that how the subassemblies should be measured.

 The dimensioning options are:
- DimIgnore: Do not take measurements
- DimOneRef: Measure one point (this is the yellow starting point of the insert)
- DimTwoRef: Measure two points (the yellow begin point and the purple end point)
- DimMiddleRef: Measure a point in the middle (the middle between the starting point and the
  start point and end point)

Because the reference points of the inserts in the model are taken into account when sizing the precast parts, it is recommended to model these subassemblies without offsets.

Example:

Image
36

Most of the inserts embeds/subassemblies will be able to be sized with a single point. Therefore, the last line in the configuration file standard.csoft.d.dimconcreteview is filled in with wildcard:
<add key="DimOneRef_01" value="*" />

Subassemblies that need to be dimensioned differently can be defined above this line in the configuration file.

 

Config file: standard.csoft.d.dimconcreteview

 

Parameters:


 <add key="NameOfFrontView" value="FrontView" />
Define the name of the view in which the tool should measure. A wildcard may be placed with this name, for example:

 

<add key="NameOfFrontView" value="Front*" />. It is possible to define multiple views. In that case place a ";" between the view names, e.g:
<add key="NameOfFrontView" value="Front view;Top view" />

 

<add key="StartDistanceHorizontalDimensionLineTop" value="13" />
<add key="StartDistanceHorizontalDimensionLineBottom" value="15" />
<add key="StartDistanceVerticalDimensionLineLeft" value="13" />
<add key="StartDistanceVerticalDimensionLineRight" value="15" />
Determine the start position of the dimension lines relative to the outer contour of the concrete element.
You can specify the spacing in four directions: Top (top), Bottom
(Bottom, Left and Right. The specified value is multiplied
by the scale of the view.

 

<add key="StepDistanceHorizontalDimensionLine" value="7" />
<add key="StepDistanceVerticalDimensionLine" value="7" />
Determine the space between the dimension lines. You can define the spacing between the Horizontal (horizontal) and Vertical (vertical) dimension lines. The specified value
is multiplied by the scale of the view.

 

<add key="NoDimLineIfDistanceSmallerThan" value="36" />
Define the limit which prevents small dimension lines from being placed because it may occur that the system points of the cast in place fall into the concrete contour. Lines that are smaller than the specified value will not be measured.
 

Example:

Image
37

 

Image
38

 
 

<add key="DimLineDimensionType" value="0" />
Define the method of dimensioning. Option to measure with intermediate measurements (value="0") or with counting through (value="1")

 

Example:

Image
39

 

<add key="DrawDimlinesMatSteel" value="True" />
<add key="DrawDimlinesMatConcrete" value="True" />
<add key="DrawDimlinesMatOthers" value="True" />
Determine which material groups are to be measured. You can choose to measure (value="True") or not (value="False") materials from Steel (steel group), Concrete (concrete group) or Others (miscellaneous group).

 

<add key="DrawDimlinesDiscontinuities" value="True" />
Determine whether discontinuites (openings, etc.) in the concrete form should be measured. Option to measure (value="True") or not measure (value="False").
Example: False / True

Image
42

 

<add key="DrawDimlinesTotal" value="True" />
Determine if the total dimensions of the concrete contour should be measured. Total dimensions to be measured (value="True") or not (value="False").

Example: True / False

Image
43

 

<add key="DrawHorTotalDimBottom" value="True" />
<add key="DrawVertTotalDimLeft" value="True" />
Define where the total dimensions of the concrete mark should be placed, for the horizontal total dimension and the vertical total dimension. If value="False" then the total dimensions are placed above and to the right of the mark respectively.

 

<add key="DrawSubAssembliesInfo" value="False" />
Determine if the subassemblies info should be placed on the dimension line. Option to place (value="True") or not (value="False") subassemblies info on the dimension line.

 

Tag info will be on the dimension line tags. This is not modifiable at this time. In case you want the info in the dimension line tags then add it manually, whether or not using the routine "CS_PlaceDimTags" which fills in tags from multiple selected dimension lines.

 

<add key="DimIgnore_00" value="Dummy" />
Filter by the name of items which should not be measured. Copy the line to apply multiple filters. Leave the number after "DimIgnore_" always increase by one (DimIgnore_01, DimIgnore_02, etc.).
Filter by the name of items which should be sized with 2 points. Copy the line to apply multiple filters.
Always let the number after DimTwoRef increase by 1.

 

<add key="DimMiddleRef_00" value="Weld plate" />
Filter by the name of items which should be sized in the middle.
Subassembly nfo is placed on the dimension line and not in the dimension line tags.
This is not possible at this time. In case you want the info in the dimension line tags then add it manually, whether or not using the routine "CS_PlaceDimTags" which fills in tags from multiple selected lines.
of multiple selected lines.

 

<add key="DrawDimlinesOpeningAnchors" value="True" />
Determine whether the anchors should be sized (value="True") or not (value="False").

 

<add key="MaxDistanceAnchorToOpening" value="60" />Determine the search area around recesses within which to look for anchors present. If the distance from the anchor to the contour of the recess is greater than the specified value, the anchor will not be measured.

 

<addkey="DistanceHorizontalDimensionLineOpeningAnchor" value="90">
Define the distance from the anchor in the upper right corner where the dimension line is to be placed.

Image
44

 

<add key="NameOpeningAnchor_00" value="Anchor" />
Define the name of the anchors around recesses that are to be sized. This parameter overrides any "DimIgnore" settings with the same name filter. This parameter can be copied as desired, let the number of the name always increase with 1: "NameOpeningAnchor_01", etc.

 

<add key="DrawLabelForOpeningAnchors" value="True" />
Determine whether to place (value="True") or not (value="False") label at the anchor in the opening.
Note: this is a text label with the assembly number of the anchor as text. 

 

<add key="LabelOpeningAnchorInsertionDeltaX" value="10" />
<add key="LabelOpeningAnchorInsertionDeltaY" value="-5" />
Determine the location of the label in the X and Y directions.

Image
45

 

<add key="NameGripprofileAboveOpening_00" value="Dummy" />
Define the name of any gripprofile above a window and/or door opening. The grip profile is then sized relative to the top of the recess.

 

<add key="RankingDimLines" value=" />
Define the order of the dimension lines to be placed.

There are 8 groups to define:
1. Steel
2. Steel grouped
3. Concrete
4. Concrete grouped
5. Miscellaneous
6. Miscellaneous grouped
7. Openings, indentations and recesses
8. Overall dimensions

 

Grouped dimension lines are dimension lines on which there are multiple items (subassemblies), as defined by the "PrefixForGrouping-Parts" parameter(s).

The order of the dimension lines is determined by the order of the numbers.
The first defined group is placed closest to the concrete contour. The default order is: "1;2;3;4;5;6;7;8". If you want to define a different order, it is sufficient to fill in only the changes compared to the standard.
For example, if you want to measure the miscellaneous materials first, then the openings and recesses, and then the rest then enter: value="5;7". (behind the screens the list will be completed with the not yet defined default values: value="5;7;1;2;3;4;6;8")

 

<add key="PrefixForGroupingParts_00" value="E" />
Normally, each unique assembly/subassembly is sized on a separate dimension line. It is also possible to filter by the prefix of the subassembly.
Determine the assembly prefix of parts to be placed on one dimension line. This parameter can be copied as desired, then let the number of the name always increase by 1: "PrefixForGroupingParts_01", etc.

Image
46

In addition, it is possible to filter by multiple prefixes. In that case place
a ";" between the different values after value=. For example: <add key="PrefixForGroupingParts_00" value="E;A" />
All subassemblies with assembly prefix "E" and "A" are now placed on one size line.

Image
47

 

<add key="DimLineSetting_00" value="Lifting anchor;green" />
Filtering by name can be done on the name of both main components and items and a saved dimension line attribute setting can be associated with that. After "value=" define the name to be filtered on, and after the ";" the dimension line setting.

The "DimLineSetting" parameters can be copied. Always let the numbers increase by 1; DimLineSetting_01, etc.

Image
48

 

Example: green dimension lines for anchors and red total dimensions

Image
49

 

<add key="DrawSkewedDimlines" value="True" />
Set to "True" to allow slanted surfaces to be sized.

Image
50

 

<add key="DrawSkewedDimlinesLimit" value="300" />
Minimum length of the skew.

Image
51

 

<add key="SkewedOffsetRange" value="100" />
Offset value for dimension embeds along the skewed plane. If a precast unit falls within this Offset Value, then that part is measured.

Example:  with green dimension lines for anchors and the red total dimensions

Image
52

 

<add key="StartDistanceSkewedDimensionLine" value="12" />
Distance between the first skewed dimension line and the skewed plane.

 

<add key="StepDistanceSkewedDimensionLine" value="6" />
Spacing between the slanted dimension lines.

 

<add key="DimWeldedParts_00" value="STEK" />
It is possible to place dimension lines at parts that are a welded part of a subassembly
This line can be optionally copied through with an increasing sequence number.

Example: From a subassembly consisting of several parts, only dimension lines should be placed at the welded cuttings (with name = STEK)

Image
55

 

<add key="UseSelectionfilterInsteadOfName" value="False" />
If this parameter is set to "True" then the filtering is no longer done on the name of parts but the model selection filter is used. This applies to all parameters where a name is required. The existing Tekla Structures filter functionality can then be used and one can start filtering by class, material quality, etc., as desired.
Example:

<add key="UseSelectionfilterInsteadOfName" value="True" />
in combination with
<add key="DimTwoRef_00" value="class_13" />

 

Image
56

 

 

DimConcreteView2

Application: This definer tool is identical to the above tool DimConcreteView and is therefore used in the same way but with different settings in the configuration file standard.csoft.d.dimconcreteview2.
This tool can be used, for example, if you make several sheets of one element (e.g. one for production and one for third-party inspection) with a different way of measuring. You could also use this tool to size another window.

For example, for a beam, you can use tool DimConcreteView for the Front view and tool DimConcreteView2 for the Top view. In that case, change the name of the window to be sized in the configuration file.
 

Config file: standard.csoft.d.dimconcreteview2.

 

SetAbsDim

Application: Adjusting the measuring zero point for all measuring systems. By default, the zero point of absolute dimension lines is in the upper left corner of a part. In the length direction of the part, this direction can be adjusted by means of a variable in Tekla Structures. In height, this is not possible in Tekla Structures. This tool changes all absolute dimension lines in the named window (default "Front view").
This tool changes the dimension datum to the bottom of the part for all absolute dimension lines present in the named window (default "Front view").

 

Example:

Image
57

 

 

 

GridDim

Application: Enlarging the view area of a window (default "Front View") to make frames lying outside the element visible and to measure vertically and horizontally the element's vertices to the frames.
The Tool enlarges the visibility area of the window and then measures the element's vertices to the found grids.

 

Example: 

Before running the tool:

Image
58

 

After running the tool:

Image
59

 

Config file: standard.csoft.d.griddim

 

Parameters: 


<add key="MinFreeSpaceToGrid" value="500" />
Define the distance by which to search for a grid line. If the grid line is further away than the specified value then the visibility area is not increased.

 

<add key="MinFreeSpaceToGridHor" value="500" />
Same as previous parameter but for horizontal grid lines.

 

<add key="DistanceDimLineGrid" value="12" />
Determine the horizontal space (distance below) with regard to the concrete contour where the dimension line is to be placed.

 

<add key="HorDistanceVertDimLineGrid" value="12" />
Determine the vertical space (distance left) from the concrete contour where the dimension line should be placed.

SymFoundationPiles

Application: The placement of symbols on foundation piles on survey drawings.
Determine in the configuration file which symbol should be placed at which pile size.
 

Config file: standard.csoft.d.symfoundationpiles

 

Parameters:

 

<add key="Profile_00" value="250*250" />
<add key="Symbol_00" value="FoundationPiles@1" />
Behind "Profile_00" define the profile size and behind "Symbol_00" the symbol to be placed with that profile (name symbol file@number)

Always copy the above 2 lines from the configuration file to assign multiple symbols to different pole sizes. Always let the numbers after "Profile_" and "Symbol_" increase by one. ("Profile_01","Symbol_01"

 

Image
60

The view scale and the dimensions of the pole determine the size of the symbol. The standard symbol file (standard.sbl) determines the color of the symbols to be placed (and any offset of the symbol from the center point).
The placed symbols are associated with the foundation piles. If a pile is moved in the model then the symbol is moved with the update of the drawing. If piles change or new piles are added in the model then the tool has to be executed again.
 

Filter by foundation pile name: To avoid that any parts visible on the drawing (e.g. columns D300 on the first floor) are also assigned a symbol you can filter on the name of the foundation piles. Multiple names can be separated by a semicolon "; ".
<add key="NameOfFoundationpiles" value="Foundation pile;Borehole pile" />

 

Filter by view name: Define the name of the view in which the SymFoundationPiles tool should place pile symbols. This is in situations where there are multiple views in one drawing and only a certain window needs to have symbols placed in it.

 

<add key="NameOfView" value="Pile Plan" />
Separate multiple windows with a semicolon ";",
Use a Joker/Asterisk "*" to define all views.

 

Pile symbols depending on assembly number:  symbols can now also be defined on the assembly number of the pile. For foundation piles that are numbered with the Tekla Structures number command (PCD and FUD licenses) the parameter below must be set to "2".

<add key="MethodOfSymbolPlacement" value="2" />

A symbol should be defined for each assembly number occurring in the model.
defined.

 

<add key="CAST_UNIT_POS_00" value="P1" />
<add key="CUSymbol_00" value="FoundationPiles@1" />

Optionally, the above parameters can be copied with an
increasing sequence number for CAST_UNIT_POS_XX and CUSymbol_XX.

 

Pile symbols depending on Engineering assembly number:  If numbering is done with Engineering licenses then the Symbol Placement method "3" define.

<add key="MethodOfSymbolPlacement" value="3" />
Defining which symbol on which mark number should be placed done with the parameters:
<add key="DESIGN_GROUP_MARK_00" value="P1" />
<add key="DGMSymbol_00" value="FoundationPiles@1" />

 

Pile symbols depending on selection filters: To assign symbols to any other filter method, for example the load to be recorded or user attributes with head reinforcement information, model selection filters can be used. In that case, choose Symbol Placement Method "4" and use the parameters below to assign the symbols.
<add key="MethodOfSymbolPlacement" value="4" />
<add key="SelectionFilter_00" value="Filter1" />
<add key="SFSymbol_00" value="FoundationPiles@1" />

 

Pile symbol for undefined piles: If a foundation pile is not defined (with dimension or assembly number, depending on the defined method) then a symbol can be added to those piles with parameter:
<add key="SymbolForUndefinedPiles" value="foundationpiles@255" />

LoadViewSettings

Application: This tool allows you to load existing view settings and apply them to named Views.
 

Config file: standard.csoft.d.loadviewsetting.

 

Parameters: 


<add key="NameOfView_00" value="Topview" />
Define the view name in which the tool should be executed.

 

<add key="AttributeFileView_00" value="perspective" />
Define the View setting.

 

Image
70


 

Tip: In the saved view settings, set the location of the views to "fixed" to prevent views from changing location on the drawing.

With parameter <add key="KeepScaleValue_00" value="True" /> you determine whether the scale of the window should be kept (value="True") or that the scale of the saved view should be applied.
(value="False")

The parameters Name of View, AttributeFileView and KeepScaleValue can be copied into the desired in the configuration file standard.csoft.d.loadviewsetting.
Then use follow-up numbers.

<add key="NameOfView_00" value="TopView" />
<add key="AttributeFileView_00" value="HiddenLinesOut" />
<add key="KeepScaleValue_00" value="True" />
<add key="NameOfView_01" value="Front View" />
<add key="AttributeFileView_01" value="Weld Label" />
<add key="KeepScaleValue_01" value="True" />

Some practical examples for using this tool:
- Not showing items in Top view CU drawings
- Weld label in certain views on W drawings
- Showing exact sections of steel sections (with radius) in all sections on overview drawings (use constant "Sections" for NameOfView)
- Showing/not showing part and/or bolt labels in a certain view.
 


 

 

CurvedDimlines

Application: This tool allows you to place one or more curved dimension lines on main parts. A number of total dimensions to be specified are placed along a reference line to be defined reference line. Any welded-on parts or parts added as subassemblies can then be added manually to the reference line with the dimension line with the command create dimension point. This tool works on W, A, and CU drawings.

Config file:standard.csoft.d.curveddilmlines

 

Parameters: 


<add key="NameOfFrontView" value="Top View" />
Define the view name in which to execute the tool.

 

<add key="NumberReferenceLineOuter" value="4" />
<add key="NumberReferenceLineCenter" value="0" />
<add key="NumberReferenceLineInner" value="2" />
Define how many curved dimension lines are to be placed. You can measure along the outside of the bent part (Outer), along the center line (Center) or along the inside (Inner)
 

Image
62

2 curved lines on the centerline of a steel girder

 

Image
63

3 curved dimension lines along the outerline and 2 dimension lines along the innerline

 

<add key="DimLineSetting" value="standard" />
Define the dimension line attribute file (saved dimension line setting) of the curved dimension line

 

<add key="StartDistanceVerticalDimensionLineLeft" value="12" />
Define the starting distance from the part to be dimensioned to the first dimension line.

 

<add key="StepDistanceHorizontalDimensionLine" value="7" />
Define the intermediate distances between the curved dimension lines to be placed.

DepositMarks

Application: This tool can be used to remove labels from precast units that are located in or around the outer contour of an element and replace them with a text label, outside the element and perpendicular to the system points of the precast unit.
To be able to replace the labels, they have to be on the drawing in the first place. No text labels can be placed on parts where - before the tool was executed - no labels were placed.

Image
64

 

Parameters:


 <add key="NameOfView" value="Front View" />
Name of the View in which the tool is to be executed

 

<add key="OffsetRange" value="200" />
Define an offset along the outer contour of the element. If a dimension embed outside this range then the label is not replaced for a text label.

Image
65

 

<add key="MarkBorderDistance" value="40" />
Define the distance from the outline to the location of the text label.

Image
66

 

 

<add key="AttributeSettingLabel" value="label" />
Define a saved attribute setting for the text label display.

 

Image
67

 

<add key="DeleteMarks" value="False" />
Option to not delete the labels present. Useful to set this value to "False" while defining the other parameters. If the desired settings are good then set this value to "True".

 

 

Wizard

Application: Applying multiple Drawing Definer settings to multiple drawings and/or multiple views.

 

Config file: standard.csoft.d.wizard

 

With this tool several configuration files from different tools can be applied to a given drawing. It is also possible to run a tool 2x (or more) on the same drawing (with 2 different configuration files in which a different view is defined).

The tool Wizard can only be executed on All drawings or on Selected drawings in the list of drawings.

When the tool Wizard is executed all other tools are disabled.
The tool filters on the name of the drawing. One or more configuration files can then be linked to this drawing name. Separate multiple configuration files with a semicolon ";"

Parameters:
<add key="NameOfDrawing_00" value="WAND" />
<add key="Configuration_00" value="standard.csoft.d.dimcog ; wall.csoft.d.dimconcreteview" />
In the above example, the "standard" configuration of the DimCOG tool and the "wall" configuration of the DimConcreteView tool is executed on drawings named "WAND"

The above 2 parameters can be copied through and given an incremental sequence number.

An example configuration file for measuring several different types of drawings at once and providing them with symbols etc. could look like this:

Image
68
Image
69

 

When applying multiple configuration files to a drawing, the defined order is also the order to execute. (so, for example, not first "x.csoft.d.griddim" and then "y.csoft.d.dimconcreteview" because the latter will then remove the dimension lines of the former).

 

Updating configuration files during an update

If you are going to update to a new version of the Drawing Definer then custom configuration files need to be updated with newly added parameters. (Otherwise the new applications will not work)
The easiest way is to run the tools in an empty test model so that in the attributes folder of that model the default configuration files will be created.
Then add (cut and paste) the new parameters to your existing configuration files using the Release Notes.
Note: if configuration files are read from the server because they are also visible in new models. Please move these files temporarily. 


All rights reserved. No conclusions can be associated to the representation of the pictures in relation to the operating systems under which Tekla Structures runs.
 
This work is licensed under the Creative Commons Attribution-NonCommercial-NoDerivatives 4.0 International License. To view a copy of this license, visit http://creativecommons.org/licenses/by-nc-nd/4.0/ or send a letter to Creative Commons, 444 Castro Street, Suite 900, Mountain View, California, 94041, USA.

Indienen