Exported bolt XML data

Modified: 16 Jan 2026 Tekla Structures 2026
2026
Tekla Structures

Default data included in XML file

Data Description Example Data
PartId Globally Unique Identifier (GUID) of the bolt group. <PartId>1cd0dbe6-bc01-4dd4-a47d-4a78c4766642</PartId>
PartMark* This will always be blank because bolts in Tekla Structures do not have part marks. <PartMark />
MainMember* This will always be false because bolts in Tekla Structures are always attached to a member and never the main member. <MainMember>false</MainMember>
PartQuantity Number of bolts in the bolt group. <PartQuantity>3</PartQuantity>
Shape The default values for shape are HS, MB, NU, WA, or STD. * <Shape>HS</Shape>
Dimensions The diameter and length of the bolt as defined in the Bolt catalog properties. <Dimensions Metric="0">HS 0.75" x 2.5"</Dimensions>
Grade

For Bolts (HS or MB), the grade is defined by the Standard set in Bolt assembly catalog properties.*

For Nuts, washers, and Studs, the grade is defined by the Standard set in the Bolt catalog properties.*

<Grade>F1852</Grade>
Length** The length value will not be populated as it is provided in the Dimensions. <Length UOM="in"></Length>
Remark Will report Field or Shop based on bolt group the Bolt type property. <Remark>Field</Remark>

* The SHAPE and GRADE data may be overridden by the hard-coded translations. See section "Hard-coded translations" below.

** These fields are sections that are required for parts, but are not applicable to bolts. Because the format for bolts is the same, the values will be empty.

Shape

The default values for SHAPE are HS, MB, NU, WA, or STD depending on the type specified in the Bolt Catalog.

You can manually override the individual bolt group bolt SHAPE by specifying a user-defined value for the bolt shape. It is not possible to manually override the nut or washer SHAPE values.

Grade (Material)

Bolt assembly GRADE data is output differently depending on the component of the assembly. Bolts obtain the GRADE data based on the Standard value for the assembly in the Bolt Assembly Catalog.

All other bolt assembly elements obtain the GRADE data based on the Standard value for the assembly in the Bolt Catalog.

Hard-coded translations

When Export to Tekla PowerFab compiles the XML file data, there are a few hard-coded translations that are performed. These can affect both the <SHAPE> and <GRADE> data that is exported.

Note:

The translations are not applied when you specify a user-defined bolt shape.

Anytime a Grade contains the text "TC", then the shape is set to "HS":

<SHAPE>HS</SHAPE>

If the bolt Grade contains "TC" and "A325", then the grade is set to "A325TC":

<GRADE>A325TC</GRADE>

If the bolt Grade contains "TC" and "A490", then the grade is set to "A490TC":

<GRADE>A490TC</GRADE>

If the bolt Grade does not contain "TC", but does contain "A325, "A490", "F1852", "F2280", or "F3148", then the shape is "HS", and the grade is left as-is:

<SHAPE>HS</SHAPE>

If the bolt Grade does not contain "TC" and is not any of those grades, then the shape is set to "MB":

<SHAPE>MB</SHAPE>

Example XML data for bolt assembly

<AssemblyPart>
      <PartId>1cd0dbe6-bc01-4dd4-a47d-4a78c4766642</PartId>
      <PartMark />
      <MainMember>false</MainMember>
      <PartQuantity>1</PartQuantity>
      <Shape>HS</Shape>
      <Dimensions Metric="0">HS 0.75" x 1.5"</Dimensions>
      <Grade>A325TC</Grade>
      <Length UOM="in"></Length>
      <Remark>Field</Remark>
</AssemblyPart>
<AssemblyPart>
      <PartId>1cd0dbe6-bc01-4dd4-a47d-4a78c4766642</PartId>
      <PartMark />
      <MainMember>false</MainMember>
      <PartQuantity>1</PartQuantity>
      <Shape>NU</Shape>
      <Dimensions Metric="0">NU 0.75"</Dimensions>
      <Grade>HEAVY_HEX</Grade>
      <Length UOM="in"></Length>
      <Remark>Field</Remark>
</AssemblyPart>
<AssemblyPart>
      <PartId>1cd0dbe6-bc01-4dd4-a47d-4a78c4766642</PartId>
      <PartMark />
      <MainMember>false</MainMember>
      <PartQuantity>1</PartQuantity>
      <Shape>WA</Shape>
      <Dimensions Metric="0">WA 0.75"</Dimensions>
      <Grade>PLAIN</Grade>
      <Length UOM="in"></Length>
      <Remark>Field</Remark>
</AssemblyPart>

See also

Bolt catalog properties

Bolt assembly catalog properties

How the bolt catalog and bolt assembly catalogs work together

Add, modify, and delete drawings

Submit