Skip to main content

Troubleshooting Connector problems

Tekla Structures - Not version-specific Trimble Connect Web - Windows
Windows
Trimble Connect
Web
Trimble Connect
Not version-specific
Tekla Structures

This is a troubleshooting guide for Connector problems between Trimble Connect and Tekla Structures, for example for the following situations:

  • Overlay models do not display successfully.
  • The Trimble Connector - Models dialog box does not appear when clicking the Models button on the Trimble Connect ribbon tab.
  • Error message: "An error has occurred while updating the model in Tekla Structures."
  • Error message: "Trimble Connector: Failed to refresh folders."
  • Error message: "System.MissingMethodException: Method not found: 'System.Threading.Tasks.Task`1<System.Collections.Generic.IEnumerable`1<Trimble.Connect.Client.Models.Person>> Trimble.Connect.Client.IProjectMembersController.GetAllAsync(System.Threading.CancellationToken)'."

Steps to resolve

Update 23.3.2026: Known issue with folder visibility in Trimble Connector

We have received reports regarding inconsistent visibility of overlay models and folder hierarchies within the Trimble Connector in Tekla Structures 2024 version.

  • The Trimble Connector fails to display the full folder hierarchy or specific subfolders from the linked Trimble Connect project.
  • User permissions appear correct in Trimble Connect Web.
  • All files and folders remain correctly visible in the Trimble Connect Web.
  • The issue is project-specific and does not affect all users or all projects.
  • Deleting the local data as advised below may temporarily restore visibility, but the issue may recur after restarting Tekla Structures.

This behavior is related to backend updates and automatic migration performed since mid December 2025 regarding the Trimble Connect permissions inheritance. 

Trimble Connect Desktop also had the same issue, but it was fixed in version TCD-V1.27.1.

A fix for this Connector issue is included in the Tekla Structures 2024 Service Pack 12.1: Release Notes

 

Known issue with project users without admin rights

There is a known issue in Tekla Structures 2024 SP6 and SP7 where users without full project admin rights in the Trimble Connect project encounter errors when attempting to refresh Connector models for the second time. The error messages in the log may include "Failed to refresh folders" and "Method not found".

-> This is fixed in Tekla Structures 2024 SP8 version (TTSD-68654)

 

Reboot your computer

  1. Check the Windows Task Manager if processes like `TrimbleConnector`, `IFCWorkerLoader`, or `ImportLoader` are hanging.
  2. Reboot your computer to get rid of hanging processes.
  3. Note that large and complex IFC projects may take time to convert to trb format. 

 

Close other Tekla Structures sessions

Make sure you don't have multiple Tekla Structures sessions running at the same time as the Trimble Connector works only with the first Tekla Structures session that is started.

 

Rename the local folder

If Trimble Connector - Models dialog box is not appearing for certain model, it might help to delete and recreate the local data:

  1.  Close Tekla Structures.
  2. In the model folder, rename the `Local` folder located at `\Datastorage\Local` to "delete it".
  3. A new Local folder will be created automatically when you restart Tekla Structures and open the model and try opening Connector.

 

Check for installation issues

  1. Error messages such as "System.MissingMethodException: Method not found" may indicate a broken installation, possibly due to missing or mismatching service packs.
  2. First try repairing the Tekla Structures installation and rebooting the computer.
  3. If the previous step did not help, perform a complete uninstallation and reinstallation of Tekla Structures to resolve this. 

 

Workaround for local project data

  1.  Close Tekla Structures.
  2. Delete the local project data at `C:\Users\<user>\AppData\Local\Trimble\Tekla Structures\Trimble Connector\<version>\<unique_code>\<project_folder>`.
  3. Restart Tekla Structures and open the model.
  4. Exclude the project from collaboration: File > Trimble Connect > Exclude from collaboration..
  5. Start collaboration again: File > Trimble Connect > Start collaboration.

These steps should help address some issues with the Trimble Connector.

 

See also

Troubleshooting Trimble Connect interoperability problems with Tekla Structures

Submit

Table of Contents