BW Eaves Beam to Stanchion (132) - Parameters tab
Not version-specific
Tekla Structures
Environment
Not environment-specific
Use the Parameters tab in the BW Industries' Eaves Beam to Stanchion Properties panel to control how the connecting members are defined within Tekla Structures.
Image
| Option | Description | Default | Other |
|---|---|---|---|
| Eaves Cleat is (Welded, Bolted) | This specifies whether the eaves beam cleat should be welded to the stanchion or bolted. If the bolted option is chosen then a plate will be added to the fixing bracket in order to allow a bolted connection to the stanchion. Otherwise the fixing bracket will be welded directly to the stanchion. | The default is set to Welded. | |
| Edge Gap Two secondaries | If two eaves beams are selected in the application of the joint then this value specifies the edge distance that should be maintained between the end of the eaves beams and the centre of the fixing bracket. | The default setting cuts each eaves beam back 3mm from the center line. |
Image
Image
|
| Free Dist Eaves Beam to Cleat | This allows extra clearance to be applied between the fixing bracket and the eaves beams in the joint. This will be applied in addition to the default clearance. If no value is specified then no extra clearance will be applied. | The default setting is 0. |
Image
|
| Chamfer | Currently this has no effect. | ||
| Overhang dimension | This specifies the overhang dimension for a gable end only. The dimension is measured from the centre of the cleat. | The default setting is 0. |
See also
BW cold rolled - Important informationBW Eaves Beam to Stanchion (132)
BW Eaves Beam to Stanchion (132) - Parts tab
BW Eaves Beam to Stanchion (132) - Bolts tab