Use the Parameters tab in the CMF Eaves Brace Properties panel to control how the connecting members are defined within Tekla Structures.

Image
tekla-structures-cmf-54-parameters-tab.png

 

OptionDescriptionDefaultOther
Top or Bottom
(Top, Bottom)
This defines whether the eaves brace attaches to the top or bottom hole on the purlin.The default is set to Bottom. 
General Bolt GradeThis sets the standard for all bolts added by the macro excluding those which may be placed to the web of the eaves beam. The default setting is 8.8XOX.  
Eaves Beam Web Bolt GradeThis sets the standard for bolts placed to the web of the eaves beam. If this standard specifies countersunk bolts then a suitable packing plate will be added. The default setting is 8.8XOX. 
Connection type
(Standard, Under Purlin) 
This is a simple field to indicate whether to use a standard eaves brace or an under eaves brace connection.The default is set to Standard. 
Under Purlin Type
(Standard, Non Standard)
The Standard option will use standard angle sizes for connecting to the back of the purlin. The Non Standard will calculate an appropriately sized cleat angle.The default is set to Standard. 
GroupThis sets the class that all parts will be included in.The default setting is 99. 