Skip to main content

Kingspan Horizontal Cladding Sleeve (120) - Parameters tab

Tekla Structures - Not version-specific
Not version-specific
Tekla Structures
Environment
Not environment-specific

Use the Parameters tab in the Kingspan Horizontal Cladding Sleeve Properties panel to control how the sleeve is defined within Tekla Structures.

Image
tekla-structures-ks-120-parameters-tab.png

 

OptionDescriptionDefaultOther
Cleat Thickness (Not Set, 8, 10, 12) This specifies the thickness of the cleat and MUST be defined.The default is set to Not Set. 
Sleeve (Default, None, Sleeve)This allows the user to select if the connection has a sleeve or not. A sleeve can be selected to allow for future extensions at gable ends. The default option is a standard sleeve for two purlins of the same thickness. The default is set to Default. 
Force Sleeve Holes
(No, Yes)
This allows the user to force holes to be placed in the purlins corresponding to the sleeve hole positions when there is no sleeve. This will be done only if this option is set to Yes, otherwise when set to No these holes will be omitted.The default is set to No. 
Sleeve Assembly PrefixThis sets the assembly prefix for the sleeve defined in the joint.The default is set to SA. 
Sleeve Assembly Start NumberThis sets the assembly start number for the sleeve defined in the joint.The default setting is 1. 
Overhang dim. Gables onlyThis specifies the overhang dimension for a gable end only. The dimension is measured from the centre of the cleat.Where a sleeve is defined the purlin will be cut back to the standard manufacturer's end gap and the sleeve will be positioned to the overhang. Otherwise the purlin will be extended to the overhang point.
Image
tekla-structures-parameters-tab-overhang-dim-gables-only-02.png
Cleats are (Bolted, Welded, Workshop Bolts)This specifies whether the cleat is welded or bolted to the rafter. If the cleat profile is not explicitly given in the parts dialogue the standard profile will be used from the data files.The default is set to Welded. 
Bolt-on Cleat CentreThis centres between the two bolts in the bolt on plate in mm. If centres is zero one bolt will be placed in the plate.This value will come from the data files.
Image
tekla-structures-parameters-tab-bolt-on-cleat-backmark.png
Bolt-on Cleat BackmarkThis sets the distance from the front of the cleat in mm.This value will come from the data files.See above.
Cleat Finish
(Default, Black, Galvanised, Powder coated) 
This specifies the finish of the cleat. If set to Default the cleat finish will be black.The default is set to Default. 
Stays on (None, Both, Right, Left)This allows the user to define whether they want rafter stays or not, and to place them on only one side of the rafter/stanchion if required. You may wish to include both rafter stays at an overhang in order to allow for future extensions. Left and right are specified from the cleat side as shown in image.The default is set to None, rafter stays are turned off.
Image
tekla-structures-parameters-tab-stays-on-02.png
Stay Section
(Default, RNA, RNB)
This specifies which of the two stay sections to use. If set to Default the value will come from the data files.The default is set to Default. 
Stays Horiz DimensionThis sets the position of the stay bolt along the purlin, measured from the centre of the cleat. The default position is included in the data files and may be the same as a hole used for another purpose (e.g. sleeve). However, if a value is entered here, then completely separate bolt will be defined even if it coincides with another hole. 
Stay Plate Horiz Bolt PosThis sets the position of the bolt from the edge of the stay plate or cleat.This value will come from the data files.
Image
tekla-structures-parameters-tab-stay-plate-horiz-bolt-pos.png
Stay Plate Vertical Bolt PosThis sets the position of the bolt from the end of the stay plate or cleat.This value will come from the data files.
Image
tekla-structures-parameters-tab-stay-plate-vert-bolt-pos.png
Stay Plate Chamfer DimensionThis specifies the chamfer that should be applied to the stay plates defined by the joint.The default is based on the internal radius of the profile. However, if a value is entered here, then the chamfer can be increased. 
Stay to (Haunch, Rafter)
This determines where the stays should be positioned if the joint is applied above a haunch. If this is set to haunch the stays will be attached to the haunch otherwise they will be positioned to go to the rafter.
WARNING (see images): If the stay is applied to the haunch and the haunch profile is subsequently modified the stays position will not be re-calculated. This can be resolved by modifying the cold rolled sleeved joint using it’s existing parameters.
NOTE: The haunch must be part of the system haunch connection typically using components 40 or 102.
The default is set to Haunch.
Image
tekla-structures-parameters-tab-stay-to-haunch-modify-before.png
Before
Image
tekla-structures-parameters-tab-stay-to-haunch-modify-after.png
After
Standard Bolts to PurlinThis defines the standard of all bolts that pass through the purlins in the joint. Available standards are defined in the bolt assembly database. This standard also applies to all bolts to the rafter providing the standard of these bolts is not explicitly set by the following parameter and to the bottom stay bolts if a bolt standard is not specified in the stay data file.The default setting is 8.8XOX. 
Standard Bolts to RafterThis defines the standard of all bolts that pass through the rafter in the joint. Available standards are defined in the bolt assembly database.The default setting is 8.8XOX. 

See also

Kingspan cold rolled - Important information
Kingspan Horizontal Cladding Sleeve (120)
Kingspan Horizontal Cladding Sleeve (120) - Parts tab
Submit