The PEB Splice plugin allows you to create a splice plate connection between two PEB Members. It can be used as

  1. Splice connection between two PEB Member Columns
  2. Splice connection between two PEB Member Rafters
  3. Ridge connection between two PEB Member Rafters at ridge

How to locate

Installers are available at Pre-Engineered Building Tools for Tekla Structures version 21.0 and above.
For older versions, download at Pre-Engineered Building Tools old installers

After installation, the PEB Splice plugin is available in the Applications & Components.
 
Image
image.png

Usage

Click PEB Splice in the Applications & Components. Select two PEB members as input. The component should be a PEB Member.
 
Note:
  • Always use PEB members as rafters/columns.
  • Use only component selection and not part selection.
  • Do not make the first outer flange width/thickness of the PEB member zero.

PEB Splice dialog box

The dialog box has the following tabs:
  • Picture
  • Bolts
  • Parts
  • Stiffeners
  • Special Stiffeners

Picture

     
Image
image.png

1. Offset options

 
Image
2015_09_01_05_37_256.png
The rafter/column work points are at the same point. After applying the connection and modifying the PEB member end/start, offset is adjusted according to the plate thickness. This is the default.
 
Image
2015_09_01_05_37_337.png
In this option, you maintain the end offset in PEB Member equivalent to plate thickness.

2. End condition

Maintain design depth option is useful mainly in the ridge connection type. It will maintain the end depth applied in the PEB Member even after applying the connection.
Normal cutting at endIt is just a tapered cut at the end.

3. End plate length options

Both side projectionProjection at both sides from web line.
Total length and projectionProjection from the outer flange side web line and the otal length of the plate.

4. Erection gap

Image
image.png
No erection gap
Image
image.png
Equal gap
Image
image.png
Gap for primary
Image
image.png
Gap for secondary
 

Bolts

User field 8 is for updating any additional information on bolts. The value is shown in bolt UDA in Bolt User Field 8.
  
Image
2015_09_01_05_56_578.png

Below an example of bolt arrangement:
 
Image
2015_08_19_05_42_153.png

 
Image
2015_08_19_05_43_334.png

    
Image
2015_09_01_06_00_179.png

Parts

End plate parameters can be changed from this tab. If plate profile name is default, it reads from Menu>Settings>Options>Components>ProfileNames>Plate. The same profile name is applicable for stiiffeners also.

 
Image
image.png


Stiffeners

See PEB Base Plate help.

Special stiffeners

  
Image
2015_09_01_06_07_2510.png

1. Special stiffener options

 
Image
2015_09_01_06_09_4911.png
No special stiffener
 
Image
2015_09_01_06_09_5712.png
Doubler stiffener

2. Doubler flange stiffener length options

  
Image
2015_09_01_06_13_1219.png
Flange doubler stiffener flush with end plate
  
Image
2015_09_01_06_13_3020.png
Flange doubler length input option
 
Image
2015_09_01_06_10_5615.png
Flange doubler projection from flange input option

3. Doubler stiffener types:

 
Image
2015_09_01_06_11_3816.png
Rectangle 
 
Image
2015_09_01_06_11_5417.png
Rectangle with chamfer
 
Image
2015_09_01_06_12_0318.png
Trapezoid

Additional information

(1) Update the PEB Member after applying the connection to update the changes due to the connection at the end.
(2) Make sure that the end points of both members are the same at the connection plane.
 
Image
2015_08_19_06_11_3710.png



 
Absenden