Direkt zum Inhalt

Metsec Apex Ties (30) - Parameters tab

Tekla Structures - Not version-specific
Not version-specific
Tekla Structures
Environment
Not environment-specific

Use the Parameters tab in the Metsec Apex Ties Properties panel to control how the connecting members are defined within Tekla Structures.

Image
tekla-structures-metsec-30-parameters-tab.png

 

OptionDescriptionDefaultOther
Type of Apex Tie
(Default, Angle Apex Tie)
This specifies the type of apex tie to be used by the macro. If set to Default it will apply round loks for purlins of all section depths excluding 302 & 342 where apex tie angles will be used. If set to Angle Apex Tie it will force an apex tie angle to be used for all section series.The default is set to Default. 
Apex Tie to Back
(Default, No, Yes)
If the strut position interferes with the bolts then this control can be used to set the position of the strut relative to the cleat. If set to Default option the strut is put to the inside of the cleats.The default is set to Default.
Image
tekla-structures-parameters-tab-eaves-brace-to-back-no.png
No
Image
tekla-structures-parameters-tab-eaves-brace-to-back-yes.png
Yes
Face Strut to the
(Left, Right)
This controls the direction of the apex tie created. If this is set to Left then looking from the first purlin selected to the second, the apex tie will be orientated so that the strut faces to the left. The Right option similarly causes the apex tie to face to the right.The default is set to Left.
Image
tekla-structures-parameters-tab-face-strut-to-the-left.png
Left
Image
tekla-structures-parameters-tab-face-strut-to-the-right.png
Right
General Bolt GradeThis sets the standard for all bolts added by the macro excluding those which may be placed to the web of the eaves beam. The default setting is 8.8XOX. 
GroupThis sets the class that all parts will be included in.The default setting is 99. 
Position of Apex Tie
(Bottom, Top, Default)

This specifies which holes on the purlin to attach the apex tie. If set to Default the apex ties will be positioned to the top hole.
The default is set to Default. 

See also

Metsec cold rolled - Important information
Metsec Apex Ties (30)
Metsec Apex Ties (30) - Parts tab
Absenden