A simple flat slab model, as shown below, is used to demonstrate the techniques involved in the slab design process.
Note that a transfer level is present at the first floor:
Set up pattern loading
If necessary, you should consider manually splitting and joining slab panels to facilitate the management of the pattern loading process.
By default, only beam loads and slab loads that have been decomposed onto beams are patterned. Loads applied to slabs should be manually patterned using engineering judgment. This is achieved on a per-panel basis for each pattern load by toggling the loading status via Update Patterns on the Load ribbon.
For further details, see: Create and manage load patterns.
Configure slab mesh for FE Chasedown analysis
Unless an override is applied, the FE mesh at every level will be generated from the mesh parameters defined in the Structure Properties.
By using the triangular mesh type with default mesh size and uniformity, the initial mesh at roof level would be similar to that shown below.

While the above mesh is sufficient, if your intention is to review/extract localized results (e.g. shear on perimeters near to the columns and walls) a refined mesh should be considered. You might choose to use such a refined mesh at the transfer level for example if you are intending to apply the checks suggested by the IStructE guide, "Design of transfer slabs", or you have some other specific reason to do so.
You can define a different mesh at a specific level of interest (such as a transfer level) by specifying an override as follows:
-
In the Structure tree, expand the
Sub Models branch. - Select the sub model that includes the level to be overridden.
-
In the Properties window, select the Override model's option and then adjust the mesh size and uniformity factor to generate a tighter mesh according to your needs.

Enable slab meshing for the transfer level in 3D analysis
To ensure accurate load distribution and model efficiency, apply the Mesh slabs in 3D analysis setting selectively for each level:
-
Transfer Levels: Enable the Mesh slabs in 3D analysis setting to accurately capture out-of-plane stiffness and load paths from discontinuous columns.

-
Typical Levels: Disable the Mesh slabs in 3D analysis setting to prevent unintended frame action and allow standard FE Chasedown routines to design the flat slabs locally.
When creating your own models, avoid enabling 3D slab meshing at every level. Enabling this setting will drastically increase your model's calculation time and cause standard flat slabs to incorrectly absorb gravity loads via frame action.
Establish slab design moments
Analysis is required to establish the moments to be used in the slab design. This analysis is automatically performed when either Analyze All, Design Concrete, or Design All are run.
At typical levels, these moments are taken from the FE chasedown model results. As each floor is analyzed individually, this method mimics the traditional design approach.
At the transfer floor level, where the Mesh slabs in 3D analysis setting has been selected, the 3D Analysis model results also will be considered.
The FE results you see may vary slightly depending on your installed service pack and may not exactly match the documentation.
Consider simple (linear) deflection (US customary units)
Approximate slab deflections can be obtained by reviewing the 2D deflection contours for the FE Chasedown results in the Results View (typically by opening a separate Level view of each floor).
Deflection results for combinations should be viewed based on "service" rather than "strength" factors. In this way, the applied stiffness adjustments do not need to account for load factors.
For flat slab panels, deflection checks are not performed automatically. In practice, flat slab models are often irregular, so some degree of engineering judgment will be required.
If the Head Code you are working to prevents you from running a Rigorous Deflection Check, you can still use a "Deemed-to-Satisfy" method to assess deflections utilizing slab strips as outlined below:
-
With the level view displayed in 2D, click Result Strip and create a strip between supports.

-
To display the strip results, right-click the results strip and choose Open strip diagrams view. The maximum deflection and span of the strip are both reported.

In this example, there is a requirement to limit total deflection to span/240.
Taking the span as the length of the slab strip: 288 in.
Deflection limit: 281/240 = 1.2 in.
Actual deflection: 0.7 in. The check passes.
The initial check was performed by taking the diagonal across a slab panel. Checks should also be made between the horizontal and vertical spans. More generally, check the maximum deflection occurring along a straight line between any two support points.

Consider simple (linear) deflection (metric units)
Approximate slab deflections can be obtained by reviewing the 2D deflection contours for the FE Chasedown results in the Results View (typically by opening a separate Level view of each floor).
Deflection results for combinations should be viewed based on "service" rather than "strength" factors. In this way, the applied stiffness adjustments do not need to account for load factors.

For flat slab panels, deflection checks are not performed automatically. In practice, flat slab models are often irregular, so some degree of engineering judgment will be required.
If the Head Code you are working to prevents you from running a Rigorous Deflection Check, you can still use a "Deemed-to-Satisfy" method to assess deflections utilizing slab strips as outlined below:
-
With the level view displayed in 2D, click Result Strip and create a strip between supports.

-
To display the strip results, right-click the results strip and choose Open strip diagrams view. The maximum deflection and span of the strip are both reported.

In this example, there is a requirement to limit total deflection to span/250.
Taking the span as the length of the slab strip: 7211 mm.
Deflection limit: 7211/250 = 29 mm.
Actual deflection: 14.0 mm. The check passes.
The initial check was performed by taking the diagonal across a slab panel. Checks should also be made between the horizontal and vertical spans. More generally, check the maximum deflection occurring along a straight line between any two support points.

Select a level, or sub-model
In models with distinct floor levels, you should use 2D views to work on the floor design one level at a time. Occasionally, the 3D geometry of a model may make it less easy to distinguish between individual floors, in which case it may be easier to design the floors one sub-model at a time.
When working in a 2D view, use the right-click menu to design or check slabs and patches. This saves time as only the slabs and patches in the current level are considered. Running Design Slabs or Design Patches from the Design ribbon will take longer, as it considers all the slabs and patches in the model.
Add patches
This is an interactive process, requiring a certain amount of engineering judgment.
Typically, you should expect to work on this one floor at a time (making use of multiple views when creating patches as discussed below).
It is suggested that you add patches in the Results View while looking at relevant moment contours. For example, after selecting the FE chasedown result type, you might have Mx moments on in one view while simultaneously displaying My moments in a second split view, as shown below:

By doing this, it is possible to see how patches extend over the peaks.
Typically, at the initial patch creation stage, you should make the patches a reasonable size and not be concerned if they are a bit too large, as this should be reviewed and resolved at the patch design optimization stage.
In a "slab on beam" situation, you may want to add beam and wall patches to cover the full extent of non-zero top bending moments. By doing so, you can then set the top reinforcement in the slab panels to none, and the panel design should still pass.
Design panels
To design multiple slab panels, either:
- From the Design ribbon, run Design Slabs to design or check all the panels in the model. By default, newly created panels will all be in "auto-design" mode, so reinforcement is selected automatically.
or
- In the 2D view of the floor that you want to design, right-click and choose either Design plane slabs or Check plane slabs. Working in this way restricts the design or checking to the slab panels in the current view. This will be a much faster option on large buildings and avoids wasting time designing slab panels at levels where patches have not yet been set up.
- Design plane slabs will redesign slabs (potentially picking new reinforcement) regardless of the current auto-design setting.
- Check plane slabs will check the current reinforcement in slabs regardless of the current auto-design setting.
Review/optimize panel design
After running a design or check, the active view switches to a Review View to allow you to review the slab design status.
Once again, it is suggested that you use split views to examine the results.
For example you could duplicate the upper Review View, then switch the duplicate to show Slab/Foundation Reinforcement.
You could also then arrange one view above the other, as shown below.

The upper Review View shows the slab design status, and the lower Review View now shows slab reinforcement in the panels. When you make changes to the reinforcement in the lower view the status in the upper view is instantly updated.
Note that in these views the tooltip will indicate all panel/patch reinforcement as you hover over any panel.
If the selections are unacceptable, you may need to review the design settings. For example, if 8 mm diameter bars are selected and you would never use anything less than a 10 mm bar in a flat slab, then set that as a minimum.
Once the selections are reasonable, it is advisable to select all the panels and swap them out of auto-design mode (and after this point, be careful not to use the right-click option to design panels unless you truly want to).
Auto-design will select the smallest allowable bars at the minimum centers necessary to provide sufficient reinforcement area. Larger bars are only tried when the minimum permissible spacing is reached. Design options allow you to control the minimum acceptable bar sizes and spacings. It is important to use these settings so that the reinforcement established in the slabs is sufficiently spaced to allow the introduction of additional reinforcement in the patches. For example, you might set a "minimum spacing (slab auto design)" = 150 mm.
After standardizing reinforcement in the Review View, you can then run Check plane slabs from the right-click menu to check the revised reinforcement.
Remember:
- Consider swapping between Status and Ratio views. If utilizations are all < 1 but some panels are failing, then problems are related to limit checks. The Ratio view is better for helping you focus on the critical panels.
- During this process, it will also make sense to add panel patches in which the reinforcement is set to none and the strip is set to average. The purpose of this is to smooth out local peaks at the most critical locations, which would otherwise dictate the background reinforcement level needed to get a pass status.
Design patches
Having established and rationalized the slab panel reinforcement that sets the background levels of reinforcement, it is now logical to design the patches that will top up the reinforcement as necessary within the strips of each patch.
To design the patches, either:
- From the Design ribbon, run Design Patches to design or check all the patches in the model. By default, newly created patches will all be in "auto-design" mode, so reinforcement is selected automatically.
or
- In the 2D view of the floor that you want to design, right-click and choose either Design plane slab patches or Check plane slab patches. Working in this way restricts the design or checking to the patches in the current view.
-
Design plane slab patches will redesign the patches (potentially picking new reinforcement) regardless of the current auto-design setting.
-
Check plane slab patches will check the current reinforcement in the patches regardless of the current auto-design setting.

Before moving on to the next stage you might choose to swap the patches out of auto-design mode.
Review/optimize patch reinforcement
This can be done most easily by retaining the same split arrangement of Review Views, but in the Properties window for the lower slab reinforcement view, change the Entity Type from Slab Item to Slab Patch.

In the Properties window, select the surface and the reinforcement direction, and select the bars or mesh to apply. Then click on the patches in which the new reinforcement is to be applied. The aim here is to standardize the patch reinforcement. For instance, in column patches, this might include forcing the spacing of the slab reinforcement to be matched (if the slab has H12-200, then in the patch, do not add H12-125; swap to H12-200. Then there will be alternate bars at 100 crs in this strip of the patch).
Review/optimize patch sizes
At this stage, the patch sizes can also be reviewed:
- Wall patches: Can the width be adjusted (minimized)?
-
Internal column patches: Is the size reasonable? This relates to code guidance about averaging in column strips. It is not reasonable to average over too wide a width. If in doubt, the safest approach is to err on the side of caution and make them a bit smaller.
Typically the central strip within the patch will be half the patch width and the traditional expectation is that the reinforcement concentration in this strip will be approximately double the concentration in the outer strips.
-
Edge and Corner column patches: Patches can be used to capture the overall reinforcement requirement but code requirements in relation to the distribution of reinforcement need to be considered and observed. For example consider Eurocode EN-1992-1-1:2004 clause 9.4.2 where all of the transfer moment needs to be catered for in narrow effective width. ACI Code-318-25 clause 8.4.2.2 has a similar requirement but the effective width is wider and not all of the transfer moment needs to be catered for. Clearly an FE analysis exposes a peak at the column face within this strip, but significant moments exist outside the strip as shown indicatively below.

No FE analysis can contain all of the bending within some arbitrary code defined reinforcement strip width and therefore concentration of reinforcement needs to be considered during communication of design intent and the final detailing exercise. A patch that covers the entire column strip width will capture all of the transfer moment but you need to concentrate reinforcement in the code defined effective width and then make decisions about adding more reinforcement in the remaining width where FE analysis shows that the design moments will not be zero. Note that in the case of Eurocode there is also a limiting moment to consider within this effective width, refer annex I.
If the patch sizes are adjusted, you would then need to run through another cycle of slab and patch design or checking.

Add and run punching checks
Punching checks require slab reinforcement to be defined or known to determine punching capacities.

Punching checks can be added at individual locations or applied to multiple locations by windowing. For further details, see: Create punching checks
In a Structural View, you can then select any check and review the properties assigned to it. Internal, edge, or corner locations are automatically determined (with a user override if you require).
Punching check positions can also be reviewed or adjusted graphically in a Review View. This is done by selecting Show/Alter State on the Review ribbon and then selecting the Punch check position attribute in the Properties window.

For further details, see: Punch check position - review and modify.
Once the punching checks have been created, you can proceed to design or check them. For further details, see: Design and check punching shear.
After design or checking, the status is shown in the Review View whenever Slab/Mat Design Status is selected on the Review ribbon.
The potential statuses that can be displayed in the legend are:
- Pass: If no shear reinforcement is needed.
- Warning: If shear reinforcement is needed.
- Fail: If it is impossible to achieve the required capacity by adding shear reinforcement.
- Unknown: If the check has not been run yet.
- Beyond scope or error: If, for example, the centroid of the column or wall lies outside the slab.

To see the punching check status in the Review View as shown above, you might need to first switch off Slab Items and Slab Patches in Scene Content, while leaving Punching Checks selected.
Rigorous deflection check
In Tekla Structural Designer, you can choose to adopt a rigorous approach to slab deflection calculation using iterative cracked section analysis. For further details, see: Slab deflections handbook.
Create reports
To add slab design and punching shear check calculations to any model report, in the Report Contents dialog box, select the report style, then open the Concrete chapter and drag the Slab/Mat Design chapter into the report structure.

-
Slab/Mat Design per Plane: This chapter contains sub-chapters for
-
the individual slab patch designs,

the individual slab panels,

-
and punching shear checks.

Each of the above has a member report style assigned that controls the level of output produced.
-
-
Slab/Mat Design Summary: By default, this chapter summarizes all the slab panel and patch designs, and punching shear checks in the model. It can be filtered as required.

The style can be selected for each sub-chapter of the report from the right-click context menu as shown below.

- Close the above dialog box and open the Member Reports dialog box.
- Choose the member types in turn (for example, Punching Check, Slab/Mat Panel, Slab/Mat Patch) and select an existing style (or add a new one if required).
- Drag chapters and options into the report structure as required.Note: This dialog box is also used to review which member report style has been nominated as the "Active Style." You can switch this to the currently selected style by clicking the >> Active button.
-
Configure the level of calculation detail by right-clicking on the Design Calculations chapter and selecting Settings from the context menu.
-
Choose the level of detail that the calculations are to be expanded to in the report (critical, with no levels expanded being the minimum), then click OK to close the dialog box.
-
- Click OK to close the Member Reports dialog box.
To print the model report, on the ribbon, go to the Report tab, select the report style name, and then click Show Report.
Create drawings and quantity estimations
Drawings that convey the structural intent are easy to create. It should be borne in mind that these are not the final detail drawings; their purpose is to eliminate the need for manual mark-up drawings as a means of communication between the engineer and the detailer.
- Slab/Mat Layout: Created from the Draw tab of the ribbon by selecting Slab/Mat Detailing. This variant has pre-configured layer configurations available to limit the reinforcement displayed:
-
Slab/Mat Detail (All): This configuration displays top and bottom reinforcement and also displays punching perimeters.

-
Slab/Mat Detail (Top Reinforcement): This configuration displays top reinforcement only.

-
Slab/Mat Detail (Bottom Reinforcement): This configuration displays bottom reinforcement only.

-
Slab/Mat Detail (Punching): This configuration displays the punching perimeters on the layout and also includes separate details of any stud rail reinforcement that has been designed.


-
-
Punching Check Detail: This variant can be created by right-clicking on an individual punching check item in a scene view and selecting Generate Drawing from the context menu.