The following terms are relevant when using Tekla Structural Designer to design to the Eurocodes.
National Annex (NA)
Safety factors in the Eurocodes are recommended values and may be altered by the national annex of each member state.
In addition to the base Eurocode, Tekla Structural Designer currently has the following national annex options available:
-
Finland
-
Ireland
-
Malaysia
-
Norway
-
Singapore
-
Sweden
-
UK
You can select the desired National Annex as appropriate, in which case the nationally determined parameters are automatically applied (see next section), or if you choose EC3 Europe, the Eurocode recommended values are applied.
Nationally Determined Parameters (NDP’s)
NDP’s are choices of values, classes or alternative methods contained in a National Annex that can be applied in place of the base Eurocode, EC3 Europe.
Partial Factors for Buildings
The partial factors γM for buildings as described in clause 6.1(1) Note 2B should be applied to the various characteristic values of resistance as follows:
-
resistance of cross-sections irrespective of class: γM0
-
resistance of members to instability assessed by member checks: γM1
-
resistance of cross-sections in tension to fracture: γM2
Depending on your choice of National Annex the above partial factors for buildings are set as follows:
| Factor | EC3 Base value | UK | Ireland | Malaysia | Singapore |
|---|---|---|---|---|---|
| γM0 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
| γM1 | 1.00 | 1.00 | 1.00 | 1.00 | 1.00 |
| γM2 | 1.25 | 1.10* | 1.25 | 1.20 | 1.10 |
NOTE - for connection design BS EN1991-1-8 - γM2 = 1.25