Graphically set the members/ancillaries/equipment to which open structure wind loading applies from a Review View using the Show/Alter State command Wind Loading attribute.
-
Open a view and switch the view
regime to
Review View.
- On the Review ribbon, click Show/Alter State.
- Go to the Properties window.
- In the Attribute list, ensure that Wind Loading is selected.
- If you want to apply the setting to individual stacks/spans within members as opposed to the entire member, unselect Entire member.
- Set Mode to Set On , or Set Off or Toggle.
-
In the model, click the
members/ancillaries/equipment for which you want to set the check.
- If Mode is Set On - the setting is switched on
- If Mode is Set Off - the setting is switched off
- If Mode is Toggle - the setting toggles between on and off
- Continue applying the setting or press Esc to finish.